5TWR6036A1
5TWR6036A1 is in the certified data.
Its certified full-speed heating output at 5°F is 16,900–17,600 Btu/h4.95–5.16 kW, 53–58% of its 47°F rating, depending on the pairing.
Trane · central heat pump
5TWR6036A1 is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Central
- Single stage
- US and Canada
Certified heating and cooling
Heating at 47°F
31,4009.20NR
No 47°F rating for this pairing.
21,6006.33NR at 17°F
17,2005.04NR at 5°F
Btu/hkW, certified
2.38NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 31,400 Btu/h9.20 kW of heat at 47°F, 21,600 Btu/h6.33 kW at 17°F, and 17,200 Btu/h5.04 kW at 5°F, 55% of its 47°F rating. It delivers 34,800 Btu/h10.20 kW of cooling at 95°F. At 5°F that is 9,300 Btu/h2.73 kW short of the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 21,800 Btu/h6.39 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218107684 · listed by Trane · certified Mar 26, 2026 · 8 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 17,2005.04 kW | −35% | 2.38 | |
| 17°Fone compressor speed | 21,6006.33 kW | −18% | NR | |
| 47°Fone compressor speed | 31,4009.20 kW | −11% | NR | |
| 95°Fcooling, full load | 34,80010.20 kW | — | NR |
EER2 12.0 in that test. SEER2 16.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.12kW
- Electrical input in the 95°F cooling test
- 2.90kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 17,200 Btu/h5.04 kWNR
- This unit at 5°F median across its pairings
- 17,200 Btu/h5.04 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 9% of them, at number 411 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- 5TWR5036A1Trane · 17,300 Btu/h
- 5TWX5036A1Trane · 17,300 Btu/h
- BHP17L36P-**ABlueridge · 17,300 Btu/h
- 5TWX6036A1Trane · 17,200 Btu/h
- MHP17036A-**AMRCOOL · 17,200 Btu/h
- GSZC703610AGoodman · 17,000 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 5TWR6036A1
371 pairings · 371 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 31,400 Btu/h9.20 kWNR | 29,800–32,200 Btu/h8.73–9.44 kW |
| Heat output at 17°F full speed | 21,600 Btu/h6.33 kWNR | 21,000–22,200 Btu/h6.15–6.51 kW |
| Heat output at 5°F full speed | 17,200 Btu/h5.04 kWNR | 16,900–17,600 Btu/h4.95–5.16 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 55%NR | |
| COP at 5°F full speed | 2.38NR | 2.23–2.49 |
| HSPF2 Region IV | 8.1NR | 7.8–8.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 34,800 Btu/h10.20 kWNR | 31,600–35,200 Btu/h9.26–10.32 kW |
| EER2 at 95°F | 12.0NR | 11.5–12.0 |
| SEER2 cooling season | 16.0NR | 15.2–16.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Single stage | |
| Indoor unit | 5PX*C009AS3+TSTAT | 56 indoor units |
| Furnace | S8X1C080M5PSC | 83 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | US and Canada |
| Model string as certified | 5TWR6036A1 | |
Pairings, by indoor-unit class
56 indoor units · 371 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 10 indoor units
-
5PX*B006AS3+TSTAT (the pairing on screen) brand not stated 17,200 Btu/h5.04 kWat 5°F, full speed
-
5TXCB006AS3+TSTAT (the pairing on screen) brand not stated 17,200 Btu/h5.04 kWat 5°F, full speed
-
5PX*BD06AS3+TSTAT (the pairing on screen) brand not stated 17,300 Btu/h5.07 kWat 5°F, full speed
-
5PX*C007AS3+TSTAT (the pairing on screen) brand not stated 17,300 Btu/h5.07 kWat 5°F, full speed
-
5PX*C009AS3+TSTAT (the pairing on screen) brand not stated 17,200 Btu/h5.04 kWat 5°F, full speed
-
5TXCC007AS3+TSTAT (the pairing on screen) brand not stated 17,300 Btu/h5.07 kWat 5°F, full speed
-
5TXCC009AS3+TSTAT (the pairing on screen) brand not stated 17,200 Btu/h5.04 kWat 5°F, full speed
-
5PX*C005AS3+TSTAT (the pairing on screen) brand not stated 17,200 Btu/h5.04 kWat 5°F, full speed
-
5TXCC005AS3+TSTAT (the pairing on screen) brand not stated 17,200 Btu/h5.04 kWat 5°F, full speed
-
5PX*CD07AS3+TSTAT (the pairing on screen) brand not stated 17,500 Btu/h5.13 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5PX*B006AS3+TSTAT (the pairing on screen) | — | 17,2005.04 | 31,2009.14 | 33,6009.85 | 55% | 2.36 | NC | 33 |
| 5TXCB006AS3+TSTAT (the pairing on screen) | — | 17,2005.04 | 31,4009.20 | 33,6009.85 | 55% | 2.36 | NC | 33 |
| 5PX*BD06AS3+TSTAT (the pairing on screen) | — | 17,3005.07 | 31,6009.26 | 33,4009.79 | 55% | 2.35 | NC | 29 |
| 5PX*C007AS3+TSTAT (the pairing on screen) | — | 17,3005.07 | 31,6009.26 | 34,20010.02 | 55% | 2.38 | NC | 21 |
| 5PX*C009AS3+TSTAT (the pairing on screen) | — | 17,2005.04 | 31,2009.14 | 34,40010.08 | 55% | 2.38 | NC | 21 |
| 5TXCC007AS3+TSTAT (the pairing on screen) | — | 17,3005.07 | 31,4009.20 | 34,0009.96 | 55% | 2.37 | NC | 21 |
| 5TXCC009AS3+TSTAT (the pairing on screen) | — | 17,2005.04 | 31,2009.14 | 34,40010.08 | 55% | 2.38 | NC | 21 |
| 5PX*C005AS3+TSTAT (the pairing on screen) | — | 17,2005.04 | 31,0009.09 | 33,0009.67 | 55% | 2.32 | NC | 19 |
| 5TXCC005AS3+TSTAT (the pairing on screen) | — | 17,2005.04 | 31,0009.09 | 33,0009.67 | 55% | 2.32 | NC | 19 |
| 5PX*CD07AS3+TSTAT (the pairing on screen) | — | 17,5005.13 | 32,0009.38 | 34,0009.96 | 55% | 2.31 | NC | 17 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 26, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read