ODUMOX430-17HFN1MT0W
ODUMOX430-17HFN1MT0W is in the certified data.
Its certified full-speed heating output at 5°F is 16,000–18,000 Btu/h4.69–5.28 kW, 93–100% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Kepler · mini-split heat pump
ODUMOX430-17HFN1MT0W is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
19,0005.57NR
No 47°F rating for this pairing.
15,0004.40NR at 17°F
17,7005.19NR at 5°F
Btu/hkW, certified
1.85NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 19,000 Btu/h5.57 kW of heat at 47°F, 15,000 Btu/h4.40 kW at 17°F, and 17,700 Btu/h5.19 kW at 5°F, 93% of its 47°F rating. It delivers 17,000 Btu/h4.98 kW of cooling at 95°F. At 5°F that is 3,700 Btu/h1.08 kW above the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 10,000 Btu/h2.93 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214377769 · listed by Kepler · certified Apr 17, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 17,7005.19 kW | +25% | 1.85 | |
| 17°Ffull speed | 15,0004.40 kW | +1% | NR | |
| 47°Fnormal speed | 19,0005.57 kW | +6% | NR | |
| 95°Fcooling, full load | 17,0004.98 kW | — | NR |
EER2 11.7 in that test. SEER2 18.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.80kW
- Electrical input in the 95°F cooling test
- 1.45kW
- Seasonal average heating COP
- 2.78
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 17,700 Btu/h5.19 kWNR
- This unit at 5°F median across its pairings
- 17,700 Btu/h5.19 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 69% of them, at number 346 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- YN018GLSI25RPHPioneer · 17,800 Btu/h
- 2KARDA18SZO20Karda and PerfectAire · 17,700 Btu/h
- DIRM-18HXPRO28-1ZDirect Air · 17,700 Btu/h
- ACIQ-18ZPL-HP230C1HVAC and ACiQ · 17,500 Btu/h
- BMS500-AAS018-1CSXHDBosch · 17,500 Btu/h
- BZ33-HYP18OUT2-454-G3-PBreeze33 · 17,500 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for ODUMOX430-17HFN1MT0W
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 19,000 Btu/h5.57 kWNR | 17,000–19,000 Btu/h4.98–5.57 kW |
| Heat output at 17°F full speed | 15,000 Btu/h4.40 kWNR | 15,000–15,600 Btu/h4.40–4.57 kW |
| Heat output at 5°F full speed | 17,700 Btu/h5.19 kWNR | 16,000–18,000 Btu/h4.69–5.28 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 93%NR | |
| COP at 5°F full speed | 1.85NR | 1.75–1.85 |
| HSPF2 Region IV | 9.5NR | 9.5–11.3 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 17,000 Btu/h4.98 kWNR | 16,000–18,000 Btu/h4.69–5.28 kW |
| EER2 at 95°F | 11.7NR | 11.7–12.5 |
| SEER2 cooling season | 18.0NR | 18.0–21.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | IDUMTIU-18HWFN1-M | 3 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | ODUMOX430-17HFN1MT0W | |
Pairings, by indoor-unit class
3 indoor units · 3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 3 indoor units
-
IDUCCA3U-18HRFN1-M(C) (the pairing on screen) Kepler 16,000 Btu/h4.69 kWat 5°F, full speed
-
IDUMSEPC-18HRFN1MU0W (the pairing on screen) Kepler 18,000 Btu/h5.28 kWat 5°F, full speed
-
IDUMTIU-18HWFN1-M (the pairing on screen) Kepler 17,700 Btu/h5.19 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| IDUCCA3U-18HRFN1-M(C) (the pairing on screen) | Kepler | 16,0004.69 | 17,0004.98 | 16,0004.69 | 94% | 1.75 | Yes | 1 |
| IDUMSEPC-18HRFN1MU0W (the pairing on screen) | Kepler | 18,0005.28 | 18,0005.28 | 18,0005.28 | 100% | 1.80 | Yes | 1 |
| IDUMTIU-18HWFN1-M (the pairing on screen) | Kepler | 17,7005.19 | 19,0005.57 | 17,0004.98 | 93% | 1.85 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- ODUMOX430-17HFN1MT0W 3 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 17, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read