Heat Pump List

Tools

EG4 heat pumps

15 certified models, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2), highest first.

Filters

Filters EG4

The list

  1. 1 DWA4-09KDeye, EG4
    9,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F NR · Cold output — · HSPF2 9.8 · 2 pairings

  2. 2 DWA4-12KDeye, EG4
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F NR · Cold output — · HSPF2 9.7 · 2 pairings

  3. 3 DWA4-09KR2(US)Airspool, Deye, EG4
    9,500 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F NR · Cold output — · HSPF2 10.5 · 3 pairings

  4. 4 DW4E1-ACDC-36KR2(US)Airspool, Deye, EG4
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 29,000 Btu/h · Cold output 81% · HSPF2 10.0 · 3 pairings

  5. 5 DWA4-12KR2(US)Airspool, Deye + 2 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F NR · Cold output — · HSPF2 9.7 · 4 pairings

  6. 6 DWA4-ACDC1-12KR2(US)Airspool, Deye + 2 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F NR · Cold output — · HSPF2 9.7 · 4 pairings

  7. 7 DW3B1-ACDC-24KR2(US)Airspool, Deye + 2 more
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 19,000 Btu/h · Cold output 79% · HSPF2 10.0 · 4 pairings

  8. 8 DWA4-ACDC1-12KAirspool, Deye, EG4
    12,000 Btu/hheating at 47°F 11,600 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F NR · Cold output — · HSPF2 9.5 · 3 pairings

  9. 9 DWLA4-12KR2(US)Airspool, Deye + 2 more
    13,500 Btu/hheating at 47°F 11,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 10,000 Btu/h · Cold output 74% · HSPF2 10.8 · 4 pairings

  10. 10 DWLA4-ACDC1-12KR2(US)Airspool, Deye + 2 more
    13,500 Btu/hheating at 47°F 11,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 10,000 Btu/h · Cold output 74% · HSPF2 10.8 · 4 pairings

  11. 11 DWLC2-24KR2(US)Airspool, Deye + 2 more
    27,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 22,000 Btu/h · Cold output 81% · HSPF2 11.0 · 4 pairings

  12. 12 DWLC2-ACDC-24KR2(US)Airspool, Deye + 2 more
    27,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 22,000 Btu/h · Cold output 81% · HSPF2 11.0 · 4 pairings

  13. 13 DWB3-ACDC-24KR2(US)Airspool, Deye + 2 more
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 17,500 Btu/h · Cold output 73% · HSPF2 10.0 · 4 pairings

  14. 14 DWA5-ACDC-18KR2(US)Airspool, Deye + 2 more
    17,000 Btu/hheating at 47°F 17,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,600 Btu/h · Cold output 74% · HSPF2 9.8 · 4 pairings

  15. 15 DWB3-ACDC-24KDeye, EG4
    25,000 Btu/hheating at 47°F 22,600 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 17,500 Btu/h · Cold output 70% · HSPF2 9.6 · 2 pairings

EG4 heat pumps, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2)
# Model Brands Type Size At 5°FBtu/h · heating At 47°FBtu/h · heating At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed SEER2median pairing HSPF2Btu/Wh · median pairing Compressor Refrigerant Market Pairings
1 DWA4-09K Deye, EG4 Mini-split 9,000 Btu— 9,000 9,000 — — 29.0 9.8 Variable R-410A US 2
2 DWA4-12K Deye, EG4 Mini-split 12,000 Btu (1-ton)— 12,000 12,000 — — 28.0 9.7 Variable R-410A US 2
3 DWA4-09KR2(US) Airspool, Deye, EG4 Mini-split 9,000 Btu— 9,500 9,000 — — 25.0 10.5 Variable R-32 US 3
4 DW4E1-ACDC-36KR2(US) Airspool, Deye, EG4 Mini-split 36,000 Btu (3-ton)29,000 36,000 36,000 81% 2.23 22.5 10.0 Variable R-32 US CA 3
5 DWA4-12KR2(US) Airspool, Deye + 2 more Mini-split 12,000 Btu (1-ton)— 12,000 12,000 — — 22.5 9.7 Variable R-32 US 4
6 DWA4-ACDC1-12KR2(US) Airspool, Deye + 2 more Mini-split 12,000 Btu (1-ton)— 12,000 12,000 — — 22.5 9.7 Variable R-32 US 4
7 DW3B1-ACDC-24KR2(US) Airspool, Deye + 2 more Mini-split 24,000 Btu (2-ton)19,000 24,000 24,000 79% 2.14 22.0 10.0 Variable R-32 US CA 4
8 DWA4-ACDC1-12K Airspool, Deye, EG4 Mini-split 12,000 Btu (1-ton)— 12,000 11,600 — — 22.0 9.5 Variable R-410A US 3
9 DWLA4-12KR2(US) Airspool, Deye + 2 more Mini-split 12,000 Btu (1-ton)10,000 13,500 11,000 74% 2.05 21.5 10.8 Variable R-32 US CA 4
10 DWLA4-ACDC1-12KR2(US) Airspool, Deye + 2 more Mini-split 12,000 Btu (1-ton)10,000 13,500 11,000 74% 2.05 21.5 10.8 Variable R-32 US CA 4
11 DWLC2-24KR2(US) Airspool, Deye + 2 more Mini-split 24,000 Btu (2-ton)22,000 27,000 22,000 81% 2.05 21.0 11.0 Variable R-32 US CA 4
12 DWLC2-ACDC-24KR2(US) Airspool, Deye + 2 more Mini-split 24,000 Btu (2-ton)22,000 27,000 22,000 81% 2.05 21.0 11.0 Variable R-32 US CA 4
13 DWB3-ACDC-24KR2(US) Airspool, Deye + 2 more Mini-split 24,000 Btu (2-ton)17,500 24,000 24,000 73% 2.15 21.0 10.0 Variable R-32 US CA 4
14 DWA5-ACDC-18KR2(US) Airspool, Deye + 2 more Mini-split 18,000 Btu (1.5-ton)12,600 17,000 17,000 74% 2.15 21.0 9.8 Variable R-32 US 4
15 DWB3-ACDC-24K Deye, EG4 Mini-split 24,000 Btu (2-ton)17,500 25,000 22,600 70% 1.80 21.0 9.6 Variable R-410A US 2

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

15 of 15 units

Other sizes

Every size class, with how many units it holds and its median heat output at 5°F