Heat Pump List

Tools

38MTRAQ48EA3

38MTRAQ48EA3 is in the certified data.

Its certified full-speed heating output at 5°F is 34,000 Btu/h, 71% of its 47°F rating (tests at different compressor speeds) across its certified pairings.

Bryant, Carrier + 3 more · mini-split heat pump

All 205 certified Bryant models · All 187 certified Carrier models · All 359 certified Midea models · All 107 certified Payne models · All 123 certified WeatherMaker models

38MTRAQ48EA3 is in the certified data as of Sep 19, 2026.

Certified heating and cooling

Heating at 47°F

48,000

32,000 at 17°F

34,000 at 5°F

Btu/h, certified

1.80 COP at 5°F

Cooling at 95°F

48,000

Btu/h, certified

EER2 10.0 at 95°F

SEER2 18.7

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for 38MTRAQ48EA3, by outdoor temperature Heating: 34,000 Btu/h at 5°F, 32,000 Btu/h at 17°F, 48,000 Btu/h at 47°F. Cooling: 48,000 Btu/h at 95°F. The bars start at zero. Median of 4-ton mini-split models: 42,000 Btu/h at 5°F, 38,000 Btu/h at 17°F, 49,000 Btu/h at 47°F, 48,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 50,000 Btu/h 34,000 5°F 32,000 17°F 48,000 47°F 48,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 48,000 Btu/h of heat at 47°F, 32,000 Btu/h at 17°F, and 34,000 Btu/h at 5°F, 71% of its 47°F rating. It delivers 48,000 Btu/h of cooling at 95°F. At 5°F that is 8,000 Btu/h short of the example heating load of 42,000 Btu/h; at 95°F it is 27,000 Btu/h above the example cooling load of 21,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,750 sq ft where winters reach 5°F: heating runs from 42,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 21,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 213363514 · listed by Carrier · certified Mar 4, 2025 · 5 pairings on 5 certificates share these values

Rebates where you live

Meets the recorded equipment thresholds of 41 programs in 30 states, provinces, or territories:Alabama (1), Arizona (1), California (2), Connecticut (1), Delaware (1), Idaho (2), Illinois (1), Kentucky (1), Maryland (3), Massachusetts (1), Michigan (2), Minnesota (2), Mississippi (2), New Hampshire (1), New Jersey (3), New York (4), Oregon (2), Rhode Island (1), Tennessee (1), Utah (1), Vermont (3), Washington (1), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 41 programs by state and province

Alabama

Arizona

California

Connecticut

Delaware

Idaho

Illinois

Kentucky

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

New Hampshire

New Jersey

New York

Oregon

Rhode Island

Tennessee

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 34,0009.96 kW −19% 1.80
17°Ffull speed 32,0009.38 kW −16% NR
47°Fnormal speed 48,00014.07 kW −2% NR
95°Fcooling, full load 48,00014.07 kW — NR

EER2 10.0 in that test. SEER2 18.7 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
5.54kW
Electrical input in the 95°F cooling test
4.80kW
Seasonal average heating COP
2.58

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 48,000 Btu heat pumps

4-ton mini-split models

This pairing at 5°F
34,000 Btu/h
This unit at 5°F median across its pairings
34,000 Btu/h
Median of 4-ton mini-split models at 5°F
42,000 Btu/h
Models in this group
321

This unit is above 13% of them, at number 279 of 321 by heat at 5°F. The middle half of the group runs 37,000 to 47,500 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 48,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 245th of 321 (tied); HSPF2, 307th of 321 (tied). Models without that figure are left out.

Similar ratings at 47°F

These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • AUW-48U3TH1: The same 48,000 Btu/h rating at 47°F; 48,000 Btu/h at 5°F (this model: 34,000).
  • TMFX48HEI2NAS0U25: The same 48,000 Btu/h rating at 47°F; 42,000 Btu/h at 5°F (this model: 34,000).
  • H48FMHD6XPC: The same 48,000 Btu/h rating at 47°F; 41,500 Btu/h at 5°F (this model: 34,000).

Closest models by heat at 5°F

Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 34,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42810–1,420
MildTypical16–261,310–2,130
MildTight, well insulated10–181,890–3,400
ColdDrafty, little insulation28–52650–1,210
ColdTypical18–301,130–1,890
ColdTight, well insulated12–221,550–2,830
Very coldDrafty, little insulation32–58590–1,060
Very coldTypical22–38890–1,550
Very coldTight, well insulated16–281,210–2,130

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for 38MTRAQ48EA3

5 pairings · 5 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for 38MTRAQ48EA3
This pairingAll pairings
Heating
Heat output at 47°F normal speed 48,000 Btu/h 48,000 Btu/h
Heat output at 17°F full speed 32,000 Btu/h 32,000 Btu/h
Heat output at 5°F full speed 34,000 Btu/h 34,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 71%
COP at 5°F full speed 1.80 1.80
HSPF2 Region IV 8.8 8.8
Cooling
Cooling capacity at 95°F full-load test 48,000 Btu/h 48,000 Btu/h
EER2 at 95°F 10.0 10.0
SEER2 cooling season 18.7 18.7
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit None listed None
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified 38MTRAQ48EA3

Pairings, by indoor-unit class

5 certified pairings

One row per indoor unit certified with this outdoor unit.

Ductless indoor

  1. None listed (the pairing on screen) BRYANT 34,000 Btu/hat 5°F, full speed

    5 pairings · 47°F 48,000 Btu/h · 95°F cooling 48,000 Btu/h · Cold output 71% · COP 1.80

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
None listed (the pairing on screen) BRYANT 34,000 48,000 48,000 71% 1.80 Yes 5

The share is heat output at 5°F divided by the 47°F rating.

Sold as, and units with identical certified values

History and definitions

Other 38M series models by nominal cooling size: 38MPRBQ09AA3 (9,000 Btu), 38MPRBQ12AA3 (12,000 Btu), 38MHRCQ18AA3 (18,000 Btu), 38MTRAQ18BA3 (18,000 Btu), 38MTRAQ27CA3 (24,000 Btu), 38MARBQ30AA3 (30,000 Btu), 38MARBQ30AA311 (30,000 Btu), 38MURAQ30AB3 (30,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Mar 4, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “38MTRAQ48EA3 — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/38mtraq48ea3