Heat Pump List

Tools

Bryant heat pumps · page 2

205 certified models, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2), highest first.

Filters

Filters Bryant

The list

  1. 201 675ENWB36****A*Bryant
    34,400 Btu/hheating at 47°F 35,200 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 14,100 Btu/h · Cold output 41% · HSPF2 7.2 · 1 pairing

  2. 202 607ENXK24000AABryant
    23,800 Btu/hheating at 47°F 22,400 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 8,600 Btu/h · Cold output 36% · HSPF2 7.2 · 1 pairing

  3. 203 677ENWK24****A*Bryant
    23,800 Btu/hheating at 47°F 22,400 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 8,600 Btu/h · Cold output 36% · HSPF2 7.2 · 1 pairing

  4. 204 605ENXB24000AABryant
    23,400 Btu/hheating at 47°F 22,200 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 8,400 Btu/h · Cold output 36% · HSPF2 7.2 · 1 pairing

  5. 205 675ENWB24****A*Bryant
    23,400 Btu/hheating at 47°F 22,200 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 8,400 Btu/h · Cold output 36% · HSPF2 7.2 · 1 pairing

Bryant heat pumps, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2)
# Model Brands Type Size At 5°FBtu/h · heating At 47°FBtu/h · heating At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed SEER2median pairing HSPF2Btu/Wh · median pairing Compressor Refrigerant Market Pairings
201 675ENWB36****A* Bryant Central 36,000 Btu (3-ton)14,100 34,400 35,200 41% 1.70 15.2 7.2 2-stage R-454B US CA 1
202 607ENXK24000AA Bryant Central 24,000 Btu (2-ton)8,600 23,800 22,400 36% 1.90 15.2 7.2 2-stage R-410A US CA 1
203 677ENWK24****A* Bryant Central 24,000 Btu (2-ton)8,600 23,800 22,400 36% 1.90 15.2 7.2 2-stage R-410A US CA 1
204 605ENXB24000AA Bryant Central 24,000 Btu (2-ton)8,400 23,400 22,200 36% 1.60 15.2 7.2 2-stage R-454B US CA 1
205 675ENWB24****A* Bryant Central 24,000 Btu (2-ton)8,400 23,400 22,200 36% 1.60 15.2 7.2 2-stage R-454B US CA 1

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

5 of 205 units · page 2 of 2

Other sizes

Every size class, with how many units it holds and its median heat output at 5°F