ACIQ-18ZPL-HP230C
ACIQ-18ZPL-HP230C is in the certified data.
Its certified full-speed heating output at 5°F is 17,000–18,000 Btu/h4.98–5.28 kW, 88–100% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
1HVAC and ACiQ · mini-split heat pump
ACIQ-18ZPL-HP230C is in the certified data as of Sep 19, 2026. ACIQ-18ZPL-HP230C changed its certified heat output at 17°F on 2 pairings from 16,600 Btu/h to 18,000 Btu/h in the certified data between December 2025 and September 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
20,0005.86NR
No 47°F rating for this pairing.
14,5004.25NR at 17°F
17,5005.13NR at 5°F
Btu/hkW, certified
1.89NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 20,000 Btu/h5.86 kW of heat at 47°F, 14,500 Btu/h4.25 kW at 17°F, and 17,500 Btu/h5.13 kW at 5°F, 88% of its 47°F rating. It delivers 16,700 Btu/h4.89 kW of cooling at 95°F. At 5°F that is 3,500 Btu/h1.03 kW above the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 9,700 Btu/h2.84 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216032294 · listed by 1HVAC · certified Mar 4, 2025 · 3 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 17,5005.13 kW | +23% | 1.89 | |
| 17°Ffull speed | 14,5004.25 kW | −2% | NR | |
| 47°Fnormal speed | 20,0005.86 kW | +11% | NR | |
| 95°Fcooling, full load | 16,7004.89 kW | — | NR |
EER2 12.5 in that test. SEER2 20.6 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.71kW
- Electrical input in the 95°F cooling test
- 1.34kW
- Seasonal average heating COP
- 3.58
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 17,500 Btu/h5.13 kWNR
- This unit at 5°F median across its pairings
- 17,500 Btu/h5.13 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 67% of them, at number 369 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- 2KARDA18SZO20Karda and PerfectAire · 17,700 Btu/h
- DIRM-18HXPRO28-1ZDirect Air · 17,700 Btu/h
- ODUMOX430-17HFN1MT0WKepler · 17,700 Btu/h
- BMS500-AAS018-1CSXHDBosch · 17,500 Btu/h
- BZ33-HYP18OUT2-454-G3-PBreeze33 · 17,500 Btu/h
- CU-XE18WKUAPanasonic · 17,500 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for ACIQ-18ZPL-HP230C
12 pairings · 12 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 20,000 Btu/h5.86 kWNR | 18,000–20,000 Btu/h5.28–5.86 kW |
| Heat output at 17°F full speed | 14,500 Btu/h4.25 kWNR | 14,400–18,000 Btu/h4.22–5.28 kW |
| Heat output at 5°F full speed | 17,500 Btu/h5.13 kWNR | 17,000–18,000 Btu/h4.98–5.28 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 88%NR | |
| COP at 5°F full speed | 1.89NR | 1.86–2.10 |
| HSPF2 Region IV | 12.2NR | 10.3–12.3 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 16,700 Btu/h4.89 kWNR | 16,000–18,000 Btu/h4.69–5.28 kW |
| EER2 at 95°F | 12.5NR | 12.0–13.0 |
| SEER2 cooling season | 20.6NR | 18.4–21.7 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | SCC-1218-HH-MB | 7 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | ACIQ-18ZPL-HP230C | |
Pairings, by indoor-unit class
7 indoor units · 12 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 7 indoor units
-
ACIQ-18CC-HH-MC (the pairing on screen) 1HVAC 17,000 Btu/h4.98 kWat 5°F, full speed
-
ACIQ-18CD-HH-MC (the pairing on screen) 1HVAC 18,000 Btu/h5.28 kWat 5°F, full speed
-
ACIQ-18FM-HH-MD (the pairing on screen) 1HVAC 17,000 Btu/h4.98 kWat 5°F, full speed
-
ACIQ-18W-HH-MD (the pairing on screen) 1HVAC 18,000 Btu/h5.28 kWat 5°F, full speed
-
SCC-1218-HH-MB (the pairing on screen) 1HVAC 17,500 Btu/h5.13 kWat 5°F, full speed
-
ACIQ-018W-BL-MD (the pairing on screen) ACIQ 18,000 Btu/h5.28 kWat 5°F, full speed
-
SCC-18-HH-MB (the pairing on screen) ACIQ 17,500 Btu/h5.13 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| ACIQ-18CC-HH-MC (the pairing on screen) | 1HVAC | 17,0004.98 | 19,0005.57 | 16,0004.69 | 89% | 1.90 | Yes | 2 |
| ACIQ-18CD-HH-MC (the pairing on screen) | 1HVAC | 18,0005.28 | 19,5005.71 | 17,5005.13 | 92% | 2.10 | Yes | 2 |
| ACIQ-18FM-HH-MD (the pairing on screen) | 1HVAC | 17,0004.98 | 19,0005.57 | 17,0004.98 | 89% | 1.86 | Yes | 2 |
| ACIQ-18W-HH-MD (the pairing on screen) | 1HVAC | 18,0005.28 | 18,0005.28 | 18,0005.28 | 100% | 1.92 | Yes | 2 |
| SCC-1218-HH-MB (the pairing on screen) | 1HVAC | 17,5005.13 | 20,0005.86 | 16,7004.89 | 88% | 1.89 | Yes | 2 |
| ACIQ-018W-BL-MD (the pairing on screen) | ACIQ | 18,0005.28 | 18,0005.28 | 18,0005.28 | 100% | 2.00 | Yes | 1 |
| SCC-18-HH-MB (the pairing on screen) | ACIQ | 17,5005.13 | 20,0005.86 | 16,7004.89 | 88% | 1.89 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- ACIQ-18ZPL-HP230C 12 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- ACIQ-18ZPL-HP230C changed its certified heat output at 17°F on 2 pairings from 16,600 Btu/h to 18,000 Btu/h in the certified data between December 2025 and September 2026.
- ACIQ-18ZPL-HP230C changed its certified heat output at 17°F on 2 pairings from 15,000 Btu/h to 16,600 Btu/h in the certified data between March 2025 and May 2025.
- ACIQ-18ZPL-HP230C first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 4, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read