BHP17L36P-**A
BHP17L36P-**A is in the certified data.
Its certified full-speed heating output at 5°F is 16,800–19,100 Btu/h4.92–5.60 kW, 50–56% of its 47°F rating, depending on the pairing.
Blueridge · central heat pump
BHP17L36P-**A is in the certified data as of Sep 19, 2026. BHP17L36P-**A changed its certified heat output at 17°F on 2 pairings in the certified data between September 2024 and November 2024. The new figure is higher on all 2.
- 36,000 Btu (3-ton)
- Central
- Single stage
- US and Canada
Certified heating and cooling
Heating at 47°F
33,0009.67NR
No 47°F rating for this pairing.
21,8006.39NR at 17°F
17,3005.07NR at 5°F
Btu/hkW, certified
2.16NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 33,000 Btu/h9.67 kW of heat at 47°F, 21,800 Btu/h6.39 kW at 17°F, and 17,300 Btu/h5.07 kW at 5°F, 52% of its 47°F rating. It delivers 36,000 Btu/h10.55 kW of cooling at 95°F. At 5°F that is 9,200 Btu/h2.70 kW short of the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 23,000 Btu/h6.74 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 211736731 · listed by BLUERIDGE · certified Oct 27, 2025 · 2 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 17,3005.07 kW | −34% | 2.16 | |
| 17°Fone compressor speed | 21,8006.39 kW | −17% | NR | |
| 47°Fone compressor speed | 33,0009.67 kW | −6% | NR | |
| 95°Fcooling, full load | 36,00010.55 kW | — | NR |
EER2 13.0 in that test. SEER2 16.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.35kW
- Electrical input in the 95°F cooling test
- 2.77kW
- Seasonal average heating COP
- 2.29
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 17,300 Btu/h5.07 kWNR
- This unit at 5°F median across its pairings
- 17,300 Btu/h5.07 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 10% of them, at number 407 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- 4HP17L36P-**AAC Pro, Allied + 4 more · 17,300 Btu/h
- 5TWR5036A1Trane · 17,300 Btu/h
- 5TWX5036A1Trane · 17,300 Btu/h
- 5TWR6036A1Trane · 17,200 Btu/h
- 5TWX6036A1Trane · 17,200 Btu/h
- MHP17036A-**AMRCOOL · 17,200 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for BHP17L36P-**A
131 pairings · 131 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 33,000 Btu/h9.67 kWNR | 32,400–36,000 Btu/h9.50–10.55 kW |
| Heat output at 17°F full speed | 21,800 Btu/h6.39 kWNR | 21,400–23,800 Btu/h6.27–6.98 kW |
| Heat output at 5°F full speed | 17,300 Btu/h5.07 kWNR | 16,800–19,100 Btu/h4.92–5.60 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 52%NR | |
| COP at 5°F full speed | 2.16NR | 2.08–2.34 |
| HSPF2 Region IV | 7.8NR | 7.8–8.7 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 36,000 Btu/h10.55 kWNR | 35,000–36,000 Btu/h10.26–10.55 kW |
| EER2 at 95°F | 13.0NR | 12.2–13.5 |
| SEER2 cooling season | 16.2NR | 15.2–16.8 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Single stage | |
| Indoor unit | BH1P51C*+TDR+TXV | 26 indoor units |
| Furnace | BG921UH090CE16 | 26 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | BHP17L36P-**A | |
Pairings, by indoor-unit class
26 indoor units · 131 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 10 indoor units
-
BC1P36A+TDR+TXV (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
BC742HCT-0*+TDR (the pairing on screen) brand not stated 17,900 Btu/h5.25 kWat 5°F, full speed
-
BC748CCT-0*+TDR (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
BC750/60CCT-0*+TDR (the pairing on screen) brand not stated 17,200 Btu/h5.04 kWat 5°F, full speed
-
BC751HCT-0*+TDR (the pairing on screen) brand not stated 17,400 Btu/h5.10 kWat 5°F, full speed
-
BH1P51C*+TDR+TXV (the pairing on screen) brand not stated 17,400 Btu/h5.10 kWat 5°F, full speed
-
BC1P36B+TDR+TXV (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
BC4X36B+TDR (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
BC736CBT-0*+TDR (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
-
BC742HBT-0*+TDR (the pairing on screen) brand not stated 18,450 Btu/h5.41 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| BC1P36A+TDR+TXV (the pairing on screen) | — | 17,0004.98 | 33,6009.85 | 35,70010.46 | 51% | 2.13 | NC | 12 |
| BC742HCT-0*+TDR (the pairing on screen) | — | 17,9005.25 | 33,0009.67 | 36,00010.55 | 55% | 2.20 | NC | 9 |
| BC748CCT-0*+TDR (the pairing on screen) | — | 17,0004.98 | 33,6009.85 | 36,00010.55 | 50% | 2.14 | NC | 9 |
| BC750/60CCT-0*+TDR (the pairing on screen) | — | 17,2005.04 | 32,6009.55 | 35,40010.37 | 53% | 2.12 | NC | 9 |
| BC751HCT-0*+TDR (the pairing on screen) | — | 17,4005.10 | 33,2009.73 | 36,00010.55 | 53% | 2.18 | NC | 9 |
| BH1P51C*+TDR+TXV (the pairing on screen) | — | 17,4005.10 | 33,2009.73 | 36,00010.55 | 53% | 2.18 | NC | 9 |
| BC1P36B+TDR+TXV (the pairing on screen) | — | 17,0004.98 | 33,6009.85 | 35,80010.49 | 51% | 2.14 | NC | 8 |
| BC4X36B+TDR (the pairing on screen) | — | 17,0004.98 | 33,6009.85 | 35,80010.49 | 51% | 2.14 | NC | 8 |
| BC736CBT-0*+TDR (the pairing on screen) | — | 17,0004.98 | 33,6009.85 | 35,80010.49 | 51% | 2.14 | NC | 8 |
| BC742HBT-0*+TDR (the pairing on screen) | — | 18,4505.41 | 33,2009.73 | 36,00010.55 | 55% | 2.25 | NC | 8 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- BHP17L36P-**A 131 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- BHP17L36P-**A changed its certified heat output at 17°F on 2 pairings in the certified data between September 2024 and November 2024. The new figure is higher on all 2.
- BHP17L36P-**A was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Oct 27, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read