D5CUHAH36AAK
D5CUHAH36AAK is in the certified data.
Its certified full-speed heating output at 5°F is 29,800–39,000 Btu/h8.73–11.43 kW, 78–105% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Airquest, Arcoaire + 15 more · central heat pump
D5CUHAH36AAK is in the certified data as of Sep 19, 2026. D5CUHAH36AAK changed its certified heat output at 17°F on 13 pairings from 31,000 Btu/h to 33,000 Btu/h in the certified data between August 2025 and September 2026.
- 36,000 Btu (3-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
38,00011.14NR
No 47°F rating for this pairing.
25,2007.39NR at 17°F
30,4008.91NR at 5°F
Btu/hkW, certified
1.75NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 38,000 Btu/h11.14 kW of heat at 47°F, 25,200 Btu/h7.39 kW at 17°F, and 30,400 Btu/h8.91 kW at 5°F, 80% of its 47°F rating. It delivers 35,600 Btu/h10.43 kW of cooling at 95°F. At 5°F that is 3,900 Btu/h1.14 kW above the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 22,600 Btu/h6.62 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218492044 · listed by Heil · certified Jun 16, 2026 · 56 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 30,4008.91 kW | +15% | 1.75 | |
| 17°Ffull speed | 25,2007.39 kW | −4% | NR | |
| 47°Fnormal speed | 38,00011.14 kW | +8% | NR | |
| 95°Fcooling, full load | 35,60010.43 kW | — | NR |
EER2 9.5 in that test. SEER2 15.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.09kW
- Electrical input in the 95°F cooling test
- 3.75kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 30,400 Btu/h8.91 kWNR
- This unit at 5°F median across its pairings
- 30,400 Btu/h8.91 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 68% of them, at number 146 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- RP17AY36AJVCRheem and Ruud · 31,000 Btu/h
- PHE6B3624Champion, Coleman + 4 more · 30,600 Btu/h
- 37MUHAQ36AA3Bryant, Carrier + 3 more · 30,400 Btu/h
- AZPN/C36WDUIDKepler · 30,000 Btu/h
- BOHA-36RTB-M18SBosch · 30,000 Btu/h
- DLCURAH36ACKMidea · 30,000 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for D5CUHAH36AAK
2,634 pairings · 2,634 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 38,000 Btu/h11.14 kWNR | 37,000–40,000 Btu/h10.84–11.72 kW |
| Heat output at 17°F full speed | 25,200 Btu/h7.39 kWNR | 24,600–33,000 Btu/h7.21–9.67 kW |
| Heat output at 5°F full speed | 30,400 Btu/h8.91 kWNR | 29,800–39,000 Btu/h8.73–11.43 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 80%NR | |
| COP at 5°F full speed | 1.75NR | 1.75–1.90 |
| HSPF2 Region IV | 8.1NR | 8.1–10.3 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 35,600 Btu/h10.43 kWNR | 34,200–38,000 Btu/h10.02–11.14 kW |
| EER2 at 95°F | 9.5NR | 9.4–12.0 |
| SEER2 cooling season | 15.5NR | 15.2–18.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | ESH5X48M12A* | 26 indoor units |
| Furnace | *80VSL0451412B* | 56 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | D5CUHAH36AAK | |
Pairings, by indoor-unit class
26 indoor units · 2,634 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 9 indoor units
-
EA*5X37M21A* (the pairing on screen) brand not stated 30,200 Btu/h8.85 kWat 5°F, full speed
-
EA*5X42M21A* (the pairing on screen) brand not stated 30,800 Btu/h9.03 kWat 5°F, full speed
-
EA*5X43M21A* (the pairing on screen) brand not stated 30,200 Btu/h8.85 kWat 5°F, full speed
-
EA*5X48M21A* (the pairing on screen) brand not stated 30,000 Btu/h8.79 kWat 5°F, full speed
-
ESH5X48M12A* (the pairing on screen) brand not stated 30,400 Btu/h8.91 kWat 5°F, full speed
-
ESH5X42M12A* (the pairing on screen) brand not stated 30,600 Btu/h8.97 kWat 5°F, full speed
-
ESH5X36M12A* (the pairing on screen) brand not stated 30,800 Btu/h9.03 kWat 5°F, full speed
-
EA*5X36M17A* (the pairing on screen) brand not stated 31,000 Btu/h9.09 kWat 5°F, full speed
-
EA*5X37M17A* (the pairing on screen) brand not stated 30,600 Btu/h8.97 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| EA*5X37M21A* (the pairing on screen) | — | 30,2008.85 | 38,00011.14 | 36,20010.61 | 79% | 1.84 | Yes | 370 |
| EA*5X42M21A* (the pairing on screen) | — | 30,8009.03 | 38,50011.28 | 34,80010.20 | 81% | 1.78 | Yes | 370 |
| EA*5X43M21A* (the pairing on screen) | — | 30,2008.85 | 38,00011.14 | 36,20010.61 | 79% | 1.84 | Yes | 370 |
| EA*5X48M21A* (the pairing on screen) | — | 30,0008.79 | 38,00011.14 | 35,40010.37 | 79% | 1.82 | Yes | 370 |
| ESH5X48M12A* (the pairing on screen) | — | 30,4008.91 | 38,00011.14 | 35,80010.49 | 80% | 1.75 | Yes | 304 |
| ESH5X42M12A* (the pairing on screen) | — | 30,6008.97 | 38,00011.14 | 35,60010.43 | 81% | 1.75 | Yes | 232 |
| ESH5X36M12A* (the pairing on screen) | — | 30,8009.03 | 38,50011.28 | 35,60010.43 | 80% | 1.75 | Yes | 152 |
| EA*5X36M17A* (the pairing on screen) | — | 31,0009.09 | 38,50011.28 | 34,40010.08 | 81% | 1.75 | Yes | 144 |
| EA*5X37M17A* (the pairing on screen) | — | 30,6008.97 | 38,50011.28 | 35,60010.43 | 80% | 1.83 | Yes | 144 |
Air handler · 1 indoor unit
-
D5MUWAQ36XA3 (the pairing on screen) brand not stated 34,600 Btu/h10.14 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| D5MUWAQ36XA3 (the pairing on screen) | — | 34,60010.14 | 37,00010.84 | 36,00010.55 | 94% | 1.80 | Yes | 17 |
Sold as, and units with identical certified values
Brands listing this model number
- Airquest328 pairings
- Arcoaire324 pairings
- Bryant1 pairing
- Carrier1 pairing
- Comfortmaker324 pairings
- Day & Night324 pairings
- Grandaire5 pairings
- Heil324 pairings
- Keeprite324 pairings
- Kenmore5 pairings
- LPS Legacy5 pairings
- Midea7 pairings
- Payne1 pairing
- Smart Comfort328 pairings
- Tempstar324 pairings
- Viessmann8 pairings
- WeatherMaker1 pairing
Other brands that list these model numbers
- Are Airquest and Arcoaire heat pumps the same?174 shared model numbers
- Are Airquest and Heil heat pumps the same?174 shared model numbers
- Are Airquest and Keeprite heat pumps the same?152 shared model numbers
- Are Airquest and Comfortmaker heat pumps the same?151 shared model numbers
- Are Airquest and Day & Night heat pumps the same?151 shared model numbers
- Are Airquest and Tempstar heat pumps the same?151 shared model numbers
- Are Airquest and Kenmore heat pumps the same?135 shared model numbers
- Are Airquest and Smart Comfort heat pumps the same?107 shared model numbers
Model number as listed
- D5CUHAH36AAK 89 pairings
- D5CUHAH36AAK+KSAIC0701230 2,537 pairings
- D5CUHAH36AAK+TIC2025-0016 8 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- D5CUHAH36AAK changed its certified heat output at 17°F on 13 pairings from 31,000 Btu/h to 33,000 Btu/h in the certified data between August 2025 and September 2026.
- D5CUHAH36AAK was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 16, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read