Heat Pump List

Tools

DWA4-12K

DWA4-12K is in the certified data.

Its certified ratings are 9.7 HSPF2 and 28.0 SEER2.

Deye and EG4 · mini-split heat pump

All 16 certified Deye models · All 15 certified EG4 models

DWA4-12K is in the certified data as of Sep 19, 2026.

Certified heating and cooling

Heating at 47°F

12,000

10,200 at 17°F

NR at 5°F

Btu/h, certified

NR COP at 5°F

Cooling at 95°F

12,000

Btu/h, certified

EER2 12.5 at 95°F

SEER2 28.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for DWA4-12K, by outdoor temperature Heating: no certified figure at 5°F, 10,200 Btu/h at 17°F, 12,000 Btu/h at 47°F. Cooling: 12,000 Btu/h at 95°F. The bars start at zero. Median of 1-ton mini-split models: 9,200 Btu/h at 5°F, 9,800 Btu/h at 17°F, 12,000 Btu/h at 47°F, 12,000 Btu/h at 95°F. 0 2,500 5,000 7,500 10,000 12,500 Btu/h NR 5°F 10,200 17°F 12,000 47°F 12,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 1-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 12,000 Btu/h of heat at 47°F and 10,200 Btu/h at 17°F. It delivers 12,000 Btu/h of cooling at 95°F. At 95°F that is 7,000 Btu/h above the example cooling load of 5,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 400 sq ft where winters reach 5°F: heating runs from 9,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 211765306 · listed by Deye · certified Aug 28, 2023 · 2 pairings on 2 certificates share these values

Rebates where you live

Meets the recorded equipment thresholds of 31 programs in 21 states, provinces, or territories:Alabama (1), Arizona (1), California (2), Colorado (1), Delaware (2), Idaho (2), Illinois (1), Kentucky (1), Maryland (3), Michigan (2), Minnesota (1), Mississippi (2), Nevada (1), New Jersey (4), Oregon (2), Pennsylvania (4), Tennessee (1), Texas (2), Utah (1), Washington (1), Wisconsin (1).

All 31 programs by state and province

Alabama

Arizona

California

Colorado

Delaware

Idaho

Illinois

Kentucky

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Jersey

Oregon

Pennsylvania

Tennessee

Texas

Utah

Washington

Wisconsin

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 1-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed NR NR NR
17°Ffull speed 10,2002.99 kW +4% NR
47°Fnormal speed 12,0003.52 kW 0% NR
95°Fcooling, full load 12,0003.52 kW — NR

EER2 12.5 in that test. SEER2 28.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
NRkW
Electrical input in the 95°F cooling test
0.96kW
Seasonal average heating COP
2.84

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 12,000 Btu heat pumps

1-ton mini-split models

This pairing at 5°F
NR
This unit at 5°F median across its pairings
NR
Median of 1-ton mini-split models at 5°F
9,200 Btu/h
Models in this group
888

This size class is defined by cooling capacity, so cooling is not compared here.

Among 12,000 Btu mini-split models, each by its median certified pairing, highest first: HSPF2, 532nd of 895 (tied). Models without that figure are left out.

Similar ratings at 47°F

These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • MSH123G26MCAA: The same 12,000 Btu/h rating at 47°F; HSPF2 14.5 (this model: 9.7).
  • AOUG12LZAS1: The same 12,000 Btu/h rating at 47°F; HSPF2 12.9 (this model: 9.7).
  • 38MPRBQ12AA3: The same 12,000 Btu/h rating at 47°F; HSPF2 12.0 (this model: 9.7).

Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for DWA4-12K

2 pairings · 2 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for DWA4-12K
This pairingAll pairings
Heating
Heat output at 47°F normal speed 12,000 Btu/h 12,000 Btu/h
Heat output at 17°F full speed 10,200 Btu/h 10,200 Btu/h
Heat output at 5°F full speed NR NR
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating NR NR
COP at 5°F full speed NR —
HSPF2 Region IV 9.7 9.7
Cooling
Cooling capacity at 95°F full-load test 12,000 Btu/h 12,000 Btu/h
EER2 at 95°F 12.5 12.5
SEER2 cooling season 28.0 28.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit DGA3-12K 1 indoor unit
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold United States United States
Model string as certified DWA4-12K

Pairings, by indoor-unit class

1 indoor unit · 2 certified pairings

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 1 indoor unit

  1. DGA3-12K (the pairing on screen) Deye NRat 5°F, full speed

    2 pairings · 47°F 12,000 Btu/h · 95°F cooling 12,000 Btu/h · Cold output NR · COP —

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
DGA3-12K (the pairing on screen) Deye NR 12,000 12,000 NR — NC 2

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

Showing 1 of 1 indoor unit

Sold as, and units with identical certified values

Brands listing this model number

Other brands that list these model numbers

Model number as listed

History and definitions

Other GALAXY models by nominal cooling size: DWA4-09K (9,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Aug 28, 2023
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “DWA4-12K — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/dwa4-12k