Heat Pump List

Tools

TWH36AT19D6DO

TWH36AT19D6DO is in the certified data.

Its certified full-speed heating output at 5°F is 24,600 Btu/h, 72% of its 47°F rating (tests at different compressor speeds) in its certified pairing.

Tosot · mini-split heat pump

All 294 certified Tosot models

TWH36AT19D6DO is in the certified data as of Sep 25, 2026.

Certified heating and cooling

Heating at 47°F

34,000

22,000 at 17°F

24,600 at 5°F

Btu/h, certified

1.80 COP at 5°F

Cooling at 95°F

33,600

Btu/h, certified

EER2 10.6 at 95°F

SEER2 21.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for TWH36AT19D6DO, by outdoor temperature Heating: 24,600 Btu/h at 5°F, 22,000 Btu/h at 17°F, 34,000 Btu/h at 47°F. Cooling: 33,600 Btu/h at 95°F. The bars start at zero. Median of 3-ton mini-split models: 31,000 Btu/h at 5°F, 29,600 Btu/h at 17°F, 37,000 Btu/h at 47°F, 36,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 24,600 5°F 22,000 17°F 34,000 47°F 33,600 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 34,000 Btu/h of heat at 47°F, 22,000 Btu/h at 17°F, and 24,600 Btu/h at 5°F, 72% of its 47°F rating. It delivers 33,600 Btu/h of cooling at 95°F. At 5°F that is 6,400 Btu/h short of the example heating load of 31,000 Btu/h; at 95°F it is 18,100 Btu/h above the example cooling load of 15,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,300 sq ft where winters reach 5°F: heating runs from 31,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 15,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 216768205 · listed by TOSOT · certified Sep 23, 2026 · 1 pairing carries these values

Rebates where you live

Meets the recorded equipment thresholds of 47 programs in 29 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Connecticut (3), Delaware (1), Idaho (2), Kentucky (1), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (2), Mississippi (2), New Hampshire (2), New Jersey (2), New York (4), Oregon (2), Rhode Island (3), Tennessee (1), Utah (1), Vermont (3), Washington (1), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 47 programs by state and province

Alabama

Arizona

California

Connecticut

Delaware

Idaho

Kentucky

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

New Hampshire

New Jersey

New York

Oregon

Rhode Island

Tennessee

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 24,6007.21 kW −21% 1.80
17°Ffull speed 22,0006.45 kW −26% NR
47°Fnormal speed 34,0009.96 kW −8% NR
95°Fcooling, full load 33,6009.85 kW — NR

EER2 10.6 in that test. SEER2 21.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
4.01kW
Electrical input in the 95°F cooling test
3.17kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 25, 2026 · Methodology

How it compares with other 36,000 Btu heat pumps

3-ton mini-split models

This pairing at 5°F
24,600 Btu/h
This unit at 5°F median across its pairings
24,600 Btu/h
Median of 3-ton mini-split models at 5°F
31,000 Btu/h
Models in this group
553

This unit is above 12% of them, at number 489 of 553 by heat at 5°F. The middle half of the group runs 26,000 to 36,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 36,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 325th of 551 (tied); HSPF2, 512th of 553 (tied). Models without that figure are left out.

Similar ratings at 47°F

These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • 4MXT36AVJU: The same 34,000 Btu/h rating at 47°F; 31,800 Btu/h at 5°F (this model: 24,600).
  • LISH036202U332: The same 34,000 Btu/h rating at 47°F; 22,000 Btu/h at 5°F (this model: 24,600).
  • ESHBA36C2AN: The same 34,000 Btu/h rating at 47°F; HSPF2 9.1 (this model: 8.5).

Closest models by heat at 5°F

Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 24,600 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42590–1,030
MildTypical16–26950–1,540
MildTight, well insulated10–181,370–2,460
ColdDrafty, little insulation28–52470–880
ColdTypical18–30820–1,370
ColdTight, well insulated12–221,120–2,050
Very coldDrafty, little insulation32–58420–770
Very coldTypical22–38650–1,120
Very coldTight, well insulated16–28880–1,540

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for TWH36AT19D6DO

1 pairing · 1 AHRI certificate

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for TWH36AT19D6DO
This pairingAll pairings
Heating
Heat output at 47°F normal speed 34,000 Btu/h 34,000 Btu/h
Heat output at 17°F full speed 22,000 Btu/h 22,000 Btu/h
Heat output at 5°F full speed 24,600 Btu/h 24,600 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 72%
COP at 5°F full speed 1.80 1.80
HSPF2 Region IV 8.5 8.5
Cooling
Cooling capacity at 95°F full-load test 33,600 Btu/h 33,600 Btu/h
EER2 at 95°F 10.6 10.6
SEER2 cooling season 21.0 21.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-32
Compressor Variable speed
Indoor unit TWH36AT19D6DI 1 indoor unit
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified TWH36AT19D6DO

Pairings, by indoor-unit class

1 indoor unit · 1 certified pairing

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 1 indoor unit

  1. TWH36AT19D6DI (the pairing on screen) TOSOT 24,600 Btu/hat 5°F, full speed

    1 pairing · 47°F 34,000 Btu/h · 95°F cooling 33,600 Btu/h · Cold output 72% · COP 1.80

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
TWH36AT19D6DI (the pairing on screen) TOSOT 24,600 34,000 33,600 72% 1.80 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 1 of 1 indoor unit

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

History and definitions

Other Tosot standard Level Series models by nominal cooling size: TWH30AT19D6DO (30,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Sep 23, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “TWH36AT19D6DO — certified heat output”. Certified figures dated , checked daily.