ASH4248UCDD
ASH4248UCDD is in the certified data.
Its certified full-speed heating output at 5°F is 32,800–36,800 Btu/h9.61–10.79 kW, 74–82% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
GE · mini-split heat pump
ASH4248UCDD is in the certified data as of Sep 19, 2026. ASH4248UCDD changed its certified heat output at 47°F on AHRI certificate 211744614 from 42,000 Btu/h to 44,000 Btu/h in the certified data between August 2025 and September 2026.
- 42,000 Btu (3.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
48,00014.07NR
No 47°F rating for this pairing.
34,60010.14NR at 17°F
35,60010.43NR at 5°F
Btu/hkW, certified
1.75NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 48,000 Btu/h14.07 kW of heat at 47°F, 34,600 Btu/h10.14 kW at 17°F, and 35,600 Btu/h10.43 kW at 5°F, 74% of its 47°F rating. It delivers 46,000 Btu/h13.48 kW of cooling at 95°F. At 5°F that is 400 Btu/h0.12 kW short of the example heating load of 36,000 Btu/h10.55 kW; at 95°F it is 28,000 Btu/h8.21 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,000 Btu/h10.55 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 211729714 · listed by GE Appliances · certified May 28, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 23 programs in 20 states, provinces, or territories:Alabama (1), Arizona (1), California (1), Connecticut (1), Idaho (2), Kentucky (1), Massachusetts (1), Minnesota (1), Mississippi (2), New Hampshire (1), New Jersey (2), New York (4), Oregon (2), Rhode Island (1), Tennessee (1), Vermont (3), Washington (1), Wisconsin (1), British Columbia (3), Newfoundland and Labrador (1).
All 23 programs by state and province
Alabama
Arizona
California
Connecticut
Idaho
Kentucky
Massachusetts
Minnesota
Mississippi
- EnergyRight Home Energy Rebates · TVA EnergyRight · EPB
- Entergy Mississippi Residential Heating and Cooling
New Hampshire
New Jersey
New York
- EmPower+
- NYS Clean Heat: Central Hudson, NYSEG, RG&E, and O&R · Orange & Rockland
- NYS Clean Heat: Con Edison
- NYS Clean Heat: National Grid
Oregon
- Energy Trust of Oregon Heat Pump Incentives · Portland General Electric (PGE) · Pacific Power
- Idaho Power Heating and Cooling Efficiency Program
Rhode Island
Tennessee
Vermont
- Burlington Electric Heat Pump Rebates · Burlington Electric Department
- Efficiency Vermont Heat Pump Discounts
- Green Mountain Power Income-Eligible Heat Pump Rebate
Washington
Wisconsin
British Columbia
- CleanBC Energy Savings Program · BC Hydro · FortisBC · municipal utilities
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Newfoundland and Labrador
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 35,60010.43 kW | −1% | 1.75 | |
| 17°Ffull speed | 34,60010.14 kW | +8% | NR | |
| 47°Fnormal speed | 48,00014.07 kW | +9% | NR | |
| 95°Fcooling, full load | 46,00013.48 kW | — | NR |
EER2 7.3 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.96kW
- Electrical input in the 95°F cooling test
- 6.30kW
- Seasonal average heating COP
- 2.58
These exclude backup resistance heat.
How it compares with other 42,000 Btu heat pumps
3.5-ton mini-split models
- This pairing at 5°F
- 35,600 Btu/h10.43 kWNR
- This unit at 5°F median across its pairings
- 35,600 Btu/h10.43 kW
- Median of 3.5-ton mini-split models at 5°F
- 36,000 Btu/h10.55 kW
- Models in this group
- 161
This unit is above 40% of them, at number 96 of 161 by heat at 5°F. The middle half of the group runs 33,000 to 37,000 Btu/h.
Among 42,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 123rd of 161 (tied); HSPF2, 148th of 161 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- PUZ-AK42NL2: The same 45,000 Btu/h rating at 47°F; 25,400 Btu/h at 5°F (this model: 35,600).
- YRAMG42N5HAA: The same 45,000 Btu/h rating at 47°F; 29,400 Btu/h at 5°F (this model: 35,600).
- 1G4248ED2BE: The same 45,000 Btu/h rating at 47°F; HSPF2 10.0 (this model: 8.7).
Closest models by heat at 5°F
- ZE-42M522SCOZephyr · 36,000 Btu/h
- AOUH45KWAS5Fujitsu · 35,800 Btu/h
- AOUH45KWBS5Fujitsu · 35,800 Btu/h
- 5G42ED2BEGE · 35,000 Btu/h
- FPHMR42A3DFriedrich, Rheem + 1 more · 35,000 Btu/h
- UMC48CN23STG1Coleman, Guardian + 1 more · 35,000 Btu/h
Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 35,600 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 850–1,480 |
| Mild | Typical | 16–26 | 1,370–2,230 |
| Mild | Tight, well insulated | 10–18 | 1,980–3,560 |
| Cold | Drafty, little insulation | 28–52 | 680–1,270 |
| Cold | Typical | 18–30 | 1,190–1,980 |
| Cold | Tight, well insulated | 12–22 | 1,620–2,970 |
| Very cold | Drafty, little insulation | 32–58 | 610–1,110 |
| Very cold | Typical | 22–38 | 940–1,620 |
| Very cold | Tight, well insulated | 16–28 | 1,270–2,230 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for ASH4248UCDD
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 48,000 Btu/h14.07 kWNR | 44,000–48,000 Btu/h12.90–14.07 kW |
| Heat output at 17°F full speed | 34,600 Btu/h10.14 kWNR | 31,000–34,600 Btu/h9.09–10.14 kW |
| Heat output at 5°F full speed | 35,600 Btu/h10.43 kWNR | 32,800–36,800 Btu/h9.61–10.79 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 74%NR | |
| COP at 5°F full speed | 1.75NR | 1.75 |
| HSPF2 Region IV | 8.8NR | 8.5–8.8 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 46,000 Btu/h13.48 kWNR | 42,000–46,000 Btu/h12.31–13.48 kW |
| EER2 at 95°F | 7.3NR | 7.3–8.7 |
| SEER2 cooling season | 15.2NR | 15.2–18.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | USYM48UCDD** | 3 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | ASH4248UCDD** | |
Across 3 certified pairings with 3 indoor models: heat at 5°F 32,800 Btu/h with USYL42UCDD** to 36,800 Btu/h with USYM42UCDD**; HSPF2 8.5 with USYL42UCDD** to 8.8 with USYM48UCDD**; SEER2 15.2 with USYM42UCDD** to 18.0 with USYL42UCDD**. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.
Pairings, by indoor-unit class
3 indoor units · 3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 3 indoor units
-
USYL42UCDD** (the pairing on screen) GE Appliances 32,800 Btu/h9.61 kWat 5°F, full speed
-
USYM42UCDD** (the pairing on screen) GE Appliances 36,800 Btu/h10.79 kWat 5°F, full speed
-
USYM48UCDD** (the pairing on screen) GE Appliances 35,600 Btu/h10.43 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| USYL42UCDD** (the pairing on screen) | GE Appliances | 32,8009.61 | 44,00012.90 | 42,00012.31 | 75% | 1.75 | Yes | 1 |
| USYM42UCDD** (the pairing on screen) | GE Appliances | 36,80010.79 | 45,00013.19 | 42,00012.31 | 82% | 1.75 | Yes | 1 |
| USYM48UCDD** (the pairing on screen) | GE Appliances | 35,60010.43 | 48,00014.07 | 46,00013.48 | 74% | 1.75 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- ASH4248UCDD changed its certified heat output at 47°F on AHRI certificate 211744614 from 42,000 Btu/h to 44,000 Btu/h in the certified data between August 2025 and September 2026.
- ASH4248UCDD changed its certified heat output at 47°F on AHRI certificate 211744614 from 44,000 Btu/h to 42,000 Btu/h in the certified data between March 2025 and May 2025.
- ASH4248UCDD was in the certified data by September 2024.
History and definitions
Other Endure PRO models by nominal cooling size: 1G24ED2BE (24,000 Btu), 1G3036ED2BE (30,000 Btu), ASH3036UCDD (30,000 Btu), 1G4248ED2BE (42,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- May 28, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read