37MARAQ24AA3
37MARAQ24AA3 is in the certified data.
Its certified full-speed heating output at 5°F is 18,000–19,600 Btu/h5.28–5.74 kW, 72–78% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Bryant, Carrier + 3 more · mini-split heat pump
37MARAQ24AA3 is in the certified data as of Sep 19, 2026. 37MARAQ24AA3 changed its certified heat output at 17°F on 5 pairings from 18,800 Btu/h to 22,400 Btu/h in the certified data between August 2025 and September 2026.
- 24,000 Btu (2-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
24,4007.15NR
No 47°F rating for this pairing.
20,0005.86NR at 17°F
18,6005.45NR at 5°F
Btu/hkW, certified
2.27NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 24,400 Btu/h7.15 kW of heat at 47°F, 20,000 Btu/h5.86 kW at 17°F, and 18,600 Btu/h5.45 kW at 5°F, 76% of its 47°F rating. It delivers 24,000 Btu/h7.03 kW of cooling at 95°F. At 5°F that is 400 Btu/h0.12 kW short of the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 14,500 Btu/h4.25 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215323834 · listed by Carrier · certified Mar 4, 2025 · 5 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 18,6005.45 kW | −2% | 2.27 | |
| 17°Ffull speed | 20,0005.86 kW | 0% | NR | |
| 47°Fnormal speed | 24,4007.15 kW | −2% | NR | |
| 95°Fcooling, full load | 24,0007.03 kW | — | NR |
EER2 12.2 in that test. SEER2 21.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.40kW
- Electrical input in the 95°F cooling test
- 1.97kW
- Seasonal average heating COP
- 3.25
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton mini-split models
- This pairing at 5°F
- 18,600 Btu/h5.45 kWNR
- This unit at 5°F median across its pairings
- 18,600 Btu/h5.45 kW
- Median of 2-ton mini-split models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 917
This unit is above 37% of them, at number 579 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.
Closest models by heat at 5°F
- YN030GMFI22M3EPioneer · 18,800 Btu/h
- DIY-MULTI4-27HP230D-OMRCOOL · 18,700 Btu/h
- 048-C-TP-23K2V-23S-OUTDella · 18,600 Btu/h
- 37MTRAQ27DA3Bryant, Carrier + 3 more · 18,600 Btu/h
- H24SUH23XGCTCL · 18,600 Btu/h
- LEO24K30S25V220H1LEO Air · 18,600 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 37MARAQ24AA3
27 pairings · 27 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 24,400 Btu/h7.15 kWNR | 24,400–25,000 Btu/h7.15–7.33 kW |
| Heat output at 17°F full speed | 20,000 Btu/h5.86 kWNR | 17,600–22,400 Btu/h5.16–6.56 kW |
| Heat output at 5°F full speed | 18,600 Btu/h5.45 kWNR | 18,000–19,600 Btu/h5.28–5.74 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 76%NR | |
| COP at 5°F full speed | 2.27NR | 2.20–2.54 |
| HSPF2 Region IV | 11.1NR | 9.0–11.7 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 24,000 Btu/h7.03 kWNR | 24,000 Btu/h7.03 kW |
| EER2 at 95°F | 12.2NR | 11.7–14.0 |
| SEER2 cooling season | 21.2NR | 19.0–23.1 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | 45MCFAQ24XA3 | 7 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 37MARAQ24AA3 | |
Pairings, by indoor-unit class
7 indoor units · 27 certified pairings
One row per indoor unit certified with this outdoor unit.
Air handler · 1 indoor unit
-
45MBAAQ24XB3 (the pairing on screen) brand not stated 18,000 Btu/h5.28 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 45MBAAQ24XB3 (the pairing on screen) | — | 18,0005.28 | 25,0007.33 | 24,0007.03 | 72% | 2.20 | Yes | 5 |
Ductless indoor · 6 indoor units
-
45MBCAQ24XA3 (the pairing on screen) BRYANT 18,500 Btu/h5.42 kWat 5°F, full speed
-
45MBDAQ24XH3 (the pairing on screen) BRYANT 19,000 Btu/h5.57 kWat 5°F, full speed
-
45MCFAQ24XA3 (the pairing on screen) BRYANT 18,600 Btu/h5.45 kWat 5°F, full speed
-
D5MAHAQ24XA3 (the pairing on screen) BRYANT 19,600 Btu/h5.74 kWat 5°F, full speed
-
45MAHAQ24XA3 (the pairing on screen) CARRIER 19,600 Btu/h5.74 kWat 5°F, full speed
-
615AHAQ24XA3 (the pairing on screen) BRYANT 19,600 Btu/h5.74 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 45MBCAQ24XA3 (the pairing on screen) | BRYANT | 18,5005.42 | 25,0007.33 | 24,0007.03 | 74% | 2.30 | Yes | 5 |
| 45MBDAQ24XH3 (the pairing on screen) | BRYANT | 19,0005.57 | 25,0007.33 | 24,0007.03 | 76% | 2.30 | Yes | 5 |
| 45MCFAQ24XA3 (the pairing on screen) | BRYANT | 18,6005.45 | 24,4007.15 | 24,0007.03 | 76% | 2.27 | Yes | 5 |
| D5MAHAQ24XA3 (the pairing on screen) | BRYANT | 19,6005.74 | 25,0007.33 | 24,0007.03 | 78% | 2.54 | Yes | 5 |
| 45MAHAQ24XA3 (the pairing on screen) | CARRIER | 19,6005.74 | 25,0007.33 | 24,0007.03 | 78% | 2.54 | Yes | 1 |
| 615AHAQ24XA3 (the pairing on screen) | BRYANT | 19,6005.74 | 25,0007.33 | 24,0007.03 | 78% | 2.54 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
- Are Bryant and Carrier heat pumps the same?127 shared model numbers
- Are Bryant and Midea heat pumps the same?108 shared model numbers
- Are Bryant and WeatherMaker heat pumps the same?108 shared model numbers
- Are Bryant and Payne heat pumps the same?107 shared model numbers
Model number as listed
- 37MARAQ24AA3 27 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- 37MARAQ24AA3 changed its certified heat output at 17°F on 5 pairings from 18,800 Btu/h to 22,400 Btu/h in the certified data between August 2025 and September 2026.
- 37MARAQ24AA3 was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 4, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read