7HP14F36P-**A
7HP14F36P-**A is in the certified data.
Its certified full-speed heating output at 5°F is 15,700–16,800 Btu/h4.60–4.92 kW, 46–53% of its 47°F rating, depending on the pairing.
Allied, Breeze33 + 2 more · central heat pump
7HP14F36P-**A is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Central
- Single stage
- US and Canada
Certified heating and cooling
Heating at 47°F
34,60010.14NR
No 47°F rating for this pairing.
20,2005.92NR at 17°F
16,6004.86NR at 5°F
Btu/hkW, certified
1.98NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 34,600 Btu/h10.14 kW of heat at 47°F, 20,200 Btu/h5.92 kW at 17°F, and 16,600 Btu/h4.86 kW at 5°F, 48% of its 47°F rating. It delivers 36,000 Btu/h10.55 kW of cooling at 95°F. At 5°F that is 9,900 Btu/h2.90 kW short of the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 23,000 Btu/h6.74 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215735969 · listed by ALLIED · certified Jul 3, 2025 · 8 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 16,6004.86 kW | −37% | 1.98 | |
| 17°Fone compressor speed | 20,2005.92 kW | −23% | NR | |
| 47°Fone compressor speed | 34,60010.14 kW | −2% | NR | |
| 95°Fcooling, full load | 36,00010.55 kW | — | NR |
EER2 13.2 in that test. SEER2 15.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.46kW
- Electrical input in the 95°F cooling test
- 2.73kW
- Seasonal average heating COP
- 2.29
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 16,600 Btu/h4.86 kWNR
- This unit at 5°F median across its pairings
- 16,600 Btu/h4.86 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 6% of them, at number 426 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- GSZC703610AGoodman · 17,000 Btu/h
- MOVA-36HN10-M152LMidea · 16,900 Btu/h
- ML14KP1-036-230ALennox · 16,800 Btu/h
- BH714S36P-**AAC Pro, Blueridge + 1 more · 16,600 Btu/h
- EL16KP1-036-230ALennox · 16,600 Btu/h
- HSA1436S1-**ACentury and Comfort-Aire · 16,600 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 7HP14F36P-**A
135 pairings · 135 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 34,600 Btu/h10.14 kWNR | 31,400–35,600 Btu/h9.20–10.43 kW |
| Heat output at 17°F full speed | 20,200 Btu/h5.92 kWNR | 20,000–21,200 Btu/h5.86–6.21 kW |
| Heat output at 5°F full speed | 16,600 Btu/h4.86 kWNR | 15,700–16,800 Btu/h4.60–4.92 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 48%NR | |
| COP at 5°F full speed | 1.98NR | 1.90–2.06 |
| HSPF2 Region IV | 7.8NR | 7.8–8.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 36,000 Btu/h10.55 kWNR | 35,400–36,000 Btu/h10.37–10.55 kW |
| EER2 at 95°F | 13.2NR | 12.5–13.4 |
| SEER2 cooling season | 15.5NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Single stage | |
| Indoor unit | 7EH42CX-**+TDR | 9 indoor units |
| Furnace | 80G1UH110CE20* | 21 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | US and Canada |
| Model string as certified | 7HP14F36P-**A | |
Pairings, by indoor-unit class
9 indoor units · 135 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 3 indoor units
-
7EH42CX-**+TDR (the pairing on screen) brand not stated 16,600 Btu/h4.86 kWat 5°F, full speed
-
7E[C,U]48CX-**+TDR (the pairing on screen) brand not stated 16,600 Btu/h4.86 kWat 5°F, full speed
-
7EH42BX-**+TDR (the pairing on screen) brand not stated 16,600 Btu/h4.86 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 7EH42CX-**+TDR (the pairing on screen) | — | 16,6004.86 | 34,60010.14 | 36,00010.55 | 48% | 1.98 | NC | 48 |
| 7E[C,U]48CX-**+TDR (the pairing on screen) | — | 16,6004.86 | 34,80010.20 | 36,00010.55 | 48% | 2.00 | NC | 36 |
| 7EH42BX-**+TDR (the pairing on screen) | — | 16,6004.86 | 34,80010.20 | 36,00010.55 | 48% | 1.98 | NC | 28 |
Air handler · 6 indoor units
-
7AH1AE36PX-** (the pairing on screen) brand not stated 15,900 Btu/h4.66 kWat 5°F, full speed
-
7AH1AV36PX-** (the pairing on screen) brand not stated 15,700 Btu/h4.60 kWat 5°F, full speed
-
7AH2AE36PX-** (the pairing on screen) brand not stated 16,600 Btu/h4.86 kWat 5°F, full speed
-
7AH2AE42PX*** (the pairing on screen) brand not stated 16,300 Btu/h4.78 kWat 5°F, full speed
-
7AH2AV42PXC*** (the pairing on screen) brand not stated 16,300 Btu/h4.78 kWat 5°F, full speed
-
7AH1RE42DX-** (the pairing on screen) brand not stated 16,500 Btu/h4.84 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 7AH1AE36PX-** (the pairing on screen) | — | 15,9004.66 | 34,40010.08 | 36,00010.55 | 46% | 1.90 | NC | 4 |
| 7AH1AV36PX-** (the pairing on screen) | — | 15,7004.60 | 34,20010.02 | 36,00010.55 | 46% | 1.90 | NC | 4 |
| 7AH2AE36PX-** (the pairing on screen) | — | 16,6004.86 | 35,60010.43 | 35,40010.37 | 47% | 2.04 | NC | 4 |
| 7AH2AE42PX*** (the pairing on screen) | — | 16,3004.78 | 34,0009.96 | 36,00010.55 | 48% | 2.06 | NC | 4 |
| 7AH2AV42PXC*** (the pairing on screen) | — | 16,3004.78 | 34,20010.02 | 36,00010.55 | 48% | 2.06 | NC | 4 |
| 7AH1RE42DX-** (the pairing on screen) | — | 16,5004.84 | 31,4009.20 | 36,00010.55 | 53% | 1.96 | NC | 3 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
- Are Allied and Concord heat pumps the same?39 shared model numbers
- Are Allied and Ducane heat pumps the same?39 shared model numbers
- Are Allied and Breeze33 heat pumps the same?14 shared model numbers
- Are Breeze33 and Concord heat pumps the same?14 shared model numbers
- Are Breeze33 and Ducane heat pumps the same?14 shared model numbers
- Are Concord and Ducane heat pumps the same?39 shared model numbers
Model number as listed
- 7HP14F36P-**A 135 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- 7HP14F36P-**A first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 3, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read