DLCMHBH36DAK
DLCMHBH36DAK is in the certified data.
Its certified full-speed heating output at 5°F is 33,000–36,000 Btu/h9.67–10.55 kW, 89–97% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Airquest, Arcoaire + 10 more · mini-split heat pump
DLCMHBH36DAK is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
37,00010.84NR
No 47°F rating for this pairing.
35,00010.26NR at 17°F
34,40010.08NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 37,000 Btu/h10.84 kW of heat at 47°F, 35,000 Btu/h10.26 kW at 17°F, and 34,400 Btu/h10.08 kW at 5°F, 93% of its 47°F rating. It delivers 36,000 Btu/h10.55 kW of cooling at 95°F. At 5°F that is 3,400 Btu/h1.00 kW above the example heating load of 31,000 Btu/h9.09 kW; at 95°F it is 20,500 Btu/h6.01 kW above the example cooling load of 15,500 Btu/h4.54 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,300 sq ft where winters reach 5°F: heating runs from 31,000 Btu/h9.09 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 15,500 Btu/h4.54 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 207643004 · listed by Arcoaire · certified Mar 4, 2025 · 12 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 34,40010.08 kW | +11% | 1.80 | |
| 17°Ffull speed | 35,00010.26 kW | +18% | NR | |
| 47°Fnormal speed | 37,00010.84 kW | 0% | NR | |
| 95°Fcooling, full load | 36,00010.55 kW | — | NR |
EER2 12.1 in that test. SEER2 19.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.60kW
- Electrical input in the 95°F cooling test
- 2.98kW
- Seasonal average heating COP
- 2.89
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton mini-split models
- This pairing at 5°F
- 34,400 Btu/h10.08 kWNR
- This unit at 5°F median across its pairings
- 34,400 Btu/h10.08 kW
- Median of 3-ton mini-split models at 5°F
- 31,000 Btu/h9.09 kW
- Models in this group
- 553
This unit is above 67% of them, at number 184 of 553 by heat at 5°F. The middle half of the group runs 26,000 to 36,000 Btu/h.
Closest models by heat at 5°F
- AOUK036SSAN7Fujitsu · 35,000 Btu/h
- HVAHP036C23SHitachi · 35,000 Btu/h
- 38MGHBQ36DA3Bryant, Carrier + 3 more · 34,400 Btu/h
- M4OI-36HFN1-MEco Air and MDV · 34,400 Btu/h
- MLB036S4M-1PLennox · 34,400 Btu/h
- FPHMR36A3DFriedrich, Rheem + 1 more · 34,200 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for DLCMHBH36DAK
36 pairings · 36 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 37,000 Btu/h10.84 kWNR | 37,000 Btu/h10.84 kW |
| Heat output at 17°F full speed | 35,000 Btu/h10.26 kWNR | 35,000 Btu/h10.26 kW |
| Heat output at 5°F full speed | 34,400 Btu/h10.08 kWNR | 33,000–36,000 Btu/h9.67–10.55 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 93%NR | |
| COP at 5°F full speed | 1.80NR | 1.70–1.90 |
| HSPF2 Region IV | 9.9NR | 9.7–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 36,000 Btu/h10.55 kWNR | 36,000 Btu/h10.55 kW |
| EER2 at 95°F | 12.1NR | 11.7–12.5 |
| SEER2 cooling season | 19.5NR | 19.0–20.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | DLCMHBH36DAK | |
Pairings, by indoor-unit class
36 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) AIRQUEST 34,400 Btu/h10.08 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | AIRQUEST | 34,40010.08 | 37,00010.84 | 36,00010.55 | 93% | 1.80 | Yes | 36 |
Sold as, and units with identical certified values
Brands listing this model number
- Airquest3 pairings
- Arcoaire3 pairings
- Comfortmaker3 pairings
- Day & Night3 pairings
- Heil3 pairings
- Keeprite3 pairings
- Kenmore3 pairings
- LPS Legacy3 pairings
- Midea3 pairings
- Smart Comfort3 pairings
- Tempstar3 pairings
- Viessmann3 pairings
Other brands that list these model numbers
- Are Airquest and Arcoaire heat pumps the same?174 shared model numbers
- Are Airquest and Heil heat pumps the same?174 shared model numbers
- Are Airquest and Keeprite heat pumps the same?152 shared model numbers
- Are Airquest and Comfortmaker heat pumps the same?151 shared model numbers
- Are Airquest and Day & Night heat pumps the same?151 shared model numbers
- Are Airquest and Tempstar heat pumps the same?151 shared model numbers
- Are Airquest and Kenmore heat pumps the same?135 shared model numbers
- Are Airquest and Smart Comfort heat pumps the same?107 shared model numbers
Model number as listed
- DLCMHBH36DAK 36 pairings
Variants of the same model number
9 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 3PAMS36-HH-MZO4PerfectAire
- BMM36HHCBlueridge
- DRA4H36M1ADuraSTAR
- EMH-4O36BBHEco AC
- HMZ36H424ZMOSea Breeze
- HO-MQ36-AB-QMitsutomo
- LMUHB36DOLBG Products
- SHC4Z36VE2AGSlimAir
8 of 9 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 4, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read