GSZC703610A
GSZC703610A is in the certified data.
Its certified full-speed heating output at 5°F is 17,000 Btu/h4.98 kW, 50% of its 47°F rating, depending on the pairing.
Goodman · central heat pump
GSZC703610A is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Central
- Two-stage
- Canada
Certified heating and cooling
Heating at 47°F
34,0009.96NR
No 47°F rating for this pairing.
21,0006.15NR at 17°F
17,0004.98NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 34,000 Btu/h9.96 kW of heat at 47°F, 21,000 Btu/h6.15 kW at 17°F, and 17,000 Btu/h4.98 kW at 5°F, 50% of its 47°F rating. It delivers 34,800 Btu/h10.20 kW of cooling at 95°F. At 5°F that is 9,500 Btu/h2.78 kW short of the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 21,800 Btu/h6.39 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 211641719 · listed by Goodman · certified Apr 22, 2026 · 4 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 17,0004.98 kW | −36% | 2.00 | |
| 17°Fone compressor speed | 21,0006.15 kW | −20% | NR | |
| 47°Fone compressor speed | 34,0009.96 kW | −3% | NR | |
| 95°Fcooling, full load | 34,80010.20 kW | — | NR |
EER2 12.5 in that test. SEER2 17.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.49kW
- Electrical input in the 95°F cooling test
- 2.78kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 17,000 Btu/h4.98 kWNR
- This unit at 5°F median across its pairings
- 17,000 Btu/h4.98 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 8% of them, at number 414 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- 5TWR6036A1Trane · 17,200 Btu/h
- 5TWX6036A1Trane · 17,200 Btu/h
- MHP17036A-**AMRCOOL · 17,200 Btu/h
- MOVA-36HN10-M152LMidea · 16,900 Btu/h
- ML14KP1-036-230ALennox · 16,800 Btu/h
- 7HP14F36P-**AAllied, Breeze33 + 2 more · 16,600 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for GSZC703610A
11 pairings · 11 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 34,000 Btu/h9.96 kWNR | 33,800–34,000 Btu/h9.91–9.96 kW |
| Heat output at 17°F full speed | 21,000 Btu/h6.15 kWNR | 21,000 Btu/h6.15 kW |
| Heat output at 5°F full speed | 17,000 Btu/h4.98 kWNR | 17,000 Btu/h4.98 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 50%NR | |
| COP at 5°F full speed | 2.00NR | 1.90–2.00 |
| HSPF2 Region IV | 8.1NR | 8.1–8.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 34,800 Btu/h10.20 kWNR | 34,600–34,800 Btu/h10.14–10.20 kW |
| EER2 at 95°F | 12.5NR | 12.5 |
| SEER2 cooling season | 17.2NR | 17.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | AMVT42CP1400A* | 11 indoor units |
| Furnace | No furnace | 2 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | Canada | Canada |
| Model string as certified | GSZC703610A* | |
Pairings, by indoor-unit class
11 indoor units · 11 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 3 indoor units
-
CAPTA4230*4A* (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
CAPTA4230*4B* (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
CHPTA3630*4A* (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CAPTA4230*4A* (the pairing on screen) | — | 17,0004.98 | 34,0009.96 | 34,80010.20 | 50% | 2.00 | NC | 1 |
| CAPTA4230*4B* (the pairing on screen) | — | 17,0004.98 | 34,0009.96 | 34,80010.20 | 50% | 2.00 | NC | 1 |
| CHPTA3630*4A* (the pairing on screen) | — | 17,0004.98 | 33,8009.91 | 34,60010.14 | 50% | 1.90 | NC | 1 |
Air handler · 8 indoor units
-
AMVT42CP1400A* (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
AMVT42CP1400B* (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
CAPTA4230*4A*+MBVB16CP1X00A* (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
CAPTA4230*4A*+MBVC1601**-1A* (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
CAPTA4230*4B*+MBVB16CP1X00A* (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
CAPTA4230*4B*+MBVC1601**-1A* (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
CHPTA3630*4A*+MBVB16CP1X00A* (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
CHPTA3630*4A*+MBVC1601**-1A* (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| AMVT42CP1400A* (the pairing on screen) | — | 17,0004.98 | 34,0009.96 | 34,80010.20 | 50% | 2.00 | NC | 1 |
| AMVT42CP1400B* (the pairing on screen) | — | 17,0004.98 | 34,0009.96 | 34,80010.20 | 50% | 2.00 | NC | 1 |
| CAPTA4230*4A*+MBVB16CP1X00A* (the pairing on screen) | — | 17,0004.98 | 34,0009.96 | 34,80010.20 | 50% | 2.00 | NC | 1 |
| CAPTA4230*4A*+MBVC1601**-1A* (the pairing on screen) | — | 17,0004.98 | 34,0009.96 | 34,80010.20 | 50% | 2.00 | NC | 1 |
| CAPTA4230*4B*+MBVB16CP1X00A* (the pairing on screen) | — | 17,0004.98 | 34,0009.96 | 34,80010.20 | 50% | 2.00 | NC | 1 |
| CAPTA4230*4B*+MBVC1601**-1A* (the pairing on screen) | — | 17,0004.98 | 34,0009.96 | 34,80010.20 | 50% | 2.00 | NC | 1 |
| CHPTA3630*4A*+MBVB16CP1X00A* (the pairing on screen) | — | 17,0004.98 | 33,8009.91 | 34,80010.20 | 50% | 1.90 | NC | 1 |
| CHPTA3630*4A*+MBVC1601**-1A* (the pairing on screen) | — | 17,0004.98 | 33,8009.91 | 34,80010.20 | 50% | 1.90 | NC | 1 |
Sold as, and units with identical certified values
Variants of the same model number
3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
Other model numbers with identical certified values
3 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 22, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read