Heat Pump List

Tools

AR12CSFCMWKX

AR12CSFCMWKX is in the certified data.

Its certified full-speed heating output at 5°F is 9,900 Btu/h, 83% of its 47°F rating (tests at different compressor speeds) in its certified pairing.

Samsung · mini-split heat pump

All 76 certified Samsung models

AR12CSFCMWKX is in the certified data as of Sep 19, 2026.

Certified heating and cooling

Heating at 47°F

12,000

11,000 at 17°F

9,900 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

12,000

Btu/h, certified

EER2 12.0 at 95°F

SEER2 20.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for AR12CSFCMWKX, by outdoor temperature Heating: 9,900 Btu/h at 5°F, 11,000 Btu/h at 17°F, 12,000 Btu/h at 47°F. Cooling: 12,000 Btu/h at 95°F. The bars start at zero. Median of 1-ton mini-split models: 9,200 Btu/h at 5°F, 9,800 Btu/h at 17°F, 12,000 Btu/h at 47°F, 12,000 Btu/h at 95°F. 0 2,500 5,000 7,500 10,000 12,500 Btu/h 9,900 5°F 11,000 17°F 12,000 47°F 12,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 1-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 12,000 Btu/h of heat at 47°F, 11,000 Btu/h at 17°F, and 9,900 Btu/h at 5°F, 83% of its 47°F rating. It delivers 12,000 Btu/h of cooling at 95°F. At 5°F that is 900 Btu/h above the example heating load of 9,000 Btu/h; at 95°F it is 7,000 Btu/h above the example cooling load of 5,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 400 sq ft where winters reach 5°F: heating runs from 9,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 210448841 · listed by Samsung · certified Mar 5, 2025 · 1 pairing carries these values

Rebates where you live

Meets the recorded equipment thresholds of 28 programs in 18 states, provinces, or territories:Alabama (1), Arizona (1), California (2), Colorado (1), Delaware (2), Idaho (2), Kentucky (1), Maryland (3), Michigan (2), Mississippi (2), New Jersey (4), Oregon (2), Pennsylvania (4), Tennessee (1), Texas (2), Utah (1), Washington (1), Wisconsin (1).

All 28 programs by state and province

Alabama

Arizona

California

Colorado

Delaware

Idaho

Kentucky

Maryland

Michigan

Mississippi

New Jersey

Oregon

Pennsylvania

Tennessee

Texas

Utah

Washington

Wisconsin

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 1-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 9,9002.90 kW +8% 2.00
17°Ffull speed 11,0003.22 kW +12% NR
47°Fnormal speed 12,0003.52 kW 0% NR
95°Fcooling, full load 12,0003.52 kW — NR

EER2 12.0 in that test. SEER2 20.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.45kW
Electrical input in the 95°F cooling test
1.00kW
Seasonal average heating COP
2.43

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 12,000 Btu heat pumps

1-ton mini-split models

This pairing at 5°F
9,900 Btu/h
This unit at 5°F median across its pairings
9,900 Btu/h
Median of 1-ton mini-split models at 5°F
9,200 Btu/h
Models in this group
888

This unit is above 59% of them, at number 360 of 888 by heat at 5°F. The middle half of the group runs 8,400 to 11,300 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 12,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 330th of 887; HSPF2, 890th of 895. Models without that figure are left out.

Similar ratings at 47°F

These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • BM12YDIY22C: The same 12,000 Btu/h rating at 47°F; 46,000 Btu/h at 5°F (this model: 9,900).
  • MSH123G26MCAA: The same 12,000 Btu/h rating at 47°F; 13,500 Btu/h at 5°F (this model: 9,900).
  • AOUG12LZAH1: The same 12,000 Btu/h rating at 47°F; 16,600 Btu/h at 5°F (this model: 9,900).

Closest models by heat at 5°F

Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 9,900 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42240–410
MildTypical16–26380–620
MildTight, well insulated10–18550–990
ColdDrafty, little insulation28–52190–350
ColdTypical18–30330–550
ColdTight, well insulated12–22450–830
Very coldDrafty, little insulation32–58170–310
Very coldTypical22–38260–450
Very coldTight, well insulated16–28350–620

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for AR12CSFCMWKX

1 pairing · 1 AHRI certificate

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for AR12CSFCMWKX
This pairingAll pairings
Heating
Heat output at 47°F normal speed 12,000 Btu/h 12,000 Btu/h
Heat output at 17°F full speed 11,000 Btu/h 11,000 Btu/h
Heat output at 5°F full speed 9,900 Btu/h 9,900 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 83%
COP at 5°F full speed 2.00 2.00
HSPF2 Region IV 8.3 8.3
Cooling
Cooling capacity at 95°F full-load test 12,000 Btu/h 12,000 Btu/h
EER2 at 95°F 12.0 12.0
SEER2 cooling season 20.0 20.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit AR12CSFCMWKN 1 indoor unit
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold United States United States
Model string as certified AR12CSFCMWKX

Pairings, by indoor-unit class

1 indoor unit · 1 certified pairing

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 1 indoor unit

  1. AR12CSFCMWKN (the pairing on screen) SAMSUNG 9,900 Btu/hat 5°F, full speed

    1 pairing · 47°F 12,000 Btu/h · 95°F cooling 12,000 Btu/h · Cold output 83% · COP 2.00

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
AR12CSFCMWKN (the pairing on screen) SAMSUNG 9,900 12,000 12,000 83% 2.00 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 1 of 1 indoor unit

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Mar 5, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “AR12CSFCMWKX — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/ar12csfcmwkx