Heat Pump List

Tools

Kinghome heat pumps

97 certified models, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2), highest first.

Filters

Filters Kinghome

The list

  1. 1 KW12XQ29*DOKinghome
    12,200 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 12,200 Btu/h · Cold output 100% · HSPF2 10.0 · 1 pairing

  2. 2 KW12XQ29SDOKinghome
    12,200 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 12,200 Btu/h · Cold output 100% · HSPF2 10.0 · 1 pairing

  3. 3 KW18XQ29SDOKinghome
    18,600 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 97% · HSPF2 10.0 · 1 pairing

  4. 4 KW09HQ3D6DOKinghome
    9,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 13,000 Btu/h · Cold output 144% · HSPF2 11.0 · 1 pairing

  5. 5 KW09XQ25PAOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 9,500 Btu/h · Cold output 95% · HSPF2 10.5 · 1 pairing

  6. 6 KW09XQ25S1AOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 9,500 Btu/h · Cold output 95% · HSPF2 10.5 · 1 pairing

  7. 7 KW09XQ25SAOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 9,500 Btu/h · Cold output 95% · HSPF2 10.5 · 1 pairing

  8. 8 KW24XQ29SDOKinghome
    24,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 24,000 Btu/h · Cold output 100% · HSPF2 10.0 · 1 pairing

  9. 9 KW09HQ25SAOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 9,900 Btu/h · Cold output 99% · HSPF2 10.0 · 1 pairing

  10. 10 KWP09R32C3OKinghome
    10,500 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 12,000 Btu/h · Cold output 114% · HSPF2 10.6 · 1 pairing

  11. 11 KW09XQ25PDOKinghome
    10,500 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 9,500 Btu/h · Cold output 90% · HSPF2 10.4 · 1 pairing

  12. 12 KW09XQ25S1DOKinghome
    10,500 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 9,500 Btu/h · Cold output 90% · HSPF2 10.4 · 1 pairing

  13. 13 KW24XQ25PDOKinghome
    24,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 19,000 Btu/h · Cold output 79% · HSPF2 10.0 · 1 pairing

  14. 14 KW09HQ25SDOKinghome
    10,500 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 9,100 Btu/h · Cold output 87% · HSPF2 10.2 · 1 pairing

  15. 15 KWP12R32C3OKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 13,700 Btu/h · Cold output 114% · HSPF2 10.0 · 1 pairing

  16. 16 KWP24R32C3OKinghome
    24,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 20,400 Btu/h · Cold output 85% · HSPF2 9.5 · 1 pairing

  17. 17 KW24HQ25SDOKinghome
    24,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 17,000 Btu/h · Cold output 71% · HSPF2 9.5 · 1 pairing

  18. 18 KWP18R32C3OKinghome
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 16,500 Btu/h · Cold output 92% · HSPF2 9.5 · 1 pairing

  19. 19 KW12XQ25*1DOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 11,000 Btu/h · Cold output 92% · HSPF2 9.5 · 1 pairing

  20. 20 KW12XQ25PDOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 11,000 Btu/h · Cold output 92% · HSPF2 9.5 · 1 pairing

  21. 21 KW12XQ25S1DOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 11,000 Btu/h · Cold output 92% · HSPF2 9.5 · 1 pairing

  22. 22 KW12XQ25PAOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 9,500 Btu/h · Cold output 79% · HSPF2 9.5 · 1 pairing

  23. 23 KW12XQ25S1AOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 9,500 Btu/h · Cold output 79% · HSPF2 9.5 · 1 pairing

  24. 24 KW12XQ25SAOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 9,500 Btu/h · Cold output 79% · HSPF2 9.5 · 1 pairing

  25. 25 KW18XQ25PDOKinghome
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 14,600 Btu/h · Cold output 81% · HSPF2 9.0 · 1 pairing

  26. 26 KW18XQ25SDOKinghome
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 14,600 Btu/h · Cold output 81% · HSPF2 9.0 · 1 pairing

  27. 27 KW12HQ25SDOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 9,000 Btu/h · Cold output 75% · HSPF2 9.0 · 1 pairing

  28. 28 KW12HQ25SAOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,800 Btu/h · Cold output 73% · HSPF2 9.0 · 1 pairing

  29. 29 KW12HQ3D6DOKinghome
    12,200 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 12,000 Btu/h · Cold output 98% · HSPF2 8.5 · 1 pairing

  30. 30 KW09XQ29S1DOKinghome
    10,500 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 9,200 Btu/h · Cold output 81–108% · HSPF2 9.5 · 6 pairings

  31. 31 KW09XQ29SDOKinghome
    10,500 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 9,200 Btu/h · Cold output 81–108% · HSPF2 9.5 · 6 pairings

  32. 32 KW09XQ25SDOKinghome
    10,500 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 9,400 Btu/h · Cold output 72–95% · HSPF2 9.5 · 6 pairings

  33. 33 KW24XQ25SDOKinghome
    23,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 78% · HSPF2 9.0 · 1 pairing

  34. 34 KW18HP25SDOKinghome
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 13,500 Btu/h · Cold output 75% · HSPF2 9.0 · 1 pairing

  35. 35 KW24XQ29S1DOKinghome
    24,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 21,000 Btu/h · Cold output 71–100% · HSPF2 9.3 · 4 pairings

  36. 36 KW12XQ25SDOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 10,000 Btu/h · Cold output 83–92% · HSPF2 9.3 · 6 pairings

  37. 37 KUV-36UHOGree, Kinghome
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 25,200 Btu/h · Cold output 70% · HSPF2 9.0 · 3 pairings

  38. 38 KW12XQ29S1DOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 10,000 Btu/h · Cold output 83–100% · HSPF2 8.8 · 6 pairings

  39. 39 KW18HQ25SDOKinghome
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 13,400 Btu/h · Cold output 74% · HSPF2 8.5 · 1 pairing

  40. 40 KW18HQ3D6DOKinghome
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 20,000 Btu/h · Cold output 111% · HSPF2 10.0 · 1 pairing

  41. 41 KW18XQ29S1DOKinghome
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 17,000 Btu/h · Cold output 77–97% · HSPF2 9.2 · 7 pairings

  42. 42 KW18XQ25S1DOKinghome
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 14,600 Btu/h · Cold output 70–88% · HSPF2 9.0 · 4 pairings

  43. 43 KW30XQ21CDOKinghome
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 21,000 Btu/h · Cold output 68–77% · HSPF2 8.5 · 3 pairings

  44. 44 KW24HQ3D6DOKinghome
    24,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 24,000 Btu/h · Cold output 100% · HSPF2 9.5 · 1 pairing

  45. 45 KW24XQ25S1DOKinghome
    23,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 78–82% · HSPF2 9.0 · 2 pairings

  46. 46 KM18H5O3Kinghome
    19,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 13,500 Btu/h · Cold output 71–72% · HSPF2 9.0 · 3 pairings

  47. 47 KW36XQ21SDOKinghome
    34,000 Btu/hheating at 47°F 33,600 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 23,600 Btu/h · Cold output 69% · HSPF2 8.5 · 1 pairing

  48. 48 KW09HQ19CAOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,600 Btu/h · Cold output 76% · HSPF2 8.8 · 1 pairing

  49. 49 KW09HQ19CDOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,600 Btu/h · Cold output 76% · HSPF2 8.8 · 1 pairing

  50. 50 KW09XQ19CAOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,600 Btu/h · Cold output 76% · HSPF2 8.8 · 1 pairing

  51. 51 KW09XQ19CDOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,600 Btu/h · Cold output 76% · HSPF2 8.8 · 1 pairing

  52. 52 KW09XQ19SAOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,600 Btu/h · Cold output 76% · HSPF2 8.8 · 1 pairing

  53. 53 KW09XQ19SDOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,600 Btu/h · Cold output 76% · HSPF2 8.8 · 1 pairing

  54. 54 KW36XQ21CDOKinghome
    34,000 Btu/hheating at 47°F 33,600 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 23,800 Btu/h · Cold output 69–72% · HSPF2 8.5 · 4 pairings

  55. 55 KM24UH5OKinghome
    26,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 30,000 Btu/h · Cold output 115% · HSPF2 10.0 · 1 pairing

  56. 56 KM18UH5OKinghome
    21,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 21,800 Btu/h · Cold output 104% · HSPF2 10.0 · 1 pairing

  57. 57 KD48UXOKinghome
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 36,000 Btu/h · Cold output 75% · HSPF2 9.5 · 1 pairing

  58. 58 KM60X6OKinghome
    55,000 Btu/hheating at 47°F 55,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Mini-split · 5°F 32,000 Btu/h · Cold output 56–66% · HSPF2 9.0 · 3 pairings

  59. 59 KW18HQ19CDOKinghome
    17,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,100 Btu/h · Cold output 71% · HSPF2 8.5 · 1 pairing

  60. 60 KW18XQ19SDOKinghome
    17,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,100 Btu/h · Cold output 71% · HSPF2 8.5 · 1 pairing

  61. 61 KUV-48UHOKinghome
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 33,600 Btu/h · Cold output 70% · HSPF2 8.6 · 2 pairings

  62. 62 KW09HQ19SDOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,400 Btu/h · Cold output 74% · HSPF2 8.8 · 1 pairing

  63. 63 KW09HQ19SAOKinghome
    10,000 Btu/hheating at 47°F 9,100 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,400 Btu/h · Cold output 74% · HSPF2 8.6 · 1 pairing

  64. 64 KD60UXOKinghome
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 36,000 Btu/h · Cold output 74–75% · HSPF2 9.5 · 2 pairings

  65. 65 KM42X6OKinghome
    42,000 Btu/hheating at 47°F 42,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Mini-split · 5°F 37,000 Btu/h · Cold output 86–90% · HSPF2 9.0 · 3 pairings

  66. 66 KM48X6OKinghome
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 37,000 Btu/h · Cold output 75–79% · HSPF2 9.0 · 3 pairings

  67. 67 KM36X6OKinghome
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 34,000 Btu/h · Cold output 92–100% · HSPF2 9.0 · 3 pairings

  68. 68 KM30X6OKinghome
    30,000 Btu/hheating at 47°F 28,400 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 26,400 Btu/h · Cold output 87–90% · HSPF2 9.0 · 3 pairings

  69. 69 KM24X6OKinghome
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 21,600 Btu/h · Cold output 90% · HSPF2 9.0 · 3 pairings

  70. 70 KM18X6OKinghome
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 13,700 Btu/h · Cold output 76–77% · HSPF2 9.0 · 3 pairings

  71. 71 KW24HQ19CDOKinghome
    22,400 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 16,800 Btu/h · Cold output 75% · HSPF2 8.5 · 1 pairing

  72. 72 KW12HQ19CDOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 9,100 Btu/h · Cold output 76% · HSPF2 8.5 · 1 pairing

  73. 73 KW12XQ19CDOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 9,100 Btu/h · Cold output 76% · HSPF2 8.5 · 1 pairing

  74. 74 KW12HQ19CAOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,500 Btu/h · Cold output 71% · HSPF2 8.5 · 1 pairing

  75. 75 KM42H5OKinghome
    40,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 32,400 Btu/h · Cold output 81% · HSPF2 9.0 · 3 pairings

  76. 76 KM36H5OKinghome
    36,000 Btu/hheating at 47°F 34,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 30,000 Btu/h · Cold output 83–90% · HSPF2 9.0 · 3 pairings

  77. 77 KM30H5OKinghome
    30,000 Btu/hheating at 47°F 28,400 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 24,800 Btu/h · Cold output 76–89% · HSPF2 9.0 · 3 pairings

  78. 78 KM24H5OKinghome
    24,000 Btu/hheating at 47°F 23,200 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 22,200 Btu/h · Cold output 90–96% · HSPF2 9.0 · 3 pairings

  79. 79 KM18H5OKinghome
    18,000 Btu/hheating at 47°F 17,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 13,800 Btu/h · Cold output 76–78% · HSPF2 9.0 · 3 pairings

  80. 80 KD24UXOKinghome
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 19,000 Btu/h · Cold output 79% · HSPF2 8.3 · 1 pairing

  81. 81 KU18UXOKinghome
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Central · 5°F 18,000 Btu/h · Cold output 100% · HSPF2 9.0 · 1 pairing

  82. 82 KH03TCNHAKinghome
    34,000 Btu/hheating at 47°F 34,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 29,000 Btu/h · Cold output 85% · HSPF2 8.5 · 1 pairing

  83. 83 KH05TCNHAKinghome, Tosot
    57,000 Btu/hheating at 47°F 56,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Central · 5°F 51,000 Btu/h · Cold output 89% · HSPF2 8.3 · 2 pairings

  84. 84 KD30UXOKinghome
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 19,000 Btu/h · Cold output 72–79% · HSPF2 8.3 · 2 pairings

  85. 85 KRH03TCUKinghome
    36,000 Btu/hheating at 47°F 34,400 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 26,000 Btu/h · Cold output 72% · HSPF2 8.8 · 1 pairing

  86. 86 KRH02TCUKinghome
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 24,000 Btu/h · Cold output 100% · HSPF2 8.8 · 1 pairing

  87. 87 KRH04TCUKinghome
    47,000 Btu/hheating at 47°F 47,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 46,000 Btu/h · Cold output 98% · HSPF2 8.5 · 1 pairing

  88. 88 KW12HQ19SAOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,500 Btu/h · Cold output 71% · HSPF2 8.5 · 1 pairing

  89. 89 KW12HQ19SDOKinghome
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,500 Btu/h · Cold output 71% · HSPF2 8.5 · 1 pairing

  90. 90 KD36UXOKinghome
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 17,000 Btu/h · Cold output 64–71% · HSPF2 8.4 · 2 pairings

  91. 91 KU60UXOKinghome
    48,000 Btu/hheating at 47°F 47,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 48,000 Btu/h · Cold output 100% · HSPF2 9.5 · 4 pairings

  92. 92 KU36UXOKinghome
    24,000 Btu/hheating at 47°F 23,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 24,000 Btu/h · Cold output 91–100% · HSPF2 9.3 · 4 pairings

  93. 93 KRH05TCUKinghome
    57,000 Btu/hheating at 47°F 56,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Central · 5°F 45,000 Btu/h · Cold output 79% · HSPF2 8.3 · 1 pairing

  94. 94 KU60UHOKinghome
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 39,000 Btu/h · Cold output 76–81% · HSPF2 9.0 · 2 pairings

  95. 95 KM42UH5OKinghome
    42,000 Btu/hheating at 47°F 42,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Mini-split · 5°F 31,200 Btu/h · Cold output 74% · HSPF2 8.6 · 1 pairing

  96. 96 KM36UH5OKinghome
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 28,200 Btu/h · Cold output 78% · HSPF2 8.6 · 1 pairing

  97. 97 KU36UHOKinghome
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 22,000 Btu/h · Cold output 72–92% · HSPF2 8.8 · 4 pairings

Kinghome heat pumps, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2)
# Model Brands Type Size At 5°FBtu/h · heating At 47°FBtu/h · heating At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed SEER2median pairing HSPF2Btu/Wh · median pairing Compressor Refrigerant Market Pairings
1 KW12XQ29*DO Kinghome Mini-split 12,000 Btu (1-ton)12,200 12,200 12,000 100% 2.00 29.5 10.0 Variable R-32 US CA 1
2 KW12XQ29SDO Kinghome Mini-split 12,000 Btu (1-ton)12,200 12,200 12,000 100% 2.00 29.5 10.0 Variable R-32 US CA 1
3 KW18XQ29SDO Kinghome Mini-split 18,000 Btu (1.5-ton)18,000 18,600 18,000 97% 1.80 27.5 10.0 Variable R-32 US CA 1
4 KW09HQ3D6DO Kinghome Mini-split 9,000 Btu13,000 9,000 9,000 144% 1.91 27.0 11.0 Variable R-410A CA 1
5 KW09XQ25PAO Kinghome Mini-split 9,000 Btu9,500 10,000 9,100 95% 1.83 27.0 10.5 Variable R-32 US CA 1
6 KW09XQ25S1AO Kinghome Mini-split 9,000 Btu9,500 10,000 9,100 95% 1.83 27.0 10.5 Variable R-32 US CA 1
7 KW09XQ25SAO Kinghome Mini-split 9,000 Btu9,500 10,000 9,100 95% 1.83 27.0 10.5 Variable R-32 US CA 1
8 KW24XQ29SDO Kinghome Mini-split 24,000 Btu (2-ton)24,000 24,000 22,000 100% 1.80 27.0 10.0 Variable R-32 US CA 1
9 KW09HQ25SAO Kinghome Mini-split 9,000 Btu9,900 10,000 9,100 99% 1.87 27.0 10.0 Variable R-410A US CA 1
10 KWP09R32C3O Kinghome Mini-split 9,000 Btu12,000 10,500 9,100 114% 1.90 26.0 10.6 Variable R-32 CA 1
11 KW09XQ25PDO Kinghome Mini-split 9,000 Btu9,500 10,500 9,100 90% 1.88 26.0 10.4 Variable R-32 US CA 1
12 KW09XQ25S1DO Kinghome Mini-split 9,000 Btu9,500 10,500 9,100 90% 1.88 26.0 10.4 Variable R-32 US CA 1
13 KW24XQ25PDO Kinghome Mini-split 24,000 Btu (2-ton)19,000 24,000 22,000 79% 1.80 26.0 10.0 Variable R-32 US CA 1
14 KW09HQ25SDO Kinghome Mini-split 9,000 Btu9,100 10,500 9,100 87% 1.86 25.5 10.2 Variable R-410A CA 1
15 KWP12R32C3O Kinghome Mini-split 12,000 Btu (1-ton)13,700 12,000 12,000 114% 1.80 25.5 10.0 Variable R-32 US CA 1
16 KWP24R32C3O Kinghome Mini-split 24,000 Btu (2-ton)20,400 24,000 22,000 85% 1.95 25.0 9.5 Variable R-32 CA 1
17 KW24HQ25SDO Kinghome Mini-split 24,000 Btu (2-ton)17,000 24,000 22,000 71% 1.75 24.5 9.5 Variable R-410A CA 1
18 KWP18R32C3O Kinghome Mini-split 18,000 Btu (1.5-ton)16,500 18,000 18,000 92% 1.80 24.5 9.5 Variable R-32 CA 1
19 KW12XQ25*1DO Kinghome Mini-split 12,000 Btu (1-ton)11,000 12,000 12,000 92% 1.95 24.5 9.5 Variable R-32 US CA 1
20 KW12XQ25PDO Kinghome Mini-split 12,000 Btu (1-ton)11,000 12,000 12,000 92% 1.95 24.5 9.5 Variable R-32 US CA 1
21 KW12XQ25S1DO Kinghome Mini-split 12,000 Btu (1-ton)11,000 12,000 12,000 92% 1.95 24.5 9.5 Variable R-32 US CA 1
22 KW12XQ25PAO Kinghome Mini-split 12,000 Btu (1-ton)9,500 12,000 12,000 79% 1.95 24.5 9.5 Variable R-32 US CA 1
23 KW12XQ25S1AO Kinghome Mini-split 12,000 Btu (1-ton)9,500 12,000 12,000 79% 1.95 24.5 9.5 Variable R-32 US CA 1
24 KW12XQ25SAO Kinghome Mini-split 12,000 Btu (1-ton)9,500 12,000 12,000 79% 1.95 24.5 9.5 Variable R-32 US CA 1
25 KW18XQ25PDO Kinghome Mini-split 18,000 Btu (1.5-ton)14,600 18,000 18,000 81% 1.90 24.5 9.0 Variable R-32 US CA 1
26 KW18XQ25SDO Kinghome Mini-split 18,000 Btu (1.5-ton)14,600 18,000 18,000 81% 1.90 24.5 9.0 Variable R-32 US CA 1
27 KW12HQ25SDO Kinghome Mini-split 12,000 Btu (1-ton)9,000 12,000 12,000 75% 1.85 24.0 9.0 Variable R-410A CA 1
28 KW12HQ25SAO Kinghome Mini-split 12,000 Btu (1-ton)8,800 12,000 12,000 73% 1.85 24.0 9.0 Variable R-410A CA 1
29 KW12HQ3D6DO Kinghome Mini-split 12,000 Btu (1-ton)12,000 12,200 12,000 98% 1.91 24.0 8.5 Variable R-410A CA 1
30 KW09XQ29S1DO Kinghome Mini-split 9,000 Btu9,200 10,500 9,100 81–108% 1.82 23.9 9.5 Variable R-32 US CA 6
31 KW09XQ29SDO Kinghome Mini-split 9,000 Btu9,200 10,500 9,100 81–108% 1.82 23.9 9.5 Variable R-32 US CA 6
32 KW09XQ25SDO Kinghome Mini-split 9,000 Btu9,400 10,500 9,100 72–95% 1.94 23.5 9.5 Variable R-32 US CA 6
33 KW24XQ25SDO Kinghome Mini-split 24,000 Btu (2-ton)18,000 23,000 22,000 78% 1.80 23.5 9.0 Variable R-32 US CA 1
34 KW18HP25SDO Kinghome Mini-split 18,000 Btu (1.5-ton)13,500 18,000 18,000 75% 1.90 23.5 9.0 Variable R-410A CA 1
35 KW24XQ29S1DO Kinghome Mini-split 24,000 Btu (2-ton)21,000 24,000 22,000 71–100% 1.80 23.0 9.3 Variable R-32 US CA 4
36 KW12XQ25SDO Kinghome Mini-split 12,000 Btu (1-ton)10,000 12,000 12,000 83–92% 1.90 23.0 9.3 Variable R-32 US CA 6
37 KUV-36UHO Gree, Kinghome Mini-split 36,000 Btu (3-ton)25,200 36,000 36,000 70% 2.40 23.0 9.0 Variable R-410A CA 3
38 KW12XQ29S1DO Kinghome Mini-split 12,000 Btu (1-ton)10,000 12,000 12,000 83–100% 1.90 23.0 8.8 Variable R-32 US CA 6
39 KW18HQ25SDO Kinghome Mini-split 18,000 Btu (1.5-ton)13,400 18,000 18,000 74% 1.85 23.0 8.5 Variable R-410A CA 1
40 KW18HQ3D6DO Kinghome Mini-split 18,000 Btu (1.5-ton)20,000 18,000 18,000 111% 1.80 22.0 10.0 Variable R-410A CA 1
41 KW18XQ29S1DO Kinghome Mini-split 18,000 Btu (1.5-ton)17,000 18,000 18,000 77–97% 1.80 22.0 9.2 Variable R-32 US CA 7
42 KW18XQ25S1DO Kinghome Mini-split 18,000 Btu (1.5-ton)14,600 18,000 18,000 70–88% 1.90 22.0 9.0 Variable R-32 US CA 4
43 KW30XQ21CDO Kinghome Mini-split 30,000 Btu (2.5-ton)21,000 30,000 30,000 68–77% 1.80 22.0 8.5 Variable R-32 US CA 3
44 KW24HQ3D6DO Kinghome Mini-split 24,000 Btu (2-ton)24,000 24,000 22,000 100% 1.90 21.5 9.5 Variable R-410A CA 1
45 KW24XQ25S1DO Kinghome Mini-split 24,000 Btu (2-ton)18,000 23,000 22,000 78–82% 1.80 21.5 9.0 Variable R-32 US CA 2
46 KM18H5O3 Kinghome Mini-split 18,000 Btu (1.5-ton)13,500 19,000 18,000 71–72% 1.92 21.0 9.0 Variable R-410A CA 3
47 KW36XQ21SDO Kinghome Mini-split 36,000 Btu (3-ton)23,600 34,000 33,600 69% 1.80 21.0 8.5 Variable R-32 US CA 1
48 KW09HQ19CAO Kinghome Mini-split 9,000 Btu7,600 10,000 9,100 76% 1.86 20.5 8.8 Variable R-32 US CA 1
49 KW09HQ19CDO Kinghome Mini-split 9,000 Btu7,600 10,000 9,100 76% 1.94 20.5 8.8 Variable R-32 US CA 1
50 KW09XQ19CAO Kinghome Mini-split 9,000 Btu7,600 10,000 9,100 76% 1.86 20.5 8.8 Variable R-32 US CA 1
51 KW09XQ19CDO Kinghome Mini-split 9,000 Btu7,600 10,000 9,100 76% 1.94 20.5 8.8 Variable R-32 US CA 1
52 KW09XQ19SAO Kinghome Mini-split 9,000 Btu7,600 10,000 9,100 76% 1.86 20.5 8.8 Variable R-32 US CA 1
53 KW09XQ19SDO Kinghome Mini-split 9,000 Btu7,600 10,000 9,100 76% 1.94 20.5 8.8 Variable R-32 US CA 1
54 KW36XQ21CDO Kinghome Mini-split 36,000 Btu (3-ton)23,800 34,000 33,600 69–72% 1.90 20.5 8.5 Variable R-32 US CA 4
55 KM24UH5O Kinghome Mini-split 24,000 Btu (2-ton)30,000 26,000 22,000 115% 1.80 20.0 10.0 Variable R-410A CA 1
56 KM18UH5O Kinghome Mini-split 18,000 Btu (1.5-ton)21,800 21,000 18,000 104% 1.81 20.0 10.0 Variable R-410A CA 1
57 KD48UXO Kinghome Central 48,000 Btu (4-ton)36,000 48,000 48,000 75% 2.18 20.0 9.5 Variable R-32 US CA 1
58 KM60X6O Kinghome Mini-split 54,000 Btu (4.5-ton)32,000 55,000 55,000 56–66% 2.20 20.0 9.0 Variable R-32 US CA 3
59 KW18HQ19CDO Kinghome Mini-split 18,000 Btu (1.5-ton)12,100 17,000 18,000 71% 1.85 20.0 8.5 Variable R-32 US CA 1
60 KW18XQ19SDO Kinghome Mini-split 18,000 Btu (1.5-ton)12,100 17,000 18,000 71% 1.85 20.0 8.5 Variable R-32 US CA 1
61 KUV-48UHO Kinghome Mini-split 48,000 Btu (4-ton)33,600 48,000 48,000 70% 2.05 19.6 8.6 Variable R-410A CA 2
62 KW09HQ19SDO Kinghome Mini-split 9,000 Btu7,400 10,000 9,100 74% 1.81 19.5 8.8 Variable R-410A CA 1
63 KW09HQ19SAO Kinghome Mini-split 9,000 Btu7,400 10,000 9,100 74% 1.81 19.5 8.6 Variable R-410A CA 1
64 KD60UXO Kinghome Central 48,000 Btu (4-ton)36,000 48,000 48,000 74–75% 2.21 19.4 9.5 Variable R-32 US CA 2
65 KM42X6O Kinghome Mini-split 42,000 Btu (3.5-ton)37,000 42,000 42,000 86–90% 1.90 19.0 9.0 Variable R-32 US CA 3
66 KM48X6O Kinghome Mini-split 48,000 Btu (4-ton)37,000 48,000 48,000 75–79% 1.90 19.0 9.0 Variable R-32 US CA 3
67 KM36X6O Kinghome Mini-split 36,000 Btu (3-ton)34,000 36,000 36,000 92–100% 1.90 19.0 9.0 Variable R-32 US CA 3
68 KM30X6O Kinghome Mini-split 30,000 Btu (2.5-ton)26,400 30,000 28,400 87–90% 1.88 19.0 9.0 Variable R-32 US CA 3
69 KM24X6O Kinghome Mini-split 24,000 Btu (2-ton)21,600 24,000 24,000 90% 1.86 19.0 9.0 Variable R-32 US CA 3
70 KM18X6O Kinghome Mini-split 18,000 Btu (1.5-ton)13,700 18,000 18,000 76–77% 1.86 19.0 9.0 Variable R-32 US CA 3
71 KW24HQ19CDO Kinghome Mini-split 24,000 Btu (2-ton)16,800 22,400 24,000 75% 1.81 19.0 8.5 Variable R-32 CA 1
72 KW12HQ19CDO Kinghome Mini-split 12,000 Btu (1-ton)9,100 12,000 12,000 76% 1.80 19.0 8.5 Variable R-32 CA 1
73 KW12XQ19CDO Kinghome Mini-split 12,000 Btu (1-ton)9,100 12,000 12,000 76% 1.80 19.0 8.5 Variable R-32 US CA 1
74 KW12HQ19CAO Kinghome Mini-split 12,000 Btu (1-ton)8,500 12,000 12,000 71% 1.80 19.0 8.5 Variable R-32 CA 1
75 KM42H5O Kinghome Mini-split 36,000 Btu (3-ton)32,400 40,000 36,000 81% 1.84 18.5 9.0 Variable R-410A CA 3
76 KM36H5O Kinghome Mini-split 36,000 Btu (3-ton)30,000 36,000 34,000 83–90% 1.80 18.5 9.0 Variable R-410A CA 3
77 KM30H5O Kinghome Mini-split 30,000 Btu (2.5-ton)24,800 30,000 28,400 76–89% 1.80 18.5 9.0 Variable R-410A CA 3
78 KM24H5O Kinghome Mini-split 24,000 Btu (2-ton)22,200 24,000 23,200 90–96% 1.85 18.5 9.0 Variable R-410A CA 3
79 KM18H5O Kinghome Mini-split 18,000 Btu (1.5-ton)13,800 18,000 17,000 76–78% 1.88 18.5 9.0 Variable R-410A CA 3
80 KD24UXO Kinghome Central 24,000 Btu (2-ton)19,000 24,000 24,000 79% 1.75 18.5 8.3 Variable R-32 US CA 1
81 KU18UXO Kinghome Central 18,000 Btu (1.5-ton)18,000 18,000 18,000 100% 2.00 18.0 9.0 Variable R-32 US CA 1
82 KH03TCNHA Kinghome Central 36,000 Btu (3-ton)29,000 34,000 34,000 85% 1.90 18.0 8.5 Variable R-32 US CA 1
83 KH05TCNHA Kinghome, Tosot Central 54,000 Btu (4.5-ton)51,000 57,000 56,000 89% 2.00 18.0 8.3 Variable R-32 US CA 2
84 KD30UXO Kinghome Central 24,000 Btu (2-ton)19,000 24,000 24,000 72–79% 1.95 17.9 8.3 Variable R-32 US CA 2
85 KRH03TCU Kinghome Central 36,000 Btu (3-ton)26,000 36,000 34,400 72% 1.75 17.8 8.8 Variable R-410A CA 1
86 KRH02TCU Kinghome Central 24,000 Btu (2-ton)24,000 24,000 24,000 100% 1.75 17.8 8.8 Variable R-410A CA 1
87 KRH04TCU Kinghome Central 48,000 Btu (4-ton)46,000 47,000 47,000 98% 1.80 17.8 8.5 Variable R-410A CA 1
88 KW12HQ19SAO Kinghome Mini-split 12,000 Btu (1-ton)8,500 12,000 12,000 71% 1.75 17.5 8.5 Variable R-410A CA 1
89 KW12HQ19SDO Kinghome Mini-split 12,000 Btu (1-ton)8,500 12,000 12,000 71% 1.80 17.5 8.5 Variable R-410A CA 1
90 KD36UXO Kinghome Central 24,000 Btu (2-ton)17,000 24,000 24,000 64–71% 1.93 17.3 8.4 Variable R-32 US CA 2
91 KU60UXO Kinghome Central 48,000 Btu (4-ton)48,000 48,000 47,000 100% 1.93 17.1 9.5 Variable R-32 US CA 4
92 KU36UXO Kinghome Central 24,000 Btu (2-ton)24,000 24,000 23,000 91–100% 1.90 17.0 9.3 Variable R-32 US CA 4
93 KRH05TCU Kinghome Central 54,000 Btu (4.5-ton)45,000 57,000 56,000 79% 1.80 17.0 8.3 Variable R-410A CA 1
94 KU60UHO Kinghome Central 48,000 Btu (4-ton)39,000 48,000 48,000 76–81% 1.80 16.5 9.0 Variable R-410A CA 2
95 KM42UH5O Kinghome Mini-split 42,000 Btu (3.5-ton)31,200 42,000 42,000 74% 1.82 16.0 8.6 Variable R-410A CA 1
96 KM36UH5O Kinghome Mini-split 36,000 Btu (3-ton)28,200 36,000 36,000 78% 1.82 16.0 8.6 Variable R-410A CA 1
97 KU36UHO Kinghome Central 24,000 Btu (2-ton)22,000 24,000 24,000 72–92% 1.80 15.6 8.8 Variable R-410A CA 4

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

97 of 97 units

Other sizes

Every size class, with how many units it holds and its median heat output at 5°F