Heat Pump List

Tools

CH-06OLVWM-115VO

CH-06OLVWM-115VO is in the certified data.

Its certified full-speed heating output at 5°F is 6,700 Btu/h, 96% of its 47°F rating (tests at different compressor speeds) across its certified pairings.

C&H and Cooper&Hunter · mini-split heat pump

All 36 certified C&H models · All 78 certified Cooper&Hunter models

CH-06OLVWM-115VO is in the certified data as of Sep 19, 2026.

Certified heating and cooling

Heating at 47°F

7,000

5,900 at 17°F

6,700 at 5°F

Btu/h, certified

2.06 COP at 5°F

Cooling at 95°F

6,000

Btu/h, certified

EER2 13.8 at 95°F

SEER2 23.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for CH-06OLVWM-115VO, by outdoor temperature Heating: 6,700 Btu/h at 5°F, 5,900 Btu/h at 17°F, 7,000 Btu/h at 47°F. Cooling: 6,000 Btu/h at 95°F. The bars start at zero. Median of 6,000 Btu mini-split models: 7,700 Btu/h at 5°F, 8,000 Btu/h at 17°F, 7,000 Btu/h at 47°F, 6,000 Btu/h at 95°F. 0 2,000 4,000 6,000 8,000 Btu/h 6,700 5°F 5,900 17°F 7,000 47°F 6,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 6,000 Btu mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 7,000 Btu/h of heat at 47°F, 5,900 Btu/h at 17°F, and 6,700 Btu/h at 5°F, 96% of its 47°F rating. It delivers 6,000 Btu/h of cooling at 95°F. At 5°F that is 800 Btu/h short of the example heating load of 7,500 Btu/h; at 95°F it is 2,500 Btu/h above the example cooling load of 3,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 6,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 300 sq ft where winters reach 5°F: heating runs from 7,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 210434544 · listed by C&H · certified Mar 4, 2025 · 3 pairings on 2 certificates share these values

Rebates where you live

Meets the recorded equipment thresholds of 57 programs in 32 states, provinces, or territories:Alabama (1), Arizona (1), California (2), Colorado (2), Delaware (2), Idaho (2), Illinois (1), Kentucky (1), Maine (2), Maryland (3), Michigan (2), Minnesota (1), Mississippi (2), Nevada (1), New Hampshire (1), New Jersey (7), New York (4), Oregon (2), Pennsylvania (4), Tennessee (1), Texas (2), Utah (1), Vermont (3), Washington (2), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 57 programs by state and province

Alabama

Arizona

California

Colorado

Delaware

Idaho

Illinois

Kentucky

Maine

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

Oregon

Pennsylvania

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 6,000 Btu mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 6,7001.96 kW −13% 2.06
17°Ffull speed 5,9001.73 kW −26% NR
47°Fnormal speed 7,0002.05 kW 0% NR
95°Fcooling, full load 6,0001.76 kW — NR

EER2 13.8 in that test. SEER2 23.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
0.95kW
Electrical input in the 95°F cooling test
0.43kW
Seasonal average heating COP
2.87

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 6,000 Btu heat pumps

6,000 Btu mini-split models

This pairing at 5°F
6,700 Btu/h
This unit at 5°F median across its pairings
6,700 Btu/h
Median of 6,000 Btu mini-split models at 5°F
7,700 Btu/h
Models in this group
82

This unit is above 1% of them, at number 81 of 82 by heat at 5°F. The middle half of the group runs 7,500 to 9,950 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 6,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 79th of 82 (tied); HSPF2, 79th of 82 (tied). Models without that figure are left out.

Similar ratings at 47°F

These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • DIRM4-06HXPRO28-1Z: The same 7,000 Btu/h rating at 47°F; 7,700 Btu/h at 5°F (this model: 6,700).
  • 4PAMSHH06-SZO: The same 7,000 Btu/h rating at 47°F; HSPF2 14.6 (this model: 9.8).
  • LBHB06DVWO: The same 7,000 Btu/h rating at 47°F; HSPF2 12.0 (this model: 9.8).

Closest models by heat at 5°F

Every 6,000 Btu unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 6,700 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42160–280
MildTypical16–26260–420
MildTight, well insulated10–18370–670
ColdDrafty, little insulation28–52130–240
ColdTypical18–30220–370
ColdTight, well insulated12–22300–560
Very coldDrafty, little insulation32–58120–210
Very coldTypical22–38180–300
Very coldTight, well insulated16–28240–420

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for CH-06OLVWM-115VO

3 pairings · 2 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for CH-06OLVWM-115VO
This pairingAll pairings
Heating
Heat output at 47°F normal speed 7,000 Btu/h 7,000 Btu/h
Heat output at 17°F full speed 5,900 Btu/h 5,900 Btu/h
Heat output at 5°F full speed 6,700 Btu/h 6,700 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 96%
COP at 5°F full speed 2.06 2.06
HSPF2 Region IV 9.8 9.8
Cooling
Cooling capacity at 95°F full-load test 6,000 Btu/h 6,000 Btu/h
EER2 at 95°F 13.8 13.8
SEER2 cooling season 23.0 23.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit CH-06OLVWM-115VI 1 indoor unit
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified CH-06OLVWM-115VO

Pairings, by indoor-unit class

1 indoor unit · 3 certified pairings

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 1 indoor unit

  1. CH-06OLVWM-115VI (the pairing on screen) C&H 6,700 Btu/hat 5°F, full speed

    3 pairings · 47°F 7,000 Btu/h · 95°F cooling 6,000 Btu/h · Cold output 96% · COP 2.06

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
CH-06OLVWM-115VI (the pairing on screen) C&H 6,700 7,000 6,000 96% 2.06 NC 3

The share is heat output at 5°F divided by the 47°F rating.

Showing 1 of 1 indoor unit

Sold as, and units with identical certified values

Brands listing this model number

Other brands that list these model numbers

Model number as listed

Variants of the same model number

2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

History and definitions

Other CH series models by nominal cooling size: CH-NY06MIA-115VO (6,000 Btu), CH-ES09-230VO (9,000 Btu), CH-HPR09-230VO (9,000 Btu), CH-NY09MIA-115VO (9,000 Btu), CH-NY09MIA-230VO (9,000 Btu), CH-ES12-115VO (12,000 Btu), CH-ES12-230VO (12,000 Btu), CH-HPR18-230VO (18,000 Btu); more models from this brand.

Other CH series models by nominal cooling size: CH-NY06MIA-115VO (6,000 Btu), CH-ES09-230VO (9,000 Btu), CH-HPR09-230VO (9,000 Btu), CH-NY09MIA-115VO (9,000 Btu), CH-NY09MIA-230VO (9,000 Btu), CH-ES12-115VO (12,000 Btu), CH-ES12-230VO (12,000 Btu), CH-HPR18-230VO (18,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Mar 4, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “CH-06OLVWM-115VO — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/ch-06olvwm-115vo