KM18H5O3
KM18H5O3 is in the certified data.
Its certified full-speed heating output at 5°F is 13,400–13,600 Btu/h3.93–3.99 kW, 71–72% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Kinghome · mini-split heat pump
All 97 certified Kinghome models
KM18H5O3 is in the certified data as of Sep 19, 2026. KM18H5O3 changed its certified heat output at 17°F on AHRI certificate 214655286 from 14,000 Btu/h to 15,200 Btu/h in the certified data between March 2025 and May 2025.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
19,0005.57NR
No 47°F rating for this pairing.
15,2004.45NR at 17°F
13,5003.96NR at 5°F
Btu/hkW, certified
1.92NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 19,000 Btu/h5.57 kW of heat at 47°F, 15,200 Btu/h4.45 kW at 17°F, and 13,500 Btu/h3.96 kW at 5°F, 71% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 500 Btu/h0.15 kW short of the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214655287 · listed by Kinghome · certified Jun 13, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 11 programs in 7 states, provinces, or territories:British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).
All 11 programs by state and province
British Columbia
- CleanBC Energy Savings Program · BC Hydro · FortisBC · municipal utilities
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Manitoba
New Brunswick
Newfoundland and Labrador
Nova Scotia
- Home Energy Assessment: Heat Pump Rebates · Nova Scotia Power
- Moderate Income Rebate · Nova Scotia Power
Ontario
Yukon
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 13,5003.96 kW | −5% | 1.92 | |
| 17°Ffull speed | 15,2004.45 kW | +3% | NR | |
| 47°Fnormal speed | 19,0005.57 kW | +6% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 12.0 in that test. SEER2 21.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.06kW
- Electrical input in the 95°F cooling test
- 1.50kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 13,500 Btu/h3.96 kWNR
- This unit at 5°F median across its pairings
- 13,500 Btu/h3.96 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 34% of them, at number 730 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Among 18,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 845th of 1,110 (tied); HSPF2, 894th of 1,114 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- MUZ-FS18NA: The same 19,000 Btu/h rating at 47°F; 22,400 Btu/h at 5°F (this model: 13,500).
- H18FMHD3XPC: The same 19,000 Btu/h rating at 47°F; 19,300 Btu/h at 5°F (this model: 13,500).
- MUZ-GS18NAHZ: The same 19,000 Btu/h rating at 47°F; 19,000 Btu/h at 5°F (this model: 13,500).
Closest models by heat at 5°F
- WLWHD(18)ND3MOGree · 13,600 Btu/h
- 048-MS-18K2VR-22S-M-OUTDella · 13,500 Btu/h
- 3VIR18HP230V1BOGree · 13,500 Btu/h
- 454-18-O-DADuctlessAire · 13,400 Btu/h
- AO-18U3R25EHisense · 13,400 Btu/h
- AO-18U3R26SSHisense · 13,400 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 13,500 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 320–560 |
| Mild | Typical | 16–26 | 520–840 |
| Mild | Tight, well insulated | 10–18 | 750–1,350 |
| Cold | Drafty, little insulation | 28–52 | 260–480 |
| Cold | Typical | 18–30 | 450–750 |
| Cold | Tight, well insulated | 12–22 | 610–1,130 |
| Very cold | Drafty, little insulation | 32–58 | 230–420 |
| Very cold | Typical | 22–38 | 360–610 |
| Very cold | Tight, well insulated | 16–28 | 480–840 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for KM18H5O3
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 19,000 Btu/h5.57 kWNR | 19,000 Btu/h5.57 kW |
| Heat output at 17°F full speed | 15,200 Btu/h4.45 kWNR | 15,200 Btu/h4.45 kW |
| Heat output at 5°F full speed | 13,500 Btu/h3.96 kWNR | 13,400–13,600 Btu/h3.93–3.99 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 71%NR | |
| COP at 5°F full speed | 1.92NR | 1.88–2.20 |
| HSPF2 Region IV | 9.0NR | 8.1–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 12.0NR | 11.0–12.0 |
| SEER2 cooling season | 21.0NR | 16.0–21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | Canada | Canada |
| Model string as certified | KM18H5O3 | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) KINGHOME 13,500 Btu/h3.96 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | KINGHOME | 13,5003.96 | 19,0005.57 | 18,0005.28 | 71% | 1.92 | Yes | 3 |
Sold as, and units with identical certified values
Variants of the same model number
3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
Other model numbers with identical certified values
3 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- KM18H5O3 changed its certified heat output at 17°F on AHRI certificate 214655286 from 14,000 Btu/h to 15,200 Btu/h in the certified data between March 2025 and May 2025.
- KM18H5O3 was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 13, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read