Heat Pump List

Tools

AC024FCUDCG

AC024FCUDCG is in the certified data.

Its certified full-speed heating output at 5°F is 23,000–24,400 Btu/h, 92–98% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Samsung · central heat pump

AC024FCUDCG is in the certified data as of Sep 19, 2026.

2 certified pairings with 2 different figures. See all

Certified heating and cooling

Heating at 47°F

25,000

17,100 at 17°F

23,000 at 5°F

Btu/h, certified

1.88 COP at 5°F

Cooling at 95°F

24,000

Btu/h, certified

EER2 11.5 at 95°F

SEER2 16.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for AC024FCUDCG, by outdoor temperature Heating: 23,000 Btu/h at 5°F, 17,100 Btu/h at 17°F, 25,000 Btu/h at 47°F. Cooling: 24,000 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 25,000 Btu/h 23,000 5°F 17,100 17°F 25,000 47°F 24,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 25,000 Btu/h of heat at 47°F, 17,100 Btu/h at 17°F, and 23,000 Btu/h at 5°F, 92% of its 47°F rating. It delivers 24,000 Btu/h of cooling at 95°F. At 5°F that is 4,000 Btu/h above the example heating load of 19,000 Btu/h; at 95°F it is 14,500 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 218325260 · listed by Samsung · certified Apr 22, 2026 · 1 pairing carries these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 23,0006.74 kW +21% 1.88
17°Ffull speed 17,1005.01 kW −11% NR
47°Fhigh stage 25,0007.33 kW +4% NR
95°Fcooling, full load 24,0007.03 kW — NR

EER2 11.5 in that test. SEER2 16.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.59kW
Electrical input in the 95°F cooling test
2.09kW
Seasonal average heating COP
2.40

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
23,000 Btu/h
This unit at 5°F median across its pairings
23,000 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 84% of them, at number 88 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for AC024FCUDCG

2 pairings · 2 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for AC024FCUDCG
This pairingAll pairings
Heating
Heat output at 47°F high stage 25,000 Btu/h 25,000 Btu/h
Heat output at 17°F full speed 17,100 Btu/h 17,100–18,100 Btu/h
Heat output at 5°F full speed 23,000 Btu/h 23,000–24,400 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 92%
COP at 5°F full speed 1.88 1.82–1.88
HSPF2 Region IV 8.2 8.2
Cooling
Cooling capacity at 95°F full-load test 24,000 Btu/h 24,000 Btu/h
EER2 at 95°F 11.5 11.0–11.5
SEER2 cooling season 16.5 16.0–16.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Two-stage
Indoor unit 7AH2AV24PXC** 2 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified AC024FCUDCG

Pairings, by indoor-unit class

2 indoor units · 2 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 2 indoor units

  1. 7AH2AV24PXC** (the pairing on screen) brand not stated 23,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 25,000 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 92% · COP 1.88

  2. FEMG33A25S001R brand not stated 24,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 25,000 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 98% · COP 1.82

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
7AH2AV24PXC** (the pairing on screen) — 23,000 25,000 24,000 92% 1.88 Yes 1
FEMG33A25S001R — 24,400 25,000 24,000 98% 1.82 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 2 of 2 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Apr 22, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “AC024FCUDCG — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/ac024fcudcg