VPD060S6M-5P
VPD060S6M-5P is in the certified data.
Its certified full-speed heating output at 5°F is 47,000 Btu/h13.77 kW, 71% of its 47°F rating (tests at different compressor speeds) across its certified pairings.
Lennox · mini-split heat pump
VPD060S6M-5P is in the certified data as of Sep 19, 2026. VPD060S6M-5P changed its certified heat output at 47°F on 2 pairings from 60,000 Btu/h to 66,000 Btu/h in the certified data between August 2025 and September 2026.
- 60,000 Btu (5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
66,00019.34NR
No 47°F rating for this pairing.
43,00012.60NR at 17°F
47,00013.77NR at 5°F
Btu/hkW, certified
2.15NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 66,000 Btu/h19.34 kW of heat at 47°F, 43,000 Btu/h12.60 kW at 17°F, and 47,000 Btu/h13.77 kW at 5°F, 71% of its 47°F rating. It delivers 60,000 Btu/h17.58 kW of cooling at 95°F. At 5°F that is 500 Btu/h0.15 kW above the example heating load of 46,500 Btu/h13.63 kW; at 95°F it is 36,500 Btu/h10.70 kW above the example cooling load of 23,500 Btu/h6.89 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,950 sq ft where winters reach 5°F: heating runs from 46,500 Btu/h13.63 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 23,500 Btu/h6.89 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217169772 · listed by Lennox · certified Mar 26, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 47,00013.77 kW | +1% | 2.15 | |
| 17°Ffull speed | 43,00012.60 kW | +4% | NR | |
| 47°Fnormal speed | 66,00019.34 kW | +2% | NR | |
| 95°Fcooling, full load | 60,00017.58 kW | — | NR |
EER2 11.0 in that test. SEER2 18.25 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 6.41kW
- Electrical input in the 95°F cooling test
- 5.45kW
- Seasonal average heating COP
- 2.89
These exclude backup resistance heat.
How it compares with other 60,000 Btu heat pumps
5-ton mini-split models
- This pairing at 5°F
- 47,000 Btu/h13.77 kWNR
- This unit at 5°F median across its pairings
- 47,000 Btu/h13.77 kW
- Median of 5-ton mini-split models at 5°F
- 46,500 Btu/h13.63 kW
- Models in this group
- 30
This unit is above 63% of them, at number 11 of 30 by heat at 5°F. The middle half of the group runs 45,500 to 47,000 Btu/h.
Closest models by heat at 5°F
- ARUB060GSS4LG · 50,000 Btu/h
- ARUN060GSS4LG · 50,000 Btu/h
- VPD060H6M-5PLennox · 47,000 Btu/h
- AOUK060MSAN7Fujitsu · 46,500 Btu/h
- GMV-V60WL/NHC-T(U)Gree · 46,500 Btu/h
- MCY-MAP0607HS-ULToshiba Carrier · 46,500 Btu/h
Every 60,000 Btu (5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for VPD060S6M-5P
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 66,000 Btu/h19.34 kWNR | 66,000 Btu/h19.34 kW |
| Heat output at 17°F full speed | 43,000 Btu/h12.60 kWNR | 43,000 Btu/h12.60 kW |
| Heat output at 5°F full speed | 47,000 Btu/h13.77 kWNR | 47,000 Btu/h13.77 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 71%NR | |
| COP at 5°F full speed | 2.15NR | 2.10–2.20 |
| HSPF2 Region IV | 9.9NR | 9.5–10.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 60,000 Btu/h17.58 kWNR | 60,000 Btu/h17.58 kW |
| EER2 at 95°F | 11.0NR | 10.0–12.0 |
| SEER2 cooling season | 18.25NR | 16.5–20.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | VPD060S6M-5P | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) LENNOX 47,000 Btu/h13.77 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | LENNOX | 47,00013.77 | 66,00019.34 | 60,00017.58 | 71% | 2.15 | Yes | 3 |
Sold as, and units with identical certified values
Variants of the same model number
3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
Other model numbers with identical certified values
3 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- VPD060S6M-5P changed its certified heat output at 47°F on 2 pairings from 60,000 Btu/h to 66,000 Btu/h in the certified data between August 2025 and September 2026.
- VPD060S6M-5P changed its certified heat output at 47°F on AHRI certificate 216054507 from 66,000 Btu/h to 60,000 Btu/h in the certified data between March 2025 and May 2025.
- VPD060S6M-5P first appeared in the certified data between November 2024 and February 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 26, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read