Heat Pump List

Tools

AOUH30LUAH1

AOUH30LUAH1 is in the certified data.

Its certified full-speed heating output at 5°F is 33,000 Btu/h, 110% of its 47°F rating (tests at different compressor speeds) across its certified pairings.

Fujitsu · mini-split heat pump

All 130 certified Fujitsu models

AOUH30LUAH1 is in the certified data as of Sep 19, 2026. AOUH30LUAH1 changed its certified heat output at 47°F on 3 pairings from 32,000 Btu/h to 30,000 Btu/h in the certified data between March 2025 and May 2025.

3 certified pairings with 3 different figures. See all

Certified heating and cooling

Heating at 47°F

30,000

19,600 at 17°F

33,000 at 5°F

Btu/h, certified

1.76 COP at 5°F

Cooling at 95°F

28,600

Btu/h, certified

EER2 13.5 at 95°F

SEER2 22.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for AOUH30LUAH1, by outdoor temperature Heating: 33,000 Btu/h at 5°F, 19,600 Btu/h at 17°F, 30,000 Btu/h at 47°F. Cooling: 28,600 Btu/h at 95°F. The bars start at zero. Median of 2.5-ton mini-split models: 25,000 Btu/h at 5°F, 25,600 Btu/h at 17°F, 30,000 Btu/h at 47°F, 30,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 33,000 5°F 19,600 17°F 30,000 47°F 28,600 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2.5-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 30,000 Btu/h of heat at 47°F, 19,600 Btu/h at 17°F, and 33,000 Btu/h at 5°F, 110% of its 47°F rating. It delivers 28,600 Btu/h of cooling at 95°F. At 5°F that is 8,000 Btu/h above the example heating load of 25,000 Btu/h; at 95°F it is 16,100 Btu/h above the example cooling load of 12,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,050 sq ft where winters reach 5°F: heating runs from 25,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 12,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 207657379 · listed by Fujitsu · certified Jun 5, 2026 · 1 pairing carries these values

Rebates where you live

Meets the recorded equipment thresholds of 52 programs in 30 states, provinces, or territories:Alabama (1), Arizona (1), California (2), Colorado (2), Connecticut (1), Delaware (2), Idaho (2), Illinois (1), Kentucky (1), Maine (2), Maryland (3), Massachusetts (1), Michigan (2), Minnesota (2), Mississippi (2), Nevada (1), New Hampshire (2), New Jersey (7), New York (4), Oregon (2), Pennsylvania (4), Rhode Island (1), Tennessee (1), Texas (2), Utah (1), Vermont (3), Washington (2), Wisconsin (1), British Columbia (3), Newfoundland and Labrador (1).

All 52 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Delaware

Idaho

Illinois

Kentucky

Maine

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

Oregon

Pennsylvania

Rhode Island

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Newfoundland and Labrador

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2.5-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 33,0009.67 kW +32% 1.76
17°Ffull speed 19,6005.74 kW −23% NR
47°Fnormal speed 30,0008.79 kW 0% NR
95°Fcooling, full load 28,6008.38 kW — NR

EER2 13.5 in that test. SEER2 22.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
5.50kW
Electrical input in the 95°F cooling test
2.12kW
Seasonal average heating COP
3.22

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 30,000 Btu heat pumps

2.5-ton mini-split models

This pairing at 5°F
33,000 Btu/h
This unit at 5°F median across its pairings
33,000 Btu/h
Median of 2.5-ton mini-split models at 5°F
25,000 Btu/h
Models in this group
405

This unit is above 83% of them, at number 67 of 405 by heat at 5°F. The middle half of the group runs 20,000 to 27,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 30,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 18th of 405; HSPF2, 55th of 405 (tied). Models without that figure are left out.

Similar ratings at 47°F

These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • AOD30-30HFN1-MS0W: The same 30,000 Btu/h rating at 47°F; 17,500 Btu/h at 5°F (this model: 33,000).
  • ADSZ130DA: The same 30,000 Btu/h rating at 47°F; 18,000 Btu/h at 5°F (this model: 33,000).
  • MOD-30HFN1CA: The same 30,000 Btu/h rating at 47°F; 18,400 Btu/h at 5°F (this model: 33,000).

Closest models by heat at 5°F

Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 33,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42790–1,380
MildTypical16–261,270–2,060
MildTight, well insulated10–181,830–3,300
ColdDrafty, little insulation28–52630–1,180
ColdTypical18–301,100–1,830
ColdTight, well insulated12–221,500–2,750
Very coldDrafty, little insulation32–58570–1,030
Very coldTypical22–38870–1,500
Very coldTight, well insulated16–281,180–2,060

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for AOUH30LUAH1

3 pairings · 3 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for AOUH30LUAH1
This pairingAll pairings
Heating
Heat output at 47°F normal speed 30,000 Btu/h 30,000 Btu/h
Heat output at 17°F full speed 19,600 Btu/h 19,600–21,600 Btu/h
Heat output at 5°F full speed 33,000 Btu/h 33,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 110%
COP at 5°F full speed 1.76 1.76
HSPF2 Region IV 11.0 9.7–11.0
Cooling
Cooling capacity at 95°F full-load test 28,600 Btu/h 28,600 Btu/h
EER2 at 95°F 13.5 11.7–13.5
SEER2 cooling season 22.0 18.3–22.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit AUUH30LUAS 3 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified AOUH30LUAH1

Across 3 certified pairings with 3 indoor models: heat at 5°F 33,000 Btu/h throughout; HSPF2 9.7 with AMUG30LMAS to 11.0 with AUUH30LUAS; SEER2 18.3 with ARUH30LUAS to 22.0 with AUUH30LUAS. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

3 indoor units · 3 certified pairings

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 3 indoor units

  1. AMUG30LMAS FUJITSU 33,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 30,000 Btu/h · 95°F cooling 28,600 Btu/h · Cold output 110% · COP 1.76

  2. ARUH30LUAS FUJITSU 33,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 30,000 Btu/h · 95°F cooling 28,600 Btu/h · Cold output 110% · COP 1.76

  3. AUUH30LUAS (the pairing on screen) FUJITSU 33,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 30,000 Btu/h · 95°F cooling 28,600 Btu/h · Cold output 110% · COP 1.76

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
AMUG30LMAS FUJITSU 33,000 30,000 28,600 110% 1.76 Yes 1
ARUH30LUAS FUJITSU 33,000 30,000 28,600 110% 1.76 Yes 1
AUUH30LUAS (the pairing on screen) FUJITSU 33,000 30,000 28,600 110% 1.76 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 3 of 3 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Product history

  • AOUH30LUAH1 changed its certified heat output at 47°F on 3 pairings from 32,000 Btu/h to 30,000 Btu/h in the certified data between March 2025 and May 2025.
  • AOUH30LUAH1 was in the certified data by September 2024.

History and definitions

Other H-Series models by nominal cooling size: AOU9RLFF (9,000 Btu), AOU9RLFFH (9,000 Btu), AOUG09LZAH1 (9,000 Btu), AOUG09LZAS1 (9,000 Btu), AOUH09LEAS1 (9,000 Btu), AOUH09LMAH1 (9,000 Btu), AOUH09LMAS1 (9,000 Btu), AOUH09LPAS1 (9,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Jun 5, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “AOUH30LUAH1 — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/aouh30luah1