5TWX5018A1
Trane · central heat pump
All 104 certified Trane models
5TWX5018A1 is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Central
- Single stage
- US and Canada
Certified heating and cooling
Heating at 47°F
18,3005.36NR
No 47°F rating for this pairing.
11,8003.46NR at 17°F
8,9002.61NR at 5°F
Btu/hkW, certified
2.10NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 18,300 Btu/h5.36 kW of heat at 47°F, 11,800 Btu/h3.46 kW at 17°F, and 8,900 Btu/h2.61 kW at 5°F, 49% of its 47°F rating. It delivers 19,200 Btu/h5.63 kW of cooling at 95°F. At 5°F that is 2,100 Btu/h0.62 kW short of the example heating load of 11,000 Btu/h3.22 kW; at 95°F it is 13,700 Btu/h4.02 kW above the example cooling load of 5,500 Btu/h1.61 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 450 sq ft where winters reach 5°F: heating runs from 11,000 Btu/h3.22 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,500 Btu/h1.61 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215863960 · listed by Trane · certified Jun 3, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 8,9002.61 kW | −21% | 2.10 | |
| 17°Fone compressor speed | 11,8003.46 kW | −6% | NR | |
| 47°Fone compressor speed | 18,3005.36 kW | +2% | NR | |
| 95°Fcooling, full load | 19,2005.63 kW | — | NR |
EER2 12.0 in that test. SEER2 15.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.24kW
- Electrical input in the 95°F cooling test
- 1.60kW
- Seasonal average heating COP
- 2.34
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton central models
- This pairing at 5°F
- 8,900 Btu/h2.61 kWNR
- This unit at 5°F median across its pairings
- 8,900 Btu/h2.61 kW
- Median of 1.5-ton central models at 5°F
- 11,200 Btu/h3.28 kW
- Models in this group
- 243
This unit is above 30% of them, at number 171 of 243 by heat at 5°F. The middle half of the group runs 8,600 to 18,000 Btu/h.
Among 18,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 189th of 243; HSPF2, 190th of 254. Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- ML15KSPV-018-230A: 18,500 Btu/h at 47°F (this model: 18,300); 13,900 Btu/h at 5°F (this model: 8,900).
- AHU18HPV1BO: 18,000 Btu/h at 47°F (this model: 18,300); 20,400 Btu/h at 5°F (this model: 8,900).
- AHU3G-18HFN-B: 18,000 Btu/h at 47°F (this model: 18,300); 18,600 Btu/h at 5°F (this model: 8,900).
Closest models by heat at 5°F
- MLP15AZ18AJ2NMainline · 9,200 Btu/h
- SP15AZ18AJ2NRussell and Sure · 9,200 Btu/h
- A5HP5018A1Ameristar and RunTru · 9,000 Btu/h
- N5HP5018A1American Standard and Trane · 8,900 Btu/h
- YH518E2S11York · 8,900 Btu/h
- YH618E2S11York · 8,900 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 8,900 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 210–370 |
| Mild | Typical | 16–26 | 340–560 |
| Mild | Tight, well insulated | 10–18 | 490–890 |
| Cold | Drafty, little insulation | 28–52 | 170–320 |
| Cold | Typical | 18–30 | 300–490 |
| Cold | Tight, well insulated | 12–22 | 400–740 |
| Very cold | Drafty, little insulation | 32–58 | 150–280 |
| Very cold | Typical | 22–38 | 230–400 |
| Very cold | Tight, well insulated | 16–28 | 320–560 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for 5TWX5018A1
6 pairings · 6 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 18,300 Btu/h5.36 kWNR | 17,200–18,600 Btu/h5.04–5.45 kW |
| Heat output at 17°F full speed | 11,800 Btu/h3.46 kWNR | 11,200–12,200 Btu/h3.28–3.58 kW |
| Heat output at 5°F full speed | 8,900 Btu/h2.61 kWNR | 8,600–9,300 Btu/h2.52–2.73 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 49%NR | |
| COP at 5°F full speed | 2.10NR | 1.90–2.10 |
| HSPF2 Region IV | 8.0NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 19,200 Btu/h5.63 kWNR | 17,800–19,200 Btu/h5.22–5.63 kW |
| EER2 at 95°F | 12.0NR | 11.7–12.0 |
| SEER2 cooling season | 15.5NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Single stage | |
| Indoor unit | 5TEMCB02AV21+TDR+TSTAT | 6 indoor units |
| Furnace | No furnace | 1 furnace |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 5TWX5018A1 | |
Across 6 certified pairings with 6 indoor models: heat at 5°F 8,600 Btu/h with 5TXCB004AS3+TSTAT to 9,300 Btu/h with 5TEM6B02AV21+TDR+TSTAT; HSPF2 7.8 with 5TEM4B02AC21+TDR+TSTAT to 8.1 with 5TEM6B03AV21+TDR+TSTAT; SEER2 15.2 with 5TEM4B02AC21+TDR+TSTAT to 16.0 with 5TEMCB03AV31+TDR+TSTAT. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.
Pairings, by indoor-unit class
6 indoor units · 6 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 1 indoor unit
-
5TXCB004AS3+TSTAT (the pairing on screen) brand not stated 8,600 Btu/h2.52 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5TXCB004AS3+TSTAT (the pairing on screen) | — | 8,6002.52 | 17,2005.04 | 17,8005.22 | 50% | 1.90 | NC | 1 |
Air handler · 5 indoor units
-
5TEM4B02AC21+TDR+TSTAT (the pairing on screen) brand not stated 9,000 Btu/h2.64 kWat 5°F, full speed
-
5TEM6B02AV21+TDR+TSTAT (the pairing on screen) brand not stated 9,300 Btu/h2.73 kWat 5°F, full speed
-
5TEM6B03AV21+TDR+TSTAT (the pairing on screen) brand not stated 9,200 Btu/h2.70 kWat 5°F, full speed
-
5TEMCB02AV21+TDR+TSTAT (the pairing on screen) brand not stated 8,900 Btu/h2.61 kWat 5°F, full speed
-
5TEMCB03AV31+TDR+TSTAT (the pairing on screen) brand not stated 8,900 Btu/h2.61 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5TEM4B02AC21+TDR+TSTAT (the pairing on screen) | — | 9,0002.64 | 18,5005.42 | 19,2005.63 | 49% | 2.00 | NC | 1 |
| 5TEM6B02AV21+TDR+TSTAT (the pairing on screen) | — | 9,3002.73 | 18,6005.45 | 19,0005.57 | 50% | 2.00 | NC | 1 |
| 5TEM6B03AV21+TDR+TSTAT (the pairing on screen) | — | 9,2002.70 | 18,6005.45 | 18,8005.51 | 49% | 2.00 | NC | 1 |
| 5TEMCB02AV21+TDR+TSTAT (the pairing on screen) | — | 8,9002.61 | 18,3005.36 | 19,2005.63 | 49% | 2.10 | NC | 1 |
| 5TEMCB03AV31+TDR+TSTAT (the pairing on screen) | — | 8,9002.61 | 18,3005.36 | 19,2005.63 | 49% | 2.10 | NC | 1 |
Sold as, and units with identical certified values
Variants of the same model number
3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
Other 15 Single-Stage Heat Pump with WeatherGuard Top models by nominal cooling size: 5TWX5024A1 (24,000 Btu), 5TWX5036A1 (36,000 Btu), 5TWX5042A1 (42,000 Btu), 5TWX5048A1 (42,000 Btu), 5TWX5060A1 (54,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 3, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read