D5CPRAH06AAK
D5CPRAH06AAK is in the certified data.
Its certified full-speed heating output at 5°F is 13,500 Btu/h3.96 kW, 150% of its 47°F rating (tests at different compressor speeds) across its certified pairings.
Airquest, Arcoaire + 9 more · mini-split heat pump
D5CPRAH06AAK is in the certified data as of Sep 19, 2026. D5CPRAH06AAK changed its certified HSPF2 on 11 pairings from 29.0 to 15.6 in the certified data between August 2025 and September 2026.
- 6,000 Btu
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
9,0002.64NR
No 47°F rating for this pairing.
11,0003.22NR at 17°F
13,5003.96NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 9,000 Btu/h2.64 kW of heat at 47°F, 11,000 Btu/h3.22 kW at 17°F, and 13,500 Btu/h3.96 kW at 5°F, 150% of its 47°F rating. It delivers 6,000 Btu/h1.76 kW of cooling at 95°F. At 5°F that is 6,000 Btu/h1.76 kW above the example heating load of 7,500 Btu/h2.20 kW; at 95°F it is 2,500 Btu/h0.73 kW above the example cooling load of 3,500 Btu/h1.03 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 6,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 300 sq ft where winters reach 5°F: heating runs from 7,500 Btu/h2.20 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,500 Btu/h1.03 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215413211 · listed by Arcoaire · certified Jan 14, 2026 · 11 pairings on 11 certificates share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 13,5003.96 kW | +75% | 2.00 | |
| 17°Ffull speed | 11,0003.22 kW | +38% | NR | |
| 47°Fnormal speed | 9,0002.64 kW | +29% | NR | |
| 95°Fcooling, full load | 6,0001.76 kW | — | NR |
EER2 16.5 in that test. SEER2 33.1 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.98kW
- Electrical input in the 95°F cooling test
- 0.36kW
- Seasonal average heating COP
- 4.57
These exclude backup resistance heat.
How it compares with other 6,000 Btu heat pumps
6,000 Btu mini-split models
- This pairing at 5°F
- 13,500 Btu/h3.96 kWNR
- This unit at 5°F median across its pairings
- 13,500 Btu/h3.96 kW
- Median of 6,000 Btu mini-split models at 5°F
- 7,700 Btu/h2.26 kW
- Models in this group
- 82
This unit is above 84% of them, at number 13 of 82 by heat at 5°F. The middle half of the group runs 7,500 to 9,950 Btu/h.
Closest models by heat at 5°F
- 37MPRAQ06AA3Bryant, Carrier + 3 more · 13,500 Btu/h
- MO1SS-H06B-2AMidea · 13,500 Btu/h
- MOX430-06HFN10-M1HMDV · 13,500 Btu/h
- MUZ-FX06NLHZMitsubishi Electric · 12,600 Btu/h
- MUZ-FS06NAAmerican Standard / Mitsubishi Electric, Mitsubishi Electric + 1 more · 10,500 Btu/h
- MUZ-FS06NAHAmerican Standard / Mitsubishi Electric, Mitsubishi Electric + 1 more · 10,500 Btu/h
Every 6,000 Btu unit, ranked by cooling efficiency, then heating efficiency
Certified values for D5CPRAH06AAK
11 pairings · 11 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 9,000 Btu/h2.64 kWNR | 9,000 Btu/h2.64 kW |
| Heat output at 17°F full speed | 11,000 Btu/h3.22 kWNR | 11,000 Btu/h3.22 kW |
| Heat output at 5°F full speed | 13,500 Btu/h3.96 kWNR | 13,500 Btu/h3.96 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 150%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 15.6NR | 15.6 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 6,000 Btu/h1.76 kWNR | 6,000 Btu/h1.76 kW |
| EER2 at 95°F | 16.5NR | 16.5 |
| SEER2 cooling season | 33.1NR | 33.1 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | D5FPHAH06XAK | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | D5CPRAH06AAK | |
Pairings, by indoor-unit class
1 indoor unit · 11 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
D5FPHAH06XAK (the pairing on screen) AIRQUEST 13,500 Btu/h3.96 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| D5FPHAH06XAK (the pairing on screen) | AIRQUEST | 13,5003.96 | 9,0002.64 | 6,0001.76 | 150% | 2.00 | Yes | 11 |
Sold as, and units with identical certified values
Brands listing this model number
- Airquest1 pairing
- Arcoaire1 pairing
- Comfortmaker1 pairing
- Day & Night1 pairing
- Heil1 pairing
- Keeprite1 pairing
- Kenmore1 pairing
- LPS Legacy1 pairing
- Midea1 pairing
- Smart Comfort1 pairing
- Tempstar1 pairing
Other brands that list these model numbers
- Are Airquest and Arcoaire heat pumps the same?174 shared model numbers
- Are Airquest and Heil heat pumps the same?174 shared model numbers
- Are Airquest and Keeprite heat pumps the same?152 shared model numbers
- Are Airquest and Comfortmaker heat pumps the same?151 shared model numbers
- Are Airquest and Day & Night heat pumps the same?151 shared model numbers
- Are Airquest and Tempstar heat pumps the same?151 shared model numbers
- Are Airquest and Kenmore heat pumps the same?135 shared model numbers
- Are Airquest and Smart Comfort heat pumps the same?107 shared model numbers
Model number as listed
- D5CPRAH06AAK 11 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- D5CPRAH06AAK changed its certified HSPF2 on 11 pairings from 29.0 to 15.6 in the certified data between August 2025 and September 2026.
- D5CPRAH06AAK was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jan 14, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read