YH936E2C11
YH936E2C11 is in the certified data.
Its certified full-speed heating output at 5°F is 23,000–33,600 Btu/h6.74–9.85 kW, 92–106% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
York · central heat pump
YH936E2C11 is in the certified data as of Oct 18, 2026.
- 36,000 Btu (3-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
35,00010.26NR
No 47°F rating for this pairing.
30,6008.97NR at 17°F
32,6009.55NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 35,000 Btu/h10.26 kW of heat at 47°F, 30,600 Btu/h8.97 kW at 17°F, and 32,600 Btu/h9.55 kW at 5°F, 93% of its 47°F rating. It delivers 35,200 Btu/h10.32 kW of cooling at 95°F. At 5°F that is 6,100 Btu/h1.79 kW above the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 22,200 Btu/h6.51 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218026623 · listed by York · certified Aug 20, 2026 · 21 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 32,6009.55 kW | +23% | 2.00 | |
| 17°Ffull speed | 30,6008.97 kW | +17% | NR | |
| 47°Fnormal speed | 35,00010.26 kW | −1% | NR | |
| 95°Fcooling, full load | 35,20010.32 kW | — | NR |
EER2 11.0 in that test. SEER2 18.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.78kW
- Electrical input in the 95°F cooling test
- 3.20kW
- Seasonal average heating COP
- 2.78
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 32,600 Btu/h9.55 kWNR
- This unit at 5°F median across its pairings
- 32,600 Btu/h9.55 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 77% of them, at number 105 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- CH-PQ36-230VOCooper&Hunter · 32,600 Btu/h
- GZV9SA361CAGoodman · 32,600 Btu/h
- KEENULDHP36AAKEEN Home · 32,600 Btu/h
- BZ33-INV36OUT2-JBreeze33 · 32,000 Btu/h
- DLCURAH36ABKAirquest, Arcoaire + 12 more · 32,000 Btu/h
- ECUO-33HEco Air · 32,000 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YH936E2C11
207 pairings · 207 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 35,000 Btu/h10.26 kWNR | 23,000–35,000 Btu/h6.74–10.26 kW |
| Heat output at 17°F full speed | 30,600 Btu/h8.97 kWNR | 25,600–31,400 Btu/h7.50–9.20 kW |
| Heat output at 5°F full speed | 32,600 Btu/h9.55 kWNR | 23,000–33,600 Btu/h6.74–9.85 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 93%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 9.5NR | 9.0–9.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 35,200 Btu/h10.32 kWNR | 23,000–35,600 Btu/h6.74–10.43 kW |
| EER2 at 95°F | 11.0NR | 10.0–13.0 |
| SEER2 cooling season | 18.0NR | 17.0–19.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | CTM36C5ADS1+CC | 27 indoor units |
| Furnace | Y92V100C20SMPC1 | 42 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | YH936E2C11 | |
Pairings, by indoor-unit class
27 indoor units · 207 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 10 indoor units
-
CTF36C5ADS1+CC (the pairing on screen) brand not stated 32,800 Btu/h9.61 kWat 5°F, full speed
-
CTM36C5ADS1+CC (the pairing on screen) brand not stated 32,800 Btu/h9.61 kWat 5°F, full speed
-
CTM36C5ADS2+CC (the pairing on screen) brand not stated 32,700 Btu/h9.58 kWat 5°F, full speed
-
CTF36C5ADS2+CC (the pairing on screen) brand not stated 32,800 Btu/h9.61 kWat 5°F, full speed
-
CTF30B5ACS1+CC (the pairing on screen) brand not stated 24,600 Btu/h7.21 kWat 5°F, full speed
-
CTF36B5ADS1+CC (the pairing on screen) brand not stated 33,300 Btu/h9.76 kWat 5°F, full speed
-
CTM30B5ACS1+CC (the pairing on screen) brand not stated 24,600 Btu/h7.21 kWat 5°F, full speed
-
CTM30B5ACS2+CC (the pairing on screen) brand not stated 24,600 Btu/h7.21 kWat 5°F, full speed
-
CTM36B5ADS1+CC (the pairing on screen) brand not stated 33,400 Btu/h9.79 kWat 5°F, full speed
-
CTF30B5ACS2+CC (the pairing on screen) brand not stated 24,600 Btu/h7.21 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CTF36C5ADS1+CC (the pairing on screen) | — | 32,8009.61 | 35,00010.26 | 35,00010.26 | 94% | 2.00 | Yes | 30 |
| CTM36C5ADS1+CC (the pairing on screen) | — | 32,8009.61 | 35,00010.26 | 35,00010.26 | 94% | 2.00 | Yes | 30 |
| CTM36C5ADS2+CC (the pairing on screen) | — | 32,7009.58 | 35,00010.26 | 35,20010.32 | 93% | 2.00 | Yes | 24 |
| CTF36C5ADS2+CC (the pairing on screen) | — | 32,8009.61 | 35,00010.26 | 35,00010.26 | 94% | 2.00 | Yes | 20 |
| CTF30B5ACS1+CC (the pairing on screen) | — | 24,6007.21 | 23,2006.80 | 23,0006.74 | 106% | 2.00 | Yes | 12 |
| CTF36B5ADS1+CC (the pairing on screen) | — | 33,3009.76 | 35,00010.26 | 34,60010.14 | 95% | 2.00 | Yes | 12 |
| CTM30B5ACS1+CC (the pairing on screen) | — | 24,6007.21 | 23,2006.80 | 23,0006.74 | 106% | 2.00 | Yes | 12 |
| CTM30B5ACS2+CC (the pairing on screen) | — | 24,6007.21 | 23,2006.80 | 23,0006.74 | 106% | 2.00 | Yes | 12 |
| CTM36B5ADS1+CC (the pairing on screen) | — | 33,4009.79 | 35,00010.26 | 34,50010.11 | 95% | 2.00 | Yes | 12 |
| CTF30B5ACS2+CC (the pairing on screen) | — | 24,6007.21 | 23,2006.80 | 23,0006.74 | 106% | 2.00 | Yes | 10 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Aug 20, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read