7SCP18V60P-**A
7SCP18V60P-**A is in the certified data.
Its certified full-speed heating output at 5°F is 39,000–45,000 Btu/h11.43–13.19 kW, 73–90% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Allied, Concord + 1 more · central heat pump
7SCP18V60P-**A is in the certified data as of Sep 19, 2026. 7SCP18V60P-**A changed its certified COP at 5°F on 3 pairings from 1.75 to 1.80 in the certified data between August 2025 and September 2026.
- 42,000 Btu (3.5-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
47,50013.92NR
No 47°F rating for this pairing.
39,50011.58NR at 17°F
40,00011.72NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 47,500 Btu/h13.92 kW of heat at 47°F, 39,500 Btu/h11.58 kW at 17°F, and 40,000 Btu/h11.72 kW at 5°F, 84% of its 47°F rating. It delivers 43,500 Btu/h12.75 kW of cooling at 95°F. At 5°F that is 7,000 Btu/h2.05 kW above the example heating load of 33,000 Btu/h9.67 kW; at 95°F it is 26,500 Btu/h7.77 kW above the example cooling load of 17,000 Btu/h4.98 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,400 sq ft where winters reach 5°F: heating runs from 33,000 Btu/h9.67 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 17,000 Btu/h4.98 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216769782 · listed by Concord · certified Jan 20, 2026 · 12 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 40,00011.72 kW | +21% | 1.80 | |
| 17°Ffull speed | 39,50011.58 kW | +27% | NR | |
| 47°Fnormal speed | 47,50013.92 kW | +8% | NR | |
| 95°Fcooling, full load | 43,50012.75 kW | — | NR |
EER2 10.0 in that test. SEER2 16.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 6.51kW
- Electrical input in the 95°F cooling test
- 4.35kW
- Seasonal average heating COP
- 2.49
These exclude backup resistance heat.
How it compares with other 42,000 Btu heat pumps
3.5-ton central models
- This pairing at 5°F
- 40,000 Btu/h11.72 kWNR
- This unit at 5°F median across its pairings
- 40,000 Btu/h11.72 kW
- Median of 3.5-ton central models at 5°F
- 33,000 Btu/h9.67 kW
- Models in this group
- 222
This unit is above 72% of them, at number 63 of 222 by heat at 5°F. The middle half of the group runs 20,000 to 40,000 Btu/h.
Closest models by heat at 5°F
- CENTRAL-48-HP-C-230B00-OMRCOOL · 41,000 Btu/h
- MO1HE-H42B-2AMidea · 41,000 Btu/h
- 1U60T3PE*HEHaier · 40,000 Btu/h
- DIRM4-48CS19-OUDirect Air · 40,000 Btu/h
- EL18KSLV-060-230ALennox · 40,000 Btu/h
- MVP-48-HP-C-230A00-OMRCOOL · 40,000 Btu/h
Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 7SCP18V60P-**A
573 pairings · 573 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 47,500 Btu/h13.92 kWNR | 47,000–56,500 Btu/h13.77–16.56 kW |
| Heat output at 17°F full speed | 39,500 Btu/h11.58 kWNR | 38,500–45,000 Btu/h11.28–13.19 kW |
| Heat output at 5°F full speed | 40,000 Btu/h11.72 kWNR | 39,000–45,000 Btu/h11.43–13.19 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 84%NR | |
| COP at 5°F full speed | 1.80NR | 1.75–1.95 |
| HSPF2 Region IV | 8.5NR | 8.1–9.6 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 43,500 Btu/h12.75 kWNR | 42,500–55,500 Btu/h12.46–16.27 kW |
| EER2 at 95°F | 10.0NR | 9.6–11.7 |
| SEER2 cooling season | 16.0NR | 15.2–18.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | 7EH48CX-**+TDR | 29 indoor units |
| Furnace | 97G2UH110CV20* | 40 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 7SCP18V60P-**A | |
Pairings, by indoor-unit class
29 indoor units · 573 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 5 indoor units
-
7EH42CX-**+TDR (the pairing on screen) brand not stated 39,500 Btu/h11.58 kWat 5°F, full speed
-
7EH48CX-**+TDR (the pairing on screen) brand not stated 40,000 Btu/h11.72 kWat 5°F, full speed
-
7EH50/60CX-**+TDR (the pairing on screen) brand not stated 40,500 Btu/h11.87 kWat 5°F, full speed
-
7EH51CX-**+TDR (the pairing on screen) brand not stated 40,500 Btu/h11.87 kWat 5°F, full speed
-
7E[C,U]50/60CX-**+TDR (the pairing on screen) brand not stated 41,000 Btu/h12.02 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 7EH42CX-**+TDR (the pairing on screen) | — | 39,50011.58 | 47,50013.92 | 44,00012.90 | 83% | 1.80 | Yes | 57 |
| 7EH48CX-**+TDR (the pairing on screen) | — | 40,00011.72 | 47,50013.92 | 43,50012.75 | 83% | 1.80 | Yes | 57 |
| 7EH50/60CX-**+TDR (the pairing on screen) | — | 40,50011.87 | 54,50015.97 | 53,00015.53 | 74% | 1.85 | Yes | 39 |
| 7EH51CX-**+TDR (the pairing on screen) | — | 40,50011.87 | 54,50015.97 | 53,00015.53 | 74% | 1.85 | Yes | 36 |
| 7E[C,U]50/60CX-**+TDR (the pairing on screen) | — | 41,00012.02 | 54,50015.97 | 51,00014.95 | 76% | 1.80 | Yes | 33 |
Air handler · 5 indoor units
-
7E[C,U]48CX-**+TDR (the pairing on screen) brand not stated 39,500 Btu/h11.58 kWat 5°F, full speed
-
7E[C,U]49CX-**+TDR (the pairing on screen) brand not stated 39,500 Btu/h11.58 kWat 5°F, full speed
-
7E[C,U]60CX-**+TDR (the pairing on screen) brand not stated 40,500 Btu/h11.87 kWat 5°F, full speed
-
7ED48CX-**+TDR (the pairing on screen) brand not stated 39,500 Btu/h11.58 kWat 5°F, full speed
-
7EH42BX-**+TDR (the pairing on screen) brand not stated 39,000 Btu/h11.43 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 7E[C,U]48CX-**+TDR (the pairing on screen) | — | 39,50011.58 | 47,50013.92 | 44,00012.90 | 83% | 1.80 | Yes | 60 |
| 7E[C,U]49CX-**+TDR (the pairing on screen) | — | 39,50011.58 | 47,50013.92 | 45,50013.33 | 82% | 1.85 | Yes | 60 |
| 7E[C,U]60CX-**+TDR (the pairing on screen) | — | 40,50011.87 | 55,00016.12 | 54,50015.97 | 74% | 1.90 | Yes | 42 |
| 7ED48CX-**+TDR (the pairing on screen) | — | 39,50011.58 | 47,50013.92 | 44,50013.04 | 82% | 1.90 | Yes | 27 |
| 7EH42BX-**+TDR (the pairing on screen) | — | 39,00011.43 | 47,50013.92 | 45,00013.19 | 82% | 1.90 | Yes | 21 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
- Are Allied and Concord heat pumps the same?39 shared model numbers
- Are Allied and Ducane heat pumps the same?39 shared model numbers
- Are Concord and Ducane heat pumps the same?39 shared model numbers
Model number as listed
- 7SCP18V60P-**A 573 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- 7SCP18V60P-**A changed its certified COP at 5°F on 3 pairings from 1.75 to 1.80 in the certified data between August 2025 and September 2026.
- 7SCP18V60P-**A changed its certified heat output at 47°F on 507 pairings in the certified data between August 2025 and September 2026. The new figure is higher on 498 and lower on 9.
- 7SCP18V60P-**A changed its certified heat output at 47°F on 12 pairings in the certified data between March 2025 and May 2025. The new figure is lower on all 12.
- 7SCP18V60P-**A changed its certified heat output at 47°F on 18 pairings in the certified data between February 2025 and March 2025. The new figure is higher on 4 and lower on 14.
- 7SCP18V60P-**A first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jan 20, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read