AWK09*3*2
Ephoca and Innova · central heat pump
AWK09*3*2 is in the certified data as of Sep 19, 2026.
Certified heating and cooling
Heating at 47°F
6,7001.96NR
No 47°F rating for this pairing.
4,8001.41NR at 17°F
4,5001.32NR at 5°F
Btu/hkW, certified
1.77NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 6,700 Btu/h1.96 kW of heat at 47°F, 4,800 Btu/h1.41 kW at 17°F, and 4,500 Btu/h1.32 kW at 5°F, 67% of its 47°F rating. It delivers 6,700 Btu/h1.96 kW of cooling at 95°F. At 5°F that is 1,500 Btu/h0.44 kW short of the example heating load of 6,000 Btu/h1.76 kW; at 95°F it is 3,700 Btu/h1.08 kW above the example cooling load of 3,000 Btu/h0.88 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 6,000 Btu central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 250 sq ft where winters reach 5°F: heating runs from 6,000 Btu/h1.76 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,000 Btu/h0.88 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217677979 · listed by Ephoca · certified Jan 20, 2026 · 2 pairings on 2 certificates share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 4,5001.32 kW | −24% | 1.77 | |
| 17°Ffull speed | 4,8001.41 kW | −38% | NR | |
| 47°Fnormal speed | 6,7001.96 kW | −18% | NR | |
| 95°Fcooling, full load | 6,7001.96 kW | — | NR |
EER2 10.45 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 0.75kW
- Electrical input in the 95°F cooling test
- 0.64kW
- Seasonal average heating COP
- 2.51
These exclude backup resistance heat.
How it compares with other 6,000 Btu heat pumps
6,000 Btu central models
- This pairing at 5°F
- 4,500 Btu/h1.32 kWNR
- This unit at 5°F median across its pairings
- 4,500 Btu/h1.32 kW
- Median of 6,000 Btu central models at 5°F
- 5,900 Btu/h1.73 kW
- Models in this group
- 134
This unit is above 0% of them, at number 134 of 134 by heat at 5°F. The middle half of the group runs 4,500 to 5,900 Btu/h.
Closest models by heat at 5°F
Every 6,000 Btu unit, ranked by cooling efficiency, then heating efficiency
Certified values for AWK09*3*2
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 6,700 Btu/h1.96 kWNR | 6,700 Btu/h1.96 kW |
| Heat output at 17°F full speed | 4,800 Btu/h1.41 kWNR | 4,800 Btu/h1.41 kW |
| Heat output at 5°F full speed | 4,500 Btu/h1.32 kWNR | 4,500 Btu/h1.32 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 67%NR | |
| COP at 5°F full speed | 1.77NR | 1.77 |
| HSPF2 Region IV | 8.6NR | 8.6 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 6,700 Btu/h1.96 kWNR | 6,700 Btu/h1.96 kW |
| EER2 at 95°F | 10.45NR | 10.45 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | AWK09*3*2 | |
Pairings, by indoor-unit class
2 certified pairings
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated 4,500 Btu/h1.32 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | 4,5001.32 | 6,7001.96 | 6,7001.96 | 67% | 1.77 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- AWK09*3*2 2 pairings
Variants of the same model number
40 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFE09N3H1Ephoca · Innova
- AFE09N3H2Ephoca · Innova
- AFE09R3H1Ephoca · Innova
- AFE09R3H2Ephoca · Innova
- AFK09N3H1Ephoca · Innova
- AFK09N3H2Ephoca · Innova
- AFK09R3H1Ephoca · Innova
- AFK09R3H2Ephoca · Innova
- AFP09N3H1Ephoca · Innova
- AFP09N3H2Ephoca · Innova
- AFP09R3H1Ephoca · Innova
- AFP09R3H2Ephoca · Innova
- AWE09*3*2Ephoca · Innova
- AWE09*4*2Ephoca · Innova
- AWE09N3H1-3Ephoca · Innova
- AWE09N3H1-3SPEphoca · Innova
- AWE09N3H2Ephoca · Innova
- AWE09N3H2-3Ephoca · Innova
- AWE09N3H2-3SPEphoca · Innova
- AWE09R3H2Ephoca · Innova
- AWK09*4*2Ephoca · Innova
- AWK09N3H1-3Ephoca · Innova
- AWK09N3H1-3SPEphoca · Innova
- AWK09N3H2Ephoca · Innova
- AWK09N3H2-3Ephoca · Innova
- AWK09N3H2-3SPEphoca · Innova
- AWK09R3H2Ephoca · Innova
- AWP09*3*1Ephoca · Innova
- AWP09*3*2Ephoca · Innova
- AWP09*4*1Ephoca · Innova
- AWP09*4*2Ephoca · Innova
- AWP09N3H1Ephoca · Innova
- AWP09N3H1-3Ephoca · Innova
- AWP09N3H1-3SPEphoca · Innova
- AWP09N3H2Ephoca · Innova
- AWP09N3H2-3Ephoca · Innova
- AWP09N3H2-3SPEphoca · Innova
- AWP09R3H1Ephoca · Innova
- AWP09R3H2Ephoca · Innova
39 of 40 shown.
Other model numbers with identical certified values
40 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFE09N3H1identical certified values
- AFE09N3H2identical certified values
- AFE09R3H1identical certified values
- AFE09R3H2identical certified values
- AFK09N3H1identical certified values
- AFK09N3H2identical certified values
- AFK09R3H1identical certified values
- AFK09R3H2identical certified values
- AFP09N3H1identical certified values
- AFP09N3H2identical certified values
- AFP09R3H1identical certified values
- AFP09R3H2identical certified values
- AWE09*3*2identical certified values
- AWE09*4*2identical certified values
- AWE09N3H1-3identical certified values
- AWE09N3H1-3SPidentical certified values
- AWE09N3H2identical certified values
- AWE09N3H2-3identical certified values
- AWE09N3H2-3SPidentical certified values
- AWE09R3H2identical certified values
- AWK09*4*2identical certified values
- AWK09N3H1-3identical certified values
- AWK09N3H1-3SPidentical certified values
- AWK09N3H2identical certified values
- AWK09N3H2-3identical certified values
- AWK09N3H2-3SPidentical certified values
- AWK09R3H2identical certified values
- AWP09*3*1identical certified values
- AWP09*3*2identical certified values
- AWP09*4*1identical certified values
- AWP09*4*2identical certified values
- AWP09N3H1identical certified values
- AWP09N3H1-3identical certified values
- AWP09N3H1-3SPidentical certified values
- AWP09N3H2identical certified values
- AWP09N3H2-3identical certified values
- AWP09N3H2-3SPidentical certified values
- AWP09R3H1identical certified values
- AWP09R3H2identical certified values
39 of 40 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jan 20, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read