YN060GLSI24M6G
YN060GLSI24M6G is in the certified data.
Its certified full-speed heating output at 5°F is 41,000–42,000 Btu/h12.02–12.31 kW, 75–76% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Pioneer · mini-split heat pump
YN060GLSI24M6G is in the certified data as of Sep 19, 2026.
- 54,000 Btu (4.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
55,00016.12NR
No 47°F rating for this pairing.
51,00014.95NR at 17°F
41,00012.02NR at 5°F
Btu/hkW, certified
1.75NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 55,000 Btu/h16.12 kW of heat at 47°F, 51,000 Btu/h14.95 kW at 17°F, and 41,000 Btu/h12.02 kW at 5°F, 75% of its 47°F rating. It delivers 55,000 Btu/h16.12 kW of cooling at 95°F. At 5°F that is 6,500 Btu/h1.90 kW short of the example heating load of 47,500 Btu/h13.92 kW; at 95°F it is 31,000 Btu/h9.09 kW above the example cooling load of 24,000 Btu/h7.03 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 2,000 sq ft where winters reach 5°F: heating runs from 47,500 Btu/h13.92 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 24,000 Btu/h7.03 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218696835 · listed by Pioneer · certified Sep 1, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 41,00012.02 kW | −14% | 1.75 | |
| 17°Ffull speed | 51,00014.95 kW | +24% | NR | |
| 47°Fnormal speed | 55,00016.12 kW | 0% | NR | |
| 95°Fcooling, full load | 55,00016.12 kW | — | NR |
EER2 9.5 in that test. SEER2 18.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 6.87kW
- Electrical input in the 95°F cooling test
- 5.79kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 54,000 Btu heat pumps
4.5-ton mini-split models
- This pairing at 5°F
- 41,000 Btu/h12.02 kWNR
- This unit at 5°F median across its pairings
- 41,000 Btu/h12.02 kW
- Median of 4.5-ton mini-split models at 5°F
- 47,500 Btu/h13.92 kW
- Models in this group
- 115
This unit is above 11% of them, at number 102 of 115 by heat at 5°F. The middle half of the group runs 46,000 to 53,000 Btu/h.
Closest models by heat at 5°F
- ACIQ-55Z-HH-M5B1HVAC, ACiQ + 3 more · 46,000 Btu/h
- BMM55HHCBlueridge · 45,500 Btu/h
- URHT-55FM6N4VKIN · 42,000 Btu/h
- KUSUB601ALG · 38,500 Btu/h
- TM60D6MOTosot · 36,400 Btu/h
- GS6M60HP230V1MOGree · 32,000 Btu/h
Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YN060GLSI24M6G
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 55,000 Btu/h16.12 kWNR | 55,000 Btu/h16.12 kW |
| Heat output at 17°F full speed | 51,000 Btu/h14.95 kWNR | 48,500–51,000 Btu/h14.21–14.95 kW |
| Heat output at 5°F full speed | 41,000 Btu/h12.02 kWNR | 41,000–42,000 Btu/h12.02–12.31 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 75%NR | |
| COP at 5°F full speed | 1.75NR | 1.75–2.00 |
| HSPF2 Region IV | 9.0NR | 9.0–9.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 55,000 Btu/h16.12 kWNR | 55,000 Btu/h16.12 kW |
| EER2 at 95°F | 9.5NR | 9.5–10.0 |
| SEER2 cooling season | 18.5NR | 18.5–22.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | YN060GLSI24M6G | |
Pairings, by indoor-unit class
2 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) Pioneer 41,500 Btu/h12.16 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | Pioneer | 41,50012.16 | 55,00016.12 | 55,00016.12 | 75% | 1.88 | Yes | 2 |
Sold as, and units with identical certified values
Variants of the same model number
4 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
3 of 4 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Sep 1, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read