CENTRAL-24-HP-C-230A00
CENTRAL-24-HP-C-230A00 is in the certified data.
Its certified full-speed heating output at 5°F is 22,600 Btu/h6.62 kW, 94% of its 47°F rating (tests at different compressor speeds) in its certified pairing.
MRCOOL · central heat pump
CENTRAL-24-HP-C-230A00 is in the certified data as of Sep 19, 2026.
- 24,000 Btu (2-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
24,0007.03NR
No 47°F rating for this pairing.
19,2005.63NR at 17°F
22,6006.62NR at 5°F
Btu/hkW, certified
1.91NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 24,000 Btu/h7.03 kW of heat at 47°F, 19,200 Btu/h5.63 kW at 17°F, and 22,600 Btu/h6.62 kW at 5°F, 94% of its 47°F rating. It delivers 24,000 Btu/h7.03 kW of cooling at 95°F. At 5°F that is 3,600 Btu/h1.06 kW above the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 14,500 Btu/h4.25 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 211497151 · listed by MRCOOL · certified Jun 9, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 22,6006.62 kW | +19% | 1.91 | |
| 17°Ffull speed | 19,2005.63 kW | 0% | NR | |
| 47°Fnormal speed | 24,0007.03 kW | 0% | NR | |
| 95°Fcooling, full load | 24,0007.03 kW | — | NR |
EER2 11.7 in that test. SEER2 17.4 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.47kW
- Electrical input in the 95°F cooling test
- 2.05kW
- Seasonal average heating COP
- 2.93
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton central models
- This pairing at 5°F
- 22,600 Btu/h6.62 kWNR
- This unit at 5°F median across its pairings
- 22,600 Btu/h6.62 kW
- Median of 2-ton central models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 565
This unit is above 81% of them, at number 106 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.
Closest models by heat at 5°F
- MHD-24Dettson and Innovair · 23,000 Btu/h
- VUH24-VA6BA(O)Samyou and Vino · 22,800 Btu/h
- ACIQ-24-HPB1HVAC, ACiQ + 3 more · 22,600 Btu/h
- DLCURAH24ABKAirquest, Arcoaire + 13 more · 22,600 Btu/h
- MOD30-24HFN1-MWAlsetria, CanAir + 4 more · 22,600 Btu/h
- MOX430-24HFN8-M3MDV · 22,600 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for CENTRAL-24-HP-C-230A00
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 24,000 Btu/h7.03 kWNR | 24,000 Btu/h7.03 kW |
| Heat output at 17°F full speed | 19,200 Btu/h5.63 kWNR | 19,200 Btu/h5.63 kW |
| Heat output at 5°F full speed | 22,600 Btu/h6.62 kWNR | 22,600 Btu/h6.62 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 94%NR | |
| COP at 5°F full speed | 1.91NR | 1.91 |
| HSPF2 Region IV | 10.0NR | 10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 24,000 Btu/h7.03 kWNR | 24,000 Btu/h7.03 kW |
| EER2 at 95°F | 11.7NR | 11.7 |
| SEER2 cooling season | 17.4NR | 17.4 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | CENTRAL-24-HP-MUAH230A00 | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | CENTRAL-24-HP-C-230A00 | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Air handler · 1 indoor unit
-
CENTRAL-24-HP-MUAH230A00 (the pairing on screen) brand not stated 22,600 Btu/h6.62 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CENTRAL-24-HP-MUAH230A00 (the pairing on screen) | — | 22,6006.62 | 24,0007.03 | 24,0007.03 | 94% | 1.91 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- CENTRAL-24-HP-C-230A00 1 pairing
Variants of the same model number
10 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 3PAHHSD24-SZOPerfectAire
- AUO18-24N1-M3HAI Air Conditioning
- CNTM16DHP24AAConnect M
- EHI-O24BAHEco AC
- EZ-24-HP1HVAC · DIYCool · InfinityLiving · PolarWave
- MOD30-24HFN1-MW-[X1]MDV
- SENDC-24HF-OMSenville
- UHO24-NB-QMitsutomo
- WDLCURAH24ABKGrandaire
9 of 10 shown.
Other model numbers with identical certified values
9 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 3PAHHSD24-SZOidentical certified values
- AUO18-24N1-M3Hidentical certified values
- CNTM16DHP24AAidentical certified values
- EHI-O24BAHidentical certified values
- MOD30-24HFN1-MW-[X1]identical certified values
- SENDC-24HF-OMidentical certified values
- UHO24-NB-Qidentical certified values
- WDLCURAH24ABKidentical certified values
8 of 9 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 9, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read