YPAS30BUFASDQ1
YPAS30BUFASDQ1 is in the certified data.
Its certified full-speed heating output at 5°F is 23,600–32,600 Btu/h6.92–9.55 kW, 74–102% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
York · mini-split heat pump
YPAS30BUFASDQ1 is in the certified data as of Sep 19, 2026.
- 30,000 Btu (2.5-ton)
- Mini-split
- Variable speed
- United States
Certified heating and cooling
Heating at 47°F
32,0009.38NR
No 47°F rating for this pairing.
28,0008.21NR at 17°F
31,6009.26NR at 5°F
Btu/hkW, certified
2.10NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 32,000 Btu/h9.38 kW of heat at 47°F, 28,000 Btu/h8.21 kW at 17°F, and 31,600 Btu/h9.26 kW at 5°F, 99% of its 47°F rating. It delivers 30,000 Btu/h8.79 kW of cooling at 95°F. At 5°F that is 6,600 Btu/h1.93 kW above the example heating load of 25,000 Btu/h7.33 kW; at 95°F it is 17,500 Btu/h5.13 kW above the example cooling load of 12,500 Btu/h3.66 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,050 sq ft where winters reach 5°F: heating runs from 25,000 Btu/h7.33 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 12,500 Btu/h3.66 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218694240 · listed by York · certified Aug 11, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 31,6009.26 kW | +26% | 2.10 | |
| 17°Ffull speed | 28,0008.21 kW | +9% | NR | |
| 47°Fnormal speed | 32,0009.38 kW | +7% | NR | |
| 95°Fcooling, full load | 30,0008.79 kW | — | NR |
EER2 13.0 in that test. SEER2 19.6 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.41kW
- Electrical input in the 95°F cooling test
- 2.31kW
- Seasonal average heating COP
- 3.17
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton mini-split models
- This pairing at 5°F
- 31,600 Btu/h9.26 kWNR
- This unit at 5°F median across its pairings
- 31,600 Btu/h9.26 kW
- Median of 2.5-ton mini-split models at 5°F
- 25,000 Btu/h7.33 kW
- Models in this group
- 405
This unit is above 80% of them, at number 79 of 405 by heat at 5°F. The middle half of the group runs 20,000 to 27,000 Btu/h.
Closest models by heat at 5°F
- TRUZH0301KA00Trane / Mitsubishi Electric · 32,000 Btu/h
- TRUZH0301KA00NATrane / Mitsubishi Electric · 32,000 Btu/h
- YPAS30BLFASDQ1York · 31,800 Btu/h
- AOU30RLXEHFujitsu · 30,400 Btu/h
- 37VMB030HDS3-1Carrier · 30,000 Btu/h
- MMLD030S6M-1PLennox · 28,600 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YPAS30BUFASDQ1
5 pairings · 5 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 32,000 Btu/h9.38 kWNR | 32,000 Btu/h9.38 kW |
| Heat output at 17°F full speed | 28,000 Btu/h8.21 kWNR | 26,600–29,000 Btu/h7.80–8.50 kW |
| Heat output at 5°F full speed | 31,600 Btu/h9.26 kWNR | 23,600–32,600 Btu/h6.92–9.55 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 99%NR | |
| COP at 5°F full speed | 2.10NR | 2.10–2.50 |
| HSPF2 Region IV | 10.8NR | 10.0–12.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 30,000 Btu/h8.79 kWNR | 28,000–30,000 Btu/h8.21–8.79 kW |
| EER2 at 95°F | 13.0NR | 11.7–14.0 |
| SEER2 cooling season | 19.6NR | 16.0–21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | YPPIMB30UFA1DQ | 5 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | United States | United States |
| Model string as certified | YPAS30BUFASDQ1 | |
Pairings, by indoor-unit class
5 indoor units · 5 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 5 indoor units
-
JPE30B3XD2HS2 (the pairing on screen) YORK 23,600 Btu/h6.92 kWat 5°F, full speed
-
YPCIB30UFA1DQ (the pairing on screen) YORK 32,600 Btu/h9.55 kWat 5°F, full speed
-
YPPFCB30UFA1DQ (the pairing on screen) YORK 24,200 Btu/h7.09 kWat 5°F, full speed
-
YPPIMB30UFA1DQ (the pairing on screen) YORK 31,600 Btu/h9.26 kWat 5°F, full speed
-
YPPKB30UFA1DQ (the pairing on screen) YORK 31,800 Btu/h9.32 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| JPE30B3XD2HS2 (the pairing on screen) | YORK | 23,6006.92 | 32,0009.38 | 28,0008.21 | 74% | 2.30 | Yes | 1 |
| YPCIB30UFA1DQ (the pairing on screen) | YORK | 32,6009.55 | 32,0009.38 | 30,0008.79 | 102% | 2.30 | Yes | 1 |
| YPPFCB30UFA1DQ (the pairing on screen) | YORK | 24,2007.09 | 32,0009.38 | 30,0008.79 | 76% | 2.50 | Yes | 1 |
| YPPIMB30UFA1DQ (the pairing on screen) | YORK | 31,6009.26 | 32,0009.38 | 30,0008.79 | 99% | 2.10 | Yes | 1 |
| YPPKB30UFA1DQ (the pairing on screen) | YORK | 31,8009.32 | 32,0009.38 | 30,0008.79 | 99% | 2.10 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Aug 11, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read