4A6L9048A1
4A6L9048A1 is in the certified data.
Its certified ratings are 8.7–9.0 HSPF2 and 19.0 SEER2, depending on the pairing.
American Standard · central heat pump
4A6L9048A1 is in the certified data as of Sep 19, 2026.
- 48,000 Btu (4-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
43,50012.75NR
No 47°F rating for this pairing.
31,8009.32NR at 17°F
——NRNR at 5°F
Btu/hkW, certified
—NRNR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 43,500 Btu/h12.75 kW of heat at 47°F and 31,800 Btu/h9.32 kW at 17°F. It delivers 49,000 Btu/h14.36 kW of cooling at 95°F. At 95°F that is 31,000 Btu/h9.09 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 210691993 · listed by American Standard · certified May 3, 2023 · 2 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | NR— kW | NR | NR | |
| 17°Ffull speed | 31,8009.32 kW | −9% | NR | |
| 47°Fnormal speed | 43,50012.75 kW | −9% | NR | |
| 95°Fcooling, full load | 49,00014.36 kW | — | NR |
EER2 11.7 in that test. SEER2 19.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- NRkW
- Electrical input in the 95°F cooling test
- 4.19kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- — Btu/h— kWNRNR
- This unit at 5°F median across its pairings
- NR
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 4A6L9048A1
8 pairings · 8 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 43,500 Btu/h12.75 kWNR | 42,000–43,500 Btu/h12.31–12.75 kW |
| Heat output at 17°F full speed | 31,800 Btu/h9.32 kWNR | 30,600–31,800 Btu/h8.97–9.32 kW |
| Heat output at 5°F full speed | — Btu/h— kWNRNR | NR |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | —%NRNR | NR |
| COP at 5°F full speed | —NRNR | — |
| HSPF2 Region IV | 9.0NR | 8.7–9.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 49,000 Btu/h14.36 kWNR | 47,000–49,000 Btu/h13.77–14.36 kW |
| EER2 at 95°F | 11.7NR | 11.7–12.0 |
| SEER2 cooling season | 19.0NR | 19.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | 4PX*DU60BS3 | 5 indoor units |
| Furnace | S8V2D120M5PCA | 3 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 4A6L9048A1 | |
Pairings, by indoor-unit class
5 indoor units · 8 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 5 indoor units
-
4PX*DU60BS3 (the pairing on screen) brand not stated NRat 5°F, full speed
-
4TXCD010DS3 (the pairing on screen) brand not stated NRat 5°F, full speed
-
4PX*DD60BS3 (the pairing on screen) brand not stated NRat 5°F, full speed
-
4PX*DU48BS3 (the pairing on screen) brand not stated NRat 5°F, full speed
-
4TXCD008DS3 (the pairing on screen) brand not stated NRat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 4PX*DU60BS3 (the pairing on screen) | — | NR | 42,75012.53 | 49,00014.36 | NR | — | NC | 3 |
| 4TXCD010DS3 (the pairing on screen) | — | NR | 43,50012.75 | 49,00014.36 | NR | — | NC | 2 |
| 4PX*DD60BS3 (the pairing on screen) | — | NR | NR | 48,00014.07 | NR | — | NC | 1 |
| 4PX*DU48BS3 (the pairing on screen) | — | NR | NR | 48,00014.07 | NR | — | NC | 1 |
| 4TXCD008DS3 (the pairing on screen) | — | NR | NR | 48,00014.07 | NR | — | NC | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- 4A6L9048A1 8 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- May 3, 2023
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read