ACIQ-18Z-HH-M2B
ACIQ-18Z-HH-M2B is in the certified data.
Its certified full-speed heating output at 5°F is 19,000–19,700 Btu/h5.57–5.77 kW, 95–99% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
1HVAC, ACiQ + 3 more · mini-split heat pump
ACIQ-18Z-HH-M2B is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
20,0005.86NR
No 47°F rating for this pairing.
15,5004.54NR at 17°F
19,3005.66NR at 5°F
Btu/hkW, certified
1.88NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 20,000 Btu/h5.86 kW of heat at 47°F, 15,500 Btu/h4.54 kW at 17°F, and 19,300 Btu/h5.66 kW at 5°F, 97% of its 47°F rating. It delivers 19,000 Btu/h5.57 kW of cooling at 95°F. At 5°F that is 5,300 Btu/h1.55 kW above the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 12,000 Btu/h3.52 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 207825566 · listed by 1HVAC · certified Jun 13, 2026 · 5 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 19,3005.66 kW | +36% | 1.88 | |
| 17°Ffull speed | 15,5004.54 kW | +5% | NR | |
| 47°Fnormal speed | 20,0005.86 kW | +11% | NR | |
| 95°Fcooling, full load | 19,0005.57 kW | — | NR |
EER2 12.25 in that test. SEER2 20.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.01kW
- Electrical input in the 95°F cooling test
- 1.55kW
- Seasonal average heating COP
- 2.80
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 19,300 Btu/h5.66 kWNR
- This unit at 5°F median across its pairings
- 19,300 Btu/h5.66 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 89% of them, at number 118 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- SUPMZ18R454Supreme · 19,800 Btu/h
- AE-X18CHUSharp · 19,500 Btu/h
- YPAS18BLFASDQ1York · 19,400 Btu/h
- H18FMHD3XPCTCL · 19,300 Btu/h
- MLB018S4M-1PLennox · 19,300 Btu/h
- RUZ-AK18NLHZMitsubishi Electric · 19,300 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for ACIQ-18Z-HH-M2B
15 pairings · 15 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 20,000 Btu/h5.86 kWNR | 20,000 Btu/h5.86 kW |
| Heat output at 17°F full speed | 15,500 Btu/h4.54 kWNR | 15,000–16,000 Btu/h4.40–4.69 kW |
| Heat output at 5°F full speed | 19,300 Btu/h5.66 kWNR | 19,000–19,700 Btu/h5.57–5.77 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 97%NR | |
| COP at 5°F full speed | 1.88NR | 1.85–1.90 |
| HSPF2 Region IV | 9.6NR | 9.3–9.8 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 19,000 Btu/h5.57 kWNR | 19,000 Btu/h5.57 kW |
| EER2 at 95°F | 12.25NR | 12.0–12.5 |
| SEER2 cooling season | 20.5NR | 19.0–22.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | ACIQ-18Z-HH-M2B | |
Pairings, by indoor-unit class
15 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) 1HVAC 19,300 Btu/h5.66 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | 1HVAC | 19,3005.66 | 20,0005.86 | 19,0005.57 | 97% | 1.88 | Yes | 15 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
- Are 1HVAC and ACiQ heat pumps the same?76 shared model numbers
- Are 1HVAC and DIYCool heat pumps the same?63 shared model numbers
- Are 1HVAC and PolarWave heat pumps the same?52 shared model numbers
- Are 1HVAC and Stealth heat pumps the same?34 shared model numbers
Model number as listed
- ACIQ-18Z-HH-M2B 15 pairings
Variants of the same model number
19 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 19MPC2-HH-AMulti MFG
- A-KMH18DV-1Kerr
- A-VMH18DV-1Century · Comfort-Aire
- BMS500-AAM018-1CSXHCBosch
- BZ33-HYP182Z2-G2-PBreeze33
- C28MC218H22CanAir
- CCOXHAMZ218HPCustom Comfort
- CH-HPR19M-230VOC&H · Cooper&Hunter
- CVH-18-2SHComfortStar
- DEA18HOM25230X3Elios
- DIRM-18HXPRO28-2ZDirect Air
- DMA18HOM25230X3MoovAir
- M2H18H/O4S4PTrust Air Conditioners
- MHMZ218DAConforto · EMI
- MST183E23MHAAFranklin
- MST183F25MHAAFranklin
- ODUM2OI-18HFN1-MKepler
- SENA-18HF-MOBSenville
18 of 19 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 13, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read