48NR*B36***30*
Carrier · central heat pump
48NR*B36***30* is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
34,40010.08NR
No 47°F rating for this pairing.
19,6005.74NR at 17°F
14,1004.13NR at 5°F
Btu/hkW, certified
1.70NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 34,400 Btu/h10.08 kW of heat at 47°F, 19,600 Btu/h5.74 kW at 17°F, and 14,100 Btu/h4.13 kW at 5°F, 41% of its 47°F rating. It delivers 35,200 Btu/h10.32 kW of cooling at 95°F. At 5°F that is 12,400 Btu/h3.63 kW short of the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 22,200 Btu/h6.51 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217154370 · listed by Carrier · certified Apr 9, 2025 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 14,1004.13 kW | −47% | 1.70 | |
| 17°Fone compressor speed | 19,6005.74 kW | −25% | NR | |
| 47°Fone compressor speed | 34,40010.08 kW | −2% | NR | |
| 95°Fcooling, full load | 35,20010.32 kW | — | NR |
EER2 11.5 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.43kW
- Electrical input in the 95°F cooling test
- 3.06kW
- Seasonal average heating COP
- 2.11
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 14,100 Btu/h4.13 kWNR
- This unit at 5°F median across its pairings
- 14,100 Btu/h4.13 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 2% of them, at number 440 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- LRP15HPK36VPLennox · 15,200 Btu/h
- EL19KPV-036-230ALennox · 15,100 Btu/h
- DHH0361********A*Daikin · 15,000 Btu/h
- LDT036H5E*1PAllied Commercial and Lennox · 14,000 Btu/h
- RHPBYC036AJTFriedrich, Rheem + 4 more · 13,900 Btu/h
- RHPXYC036AJTFriedrich, Mainline + 5 more · 13,800 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 48NR*B36***30*
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 34,400 Btu/h10.08 kWNR | 34,400 Btu/h10.08 kW |
| Heat output at 17°F full speed | 19,600 Btu/h5.74 kWNR | 19,600 Btu/h5.74 kW |
| Heat output at 5°F full speed | 14,100 Btu/h4.13 kWNR | 14,100 Btu/h4.13 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 41%NR | |
| COP at 5°F full speed | 1.70NR | 1.70 |
| HSPF2 Region IV | 7.2NR | 7.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 35,200 Btu/h10.32 kWNR | 35,200 Btu/h10.32 kW |
| EER2 at 95°F | 11.5NR | 11.5 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Two-stage | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 48NR*B36***30* | |
Pairings, by indoor-unit class
1 certified pairing
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated 14,100 Btu/h4.13 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | 14,1004.13 | 34,40010.08 | 35,20010.32 | 41% | 1.70 | NC | 1 |
Sold as, and units with identical certified values
Variants of the same model number
5 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 50NR-B36---30Carrier
- 605ENXB36000AABryant
- 675ENWB36****A*Bryant
- PHB536000K000BAirquest · Arcoaire · Comfortmaker · Day & Night · Heil · ICP Commercial · Keeprite · Kenmore · Maratherm · MSH Legacy · Tempstar
4 of 5 shown.
Other model numbers with identical certified values
4 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 50NR-B36---30identical certified values
- 605ENXB36000AAidentical certified values
- 675ENWB36****A*identical certified values
3 of 4 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- 48NR*B36***30* first appeared in the certified data between March 2025 and May 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 9, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read