MUZ-FS06NAH
MUZ-FS06NAH is in the certified data.
Its certified full-speed heating output at 5°F is 10,500 Btu/h3.08 kW, 121% of its 47°F rating (tests at different compressor speeds) across its certified pairings.
American Standard / Mitsubishi Electric, Mitsubishi Electric + 1 more · mini-split heat pump
MUZ-FS06NAH is in the certified data as of Sep 19, 2026.
- 6,000 Btu
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
8,7002.55NR
No 47°F rating for this pairing.
5,9001.73NR at 17°F
10,5003.08NR at 5°F
Btu/hkW, certified
2.46NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 8,700 Btu/h2.55 kW of heat at 47°F, 5,900 Btu/h1.73 kW at 17°F, and 10,500 Btu/h3.08 kW at 5°F, 121% of its 47°F rating. It delivers 6,000 Btu/h1.76 kW of cooling at 95°F. At 5°F that is 3,000 Btu/h0.88 kW above the example heating load of 7,500 Btu/h2.20 kW; at 95°F it is 2,500 Btu/h0.73 kW above the example cooling load of 3,500 Btu/h1.03 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 6,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 300 sq ft where winters reach 5°F: heating runs from 7,500 Btu/h2.20 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,500 Btu/h1.03 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 209832200 · listed by Mitsubishi Electric · certified Feb 24, 2025 · 3 pairings on 3 certificates share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 10,5003.08 kW | +36% | 2.46 | |
| 17°Ffull speed | 5,9001.73 kW | −26% | NR | |
| 47°Fnormal speed | 8,7002.55 kW | +24% | NR | |
| 95°Fcooling, full load | 6,0001.76 kW | — | NR |
EER2 19.05 in that test. SEER2 32.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.25kW
- Electrical input in the 95°F cooling test
- 0.31kW
- Seasonal average heating COP
- 3.19
These exclude backup resistance heat.
How it compares with other 6,000 Btu heat pumps
6,000 Btu mini-split models
- This pairing at 5°F
- 10,500 Btu/h3.08 kWNR
- This unit at 5°F median across its pairings
- 10,500 Btu/h3.08 kW
- Median of 6,000 Btu mini-split models at 5°F
- 7,700 Btu/h2.26 kW
- Models in this group
- 82
This unit is above 74% of them, at number 21 of 82 by heat at 5°F. The middle half of the group runs 7,500 to 9,950 Btu/h.
Closest models by heat at 5°F
- MOX430-06HFN10-M1HMDV · 13,500 Btu/h
- MUZ-FX06NLHZMitsubishi Electric · 12,600 Btu/h
- MUZ-FS06NAAmerican Standard / Mitsubishi Electric, Mitsubishi Electric + 1 more · 10,500 Btu/h
- MOX230-06HFN10-M1MDV · 8,300 Btu/h
- KEENUMHP06AAKEEN Home · 8,100 Btu/h
- 37MAHAQ06AA3Bryant, Carrier + 3 more · 7,800 Btu/h
Every 6,000 Btu unit, ranked by cooling efficiency, then heating efficiency
Certified values for MUZ-FS06NAH
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 8,700 Btu/h2.55 kWNR | 8,700 Btu/h2.55 kW |
| Heat output at 17°F full speed | 5,900 Btu/h1.73 kWNR | 5,900 Btu/h1.73 kW |
| Heat output at 5°F full speed | 10,500 Btu/h3.08 kWNR | 10,500 Btu/h3.08 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 121%NR | |
| COP at 5°F full speed | 2.46NR | 2.46 |
| HSPF2 Region IV | 10.9NR | 10.9 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 6,000 Btu/h1.76 kWNR | 6,000 Btu/h1.76 kW |
| EER2 at 95°F | 19.05NR | 19.05 |
| SEER2 cooling season | 32.2NR | 32.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | MSZ-FS06NA*** | 3 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MUZ-FS06NAH*** | |
Pairings, by indoor-unit class
3 indoor units · 3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 3 indoor units
-
MSZ-FS06NA*** (the pairing on screen) Mitsubishi Electric 10,500 Btu/h3.08 kWat 5°F, full speed
-
NAXWPH06B112A* (the pairing on screen) American Standard / Mitsubishi Electric 10,500 Btu/h3.08 kWat 5°F, full speed
-
NTXWPH06B112A* (the pairing on screen) Trane / Mitsubishi Electric 10,500 Btu/h3.08 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MSZ-FS06NA*** (the pairing on screen) | Mitsubishi Electric | 10,5003.08 | 8,7002.55 | 6,0001.76 | 121% | 2.46 | Yes | 1 |
| NAXWPH06B112A* (the pairing on screen) | American Standard / Mitsubishi Electric | 10,5003.08 | 8,7002.55 | 6,0001.76 | 121% | 2.46 | Yes | 1 |
| NTXWPH06B112A* (the pairing on screen) | Trane / Mitsubishi Electric | 10,5003.08 | 8,7002.55 | 6,0001.76 | 121% | 2.46 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
- American Standard / Mitsubishi Electric1 pairing
- Mitsubishi Electric1 pairing
- Trane / Mitsubishi Electric1 pairing
Other brands that list these model numbers
- American Standard / Mitsubishi Electric vs Trane / Mitsubishi Electric33 shared model numbers
- American Standard / Mitsubishi Electric vs Mitsubishi Electric24 shared model numbers
- Are Mitsubishi Electric and Trane / Mitsubishi Electric the same?48 shared model numbers
Model number as listed
- MUZ-FS06NAH*** 3 pairings
Variants of the same model number
3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Feb 24, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read