B5H3V48*K*AAA*

B5H3V48*K*AAA* is in the certified data.

Its certified full-speed heating output at 5°F is 35,600–37,400 Btu/h, 74–77% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

ACiQ, Airquest + 7 more · central heat pump

B5H3V48*K*AAA* is in the certified data as of Sep 19, 2026.

648 certified pairings with 42 different figures. See all

Certified heating and cooling

Heating at 47°F

48,000

39,500 at 17°F

36,600 at 5°F

Btu/h, certified

1.88 COP at 5°F

Cooling at 95°F

43,500

Btu/h, certified

EER2 10.5 at 95°F

SEER2 20.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for B5H3V48*K*AAA*, by outdoor temperature Heating: 36,600 Btu/h at 5°F, 39,500 Btu/h at 17°F, 48,000 Btu/h at 47°F. Cooling: 43,500 Btu/h at 95°F. The bars start at zero. Median of 3.5-ton central models: 33,000 Btu/h at 5°F, 31,000 Btu/h at 17°F, 44,000 Btu/h at 47°F, 44,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 50,000 Btu/h 36,600 5°F 39,500 17°F 48,000 47°F 43,500 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 48,000 Btu/h of heat at 47°F, 39,500 Btu/h at 17°F, and 36,600 Btu/h at 5°F, 76% of its 47°F rating. It delivers 43,500 Btu/h of cooling at 95°F. At 5°F that is 3,600 Btu/h above the example heating load of 33,000 Btu/h; at 95°F it is 26,500 Btu/h above the example cooling load of 17,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,400 sq ft where winters reach 5°F: heating runs from 33,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 17,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 218413200 · listed by Heil · certified May 12, 2026 · 36 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 36,60010.73 kW +11% 1.88
17°Ffull speed 39,50011.58 kW +27% NR
47°Fnormal speed 48,00014.07 kW +9% NR
95°Fcooling, full load 43,50012.75 kW — NR

EER2 10.5 in that test. SEER2 20.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
5.71kW
Electrical input in the 95°F cooling test
4.14kW
Seasonal average heating COP
2.64

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 42,000 Btu heat pumps

3.5-ton central models

This pairing at 5°F
36,600 Btu/h
This unit at 5°F median across its pairings
36,600 Btu/h
Median of 3.5-ton central models at 5°F
33,000 Btu/h
Models in this group
222

This unit is above 59% of them, at number 90 of 222 by heat at 5°F. The middle half of the group runs 20,000 to 40,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for B5H3V48*K*AAA*

648 pairings · 648 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for B5H3V48*K*AAA*
This pairingAll pairings
Heating
Heat output at 47°F normal speed 48,000 Btu/h 48,000–49,000 Btu/h
Heat output at 17°F full speed 39,500 Btu/h 39,000–40,500 Btu/h
Heat output at 5°F full speed 36,600 Btu/h 35,600–37,400 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 76%
COP at 5°F full speed 1.88 1.84–2.00
HSPF2 Region IV 9.0 9.0–9.5
Cooling
Cooling capacity at 95°F full-load test 43,500 Btu/h 43,000–46,500 Btu/h
EER2 at 95°F 10.5 10.0–12.5
SEER2 cooling season 20.5 20.0–23.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit EA*5X48M21A*+WALLCON 8 indoor units
Furnace*80CTL0702120B* 18 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified B5H3V48*K*AAA*

Pairings, by indoor-unit class

8 indoor units · 648 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 6 indoor units

  1. EA*5X61M24A*+WALLCON brand not stated 36,800 Btu/hat 5°F, full speed

    144 pairings, 16 with a furnace · 47°F 48,500 Btu/h · 95°F cooling 45,500 Btu/h · Cold output 76% · COP 1.88

  2. EA*5X61M21A*+WALLCON brand not stated 36,900 Btu/hat 5°F, full speed

    126 pairings, 14 with a furnace · 47°F 48,500 Btu/h · 95°F cooling 45,250 Btu/h · Cold output 76% · COP 1.86

  3. ESH5X48M12A*+WALLCON brand not stated 36,400 Btu/hat 5°F, full speed

    126 pairings, 14 with a furnace · 47°F 48,500 Btu/h · 95°F cooling 44,000 Btu/h · Cold output 75% · COP 1.88

  4. EA*5X48M21A*+WALLCON (the pairing on screen) brand not stated 36,600 Btu/hat 5°F, full speed

    108 pairings, 12 with a furnace · 47°F 48,000 Btu/h · 95°F cooling 43,500 Btu/h · Cold output 76% · COP 1.88

  5. EA*5X60M24A*+WALLCON brand not stated 36,500 Btu/hat 5°F, full speed

    72 pairings, 8 with a furnace · 47°F 48,250 Btu/h · 95°F cooling 44,500 Btu/h · Cold output 75% · COP 1.89

  6. ESH5X60M12A*+WALLCON brand not stated 36,600 Btu/hat 5°F, full speed

    54 pairings, 6 with a furnace · 47°F 48,500 Btu/h · 95°F cooling 45,000 Btu/h · Cold output 75% · COP 1.88

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
EA*5X61M24A*+WALLCON — 36,800 48,500 45,500 76% 1.88 Yes 144
EA*5X61M21A*+WALLCON — 36,900 48,500 45,250 76% 1.86 Yes 126
ESH5X48M12A*+WALLCON — 36,400 48,500 44,000 75% 1.88 Yes 126
EA*5X48M21A*+WALLCON (the pairing on screen) — 36,600 48,000 43,500 76% 1.88 Yes 108
EA*5X60M24A*+WALLCON — 36,500 48,250 44,500 75% 1.89 Yes 72
ESH5X60M12A*+WALLCON — 36,600 48,500 45,000 75% 1.88 Yes 54

Air handler · 2 indoor units

  1. FCMA5B48L0C*+WALLCON brand not stated 36,000 Btu/hat 5°F, full speed

    9 pairings · 47°F 48,500 Btu/h · 95°F cooling 45,500 Btu/h · Cold output 74% · COP 2.00

  2. FCMA5B60L0D*+WALLCON brand not stated 35,600 Btu/hat 5°F, full speed

    9 pairings · 47°F 48,000 Btu/h · 95°F cooling 46,500 Btu/h · Cold output 74% · COP 1.98

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
FCMA5B48L0C*+WALLCON — 36,000 48,500 45,500 74% 2.00 Yes 9
FCMA5B60L0D*+WALLCON — 35,600 48,000 46,500 74% 1.98 Yes 9

The share is heat output at 5°F divided by the 47°F rating.

Showing 8 of 8 indoor units All 648 certified pairings

Sold as, and units with identical certified values

History and definitions

History

First certified record
Most recent certified record
Measurements reported
May 12, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page