AOU36RLXFZH
AOU36RLXFZH is in the certified data.
Its certified full-speed heating output at 5°F is 36,400 Btu/h10.67 kW, 101% of its 47°F rating (tests at different compressor speeds) across its certified pairings.
Fujitsu · mini-split heat pump
AOU36RLXFZH is in the certified data as of Sep 19, 2026. AOU36RLXFZH changed its certified heat output at 47°F on 3 pairings from 36,400 Btu/h to 36,000 Btu/h in the certified data between March 2025 and May 2025.
- 36,000 Btu (3-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
36,00010.55NR
No 47°F rating for this pairing.
21,4006.27NR at 17°F
36,40010.67NR at 5°F
Btu/hkW, certified
2.02NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 36,000 Btu/h10.55 kW of heat at 47°F, 21,400 Btu/h6.27 kW at 17°F, and 36,400 Btu/h10.67 kW at 5°F, 101% of its 47°F rating. It delivers 35,200 Btu/h10.32 kW of cooling at 95°F. At 5°F that is 5,400 Btu/h1.58 kW above the example heating load of 31,000 Btu/h9.09 kW; at 95°F it is 19,700 Btu/h5.77 kW above the example cooling load of 15,500 Btu/h4.54 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,300 sq ft where winters reach 5°F: heating runs from 31,000 Btu/h9.09 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 15,500 Btu/h4.54 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 8908616 · listed by Fujitsu · certified Jun 5, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 36,40010.67 kW | +17% | 2.02 | |
| 17°Ffull speed | 21,4006.27 kW | −28% | NR | |
| 47°Fnormal speed | 36,00010.55 kW | −3% | NR | |
| 95°Fcooling, full load | 35,20010.32 kW | — | NR |
EER2 12.0 in that test. SEER2 18.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.28kW
- Electrical input in the 95°F cooling test
- 2.93kW
- Seasonal average heating COP
- 2.55
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton mini-split models
- This pairing at 5°F
- 36,400 Btu/h10.67 kWNR
- This unit at 5°F median across its pairings
- 36,400 Btu/h10.67 kW
- Median of 3-ton mini-split models at 5°F
- 31,000 Btu/h9.09 kW
- Models in this group
- 553
This unit is above 78% of them, at number 124 of 553 by heat at 5°F. The middle half of the group runs 26,000 to 36,000 Btu/h.
Closest models by heat at 5°F
- ACIQ-36ZPL-HP230B1HVAC, ACiQ + 3 more · 36,600 Btu/h
- MLB036S4S-2PLennox · 36,600 Btu/h
- A-VMH36QV-1ACentury and Comfort-Aire · 36,400 Btu/h
- AOUH36KWAH4Fujitsu · 36,400 Btu/h
- AOU-36U3T25UHisense · 36,000 Btu/h
- AUW-36U3TW1(JCH)Hisense · 36,000 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for AOU36RLXFZH
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 36,000 Btu/h10.55 kWNR | 36,000 Btu/h10.55 kW |
| Heat output at 17°F full speed | 21,400 Btu/h6.27 kWNR | 21,400 Btu/h6.27 kW |
| Heat output at 5°F full speed | 36,400 Btu/h10.67 kWNR | 36,400 Btu/h10.67 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 101%NR | |
| COP at 5°F full speed | 2.02NR | 2.02 |
| HSPF2 Region IV | 8.7NR | 8.7–9.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 35,200 Btu/h10.32 kWNR | 35,200 Btu/h10.32 kW |
| EER2 at 95°F | 12.0NR | 12.0–13.0 |
| SEER2 cooling season | 18.0NR | 18.0–20.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | AOU36RLXFZH | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) FUJITSU 36,400 Btu/h10.67 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | FUJITSU | 36,40010.67 | 36,00010.55 | 35,20010.32 | 101% | 2.02 | Yes | 3 |
Sold as, and units with identical certified values
New York program projects, 2017–2019
The AOU36RLXFZH is the outdoor unit in 59 projects of a New York State heat pump program, approved between Aug 25, 2017 and Dec 13, 2019.
| Projects | Median | Middle half | |
|---|---|---|---|
| Whole-project cost | 59 | $11,500 | $7,963–$15,655 |
| Cost after reported incentive | 59 | $10,705 | $7,198–$14,513 |
Each cost covers the whole project, installation included. A project can include several indoor units, or more than one outdoor unit of this model.
The median is the middle project's cost. The middle half runs from the 25th to the 75th percentile.
Cost after reported incentive is the project cost minus the incentive the program reported. It is a comparison figure, not a homeowner's bill: the incentive could have gone to the installer or to the property owner.
Dollars are as recorded at approval, 2017–2019, and are not adjusted for inflation. The projects name this outdoor unit. Their indoor units may differ from the pairings certified above.
Project records as of Oct 17, 2026.
What affects the price
We don't have current prices or quotes. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- AOU36RLXFZH changed its certified heat output at 47°F on 3 pairings from 36,400 Btu/h to 36,000 Btu/h in the certified data between March 2025 and May 2025.
- AOU36RLXFZH was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 5, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read