YN030GMFI22M3E
YN030GMFI22M3E is in the certified data.
Its certified full-speed heating output at 5°F is 18,700–19,000 Btu/h5.48–5.57 kW, 67–68% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Pioneer · mini-split heat pump
YN030GMFI22M3E is in the certified data as of Sep 19, 2026.
- 24,000 Btu (2-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
28,0008.21NR
No 47°F rating for this pairing.
21,0006.15NR at 17°F
18,8005.51NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 28,000 Btu/h8.21 kW of heat at 47°F, 21,000 Btu/h6.15 kW at 17°F, and 18,800 Btu/h5.51 kW at 5°F, 67% of its 47°F rating. It delivers 27,400 Btu/h8.03 kW of cooling at 95°F. At 5°F that is 200 Btu/h0.06 kW short of the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 17,900 Btu/h5.25 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 208121966 · listed by Pioneer · certified Apr 17, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 18,8005.51 kW | −1% | 2.00 | |
| 17°Ffull speed | 21,0006.15 kW | +5% | NR | |
| 47°Fnormal speed | 28,0008.21 kW | +12% | NR | |
| 95°Fcooling, full load | 27,4008.03 kW | — | NR |
EER2 11.95 in that test. SEER2 22.25 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.75kW
- Electrical input in the 95°F cooling test
- 2.29kW
- Seasonal average heating COP
- 2.70
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton mini-split models
- This pairing at 5°F
- 18,800 Btu/h5.51 kWNR
- This unit at 5°F median across its pairings
- 18,800 Btu/h5.51 kW
- Median of 2-ton mini-split models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 917
This unit is above 41% of them, at number 540 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.
Closest models by heat at 5°F
- MULTI4-27HP230C-OMRCOOL · 18,900 Btu/h
- YN030GLSI24M3GPioneer · 18,900 Btu/h
- VMH24A5-VA1B3NB(O)Vino · 18,800 Btu/h
- DIY-MULTI4-27HP230D-OMRCOOL · 18,700 Btu/h
- 048-C-TP-23K2V-23S-OUTDella · 18,600 Btu/h
- 37MARAQ24AA3Bryant, Carrier + 3 more · 18,600 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YN030GMFI22M3E
4 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 28,000 Btu/h8.21 kWNR | 28,000 Btu/h8.21 kW |
| Heat output at 17°F full speed | 21,000 Btu/h6.15 kWNR | 20,000–22,000 Btu/h5.86–6.45 kW |
| Heat output at 5°F full speed | 18,800 Btu/h5.51 kWNR | 18,700–19,000 Btu/h5.48–5.57 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 67%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 9.2NR | 9.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 27,400 Btu/h8.03 kWNR | 27,000–28,000 Btu/h7.91–8.21 kW |
| EER2 at 95°F | 11.95NR | 11.7–12.2 |
| SEER2 cooling season | 22.25NR | 21.0–23.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | YN030GMFI22M3E | |
Pairings, by indoor-unit class
4 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) PIONEER 18,900 Btu/h5.54 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | PIONEER | 18,9005.54 | 28,0008.21 | 27,2007.97 | 68% | 2.00 | NC | 4 |
Sold as, and units with identical certified values
Variants of the same model number
20 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 3KARDA27MZ3Karda · PerfectAire
- 3PAMSH27-MZO3PerfectAire
- A3MO21-27N1-M1AI Air Conditioning
- AM3OJ-27HFN1ApooDr
- BMM27CBlueridge
- DRA3U28M1BDuraSTAR
- EMH-3O27BBEco AC
- KWSMO-27R410AIHHKANIONco
- KWSMO-30R410AIHMVKANIONco
- LEA27MZ-3P-25SK-ONovair
- LMHB27DOLBG Products
- M3OJ-27HFN1-M-COMidea
- MMRSHC27AS3Classic
- MMRSHT27AS3TGM
- MOBMH270CNG Trade
- SAK-27-22MUZ/220(OUT)*Star Air Kontrol
- SHC3Z27VC2AGSlimAir
- WMMA-27HFMOWells
- Z3SOV-27HDM-USZero
19 of 20 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 17, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read