DLCSRBH18AAK

DLCSRBH18AAK is in the certified data.

Its certified full-speed heating output at 5°F is 16,000–18,000 Btu/h, 84–100% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Airquest, Arcoaire + 12 more · mini-split heat pump

DLCSRBH18AAK is in the certified data as of Sep 19, 2026.

201 certified pairings with 9 different figures. See all

Certified heating and cooling

Heating at 47°F

19,000

15,400 at 17°F

17,000 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

18,000

Btu/h, certified

EER2 11.7 at 95°F

SEER2 17.6

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for DLCSRBH18AAK, by outdoor temperature Heating: 17,000 Btu/h at 5°F, 15,400 Btu/h at 17°F, 19,000 Btu/h at 47°F. Cooling: 18,000 Btu/h at 95°F. The bars start at zero. Median of 1.5-ton mini-split models: 14,200 Btu/h at 5°F, 14,800 Btu/h at 17°F, 18,000 Btu/h at 47°F, 18,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 Btu/h 17,000 5°F 15,400 17°F 19,000 47°F 18,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 1.5-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 19,000 Btu/h of heat at 47°F, 15,400 Btu/h at 17°F, and 17,000 Btu/h at 5°F, 89% of its 47°F rating. It delivers 18,000 Btu/h of cooling at 95°F. At 5°F that is 3,000 Btu/h above the example heating load of 14,000 Btu/h; at 95°F it is 11,000 Btu/h above the example cooling load of 7,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 207826595 · listed by Arcoaire · certified Apr 9, 2026 · 23 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 1.5-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 17,0004.98 kW +20% 2.00
17°Ffull speed 15,4004.51 kW +4% NR
47°Fnormal speed 19,0005.57 kW +6% NR
95°Fcooling, full load 18,0005.28 kW — NR

EER2 11.7 in that test. SEER2 17.6 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.49kW
Electrical input in the 95°F cooling test
1.54kW
Seasonal average heating COP
2.81

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 18,000 Btu heat pumps

1.5-ton mini-split models

This pairing at 5°F
17,000 Btu/h
This unit at 5°F median across its pairings
17,000 Btu/h
Median of 1.5-ton mini-split models at 5°F
14,200 Btu/h
Models in this group
1,110

This unit is above 63% of them, at number 406 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for DLCSRBH18AAK

201 pairings · 197 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for DLCSRBH18AAK
This pairingAll pairings
Heating
Heat output at 47°F normal speed 19,000 Btu/h 17,000–20,000 Btu/h
Heat output at 17°F full speed 15,400 Btu/h 11,100–15,800 Btu/h
Heat output at 5°F full speed 17,000 Btu/h 16,000–18,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 89%
COP at 5°F full speed 2.00 1.75–2.20
HSPF2 Region IV 9.6 9.5–11.3
Cooling
Cooling capacity at 95°F full-load test 18,000 Btu/h 16,000–18,000 Btu/h
EER2 at 95°F 11.7 11.7–13.0
SEER2 cooling season 17.6 17.6–22.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit DLFSABH18XBK 17 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified DLCSRBH18AAK

Pairings, by indoor-unit class

17 indoor units · 201 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 1 indoor unit

  1. DLFSABH18XBK (the pairing on screen) brand not stated 17,000 Btu/hat 5°F, full speed

    12 pairings · 47°F 19,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 89% · COP 2.00

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
DLFSABH18XBK (the pairing on screen) — 17,000 19,000 18,000 89% 2.00 Yes 12

Ductless indoor · 9 indoor units

  1. DLFSCAH18XAK AIRQUEST 16,000 Btu/hat 5°F, full speed

    14 pairings · 47°F 17,000 Btu/h · 95°F cooling 16,000 Btu/h · Cold output 94% · COP 1.75

  2. DLFSDAH24XAK AIRQUEST 16,000 Btu/hat 5°F, full speed

    13 pairings · 47°F 19,000 Btu/h · 95°F cooling 17,500 Btu/h · Cold output 84% · COP 2.00

  3. DLFSHBH18XAK AIRQUEST 17,200 Btu/hat 5°F, full speed

    13 pairings · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 96% · COP 1.89

  4. DLFCCAH18XAK AIRQUEST 16,700 Btu/hat 5°F, full speed

    12 pairings · 47°F 20,000 Btu/h · 95°F cooling 16,700 Btu/h · Cold output 84% · COP 1.93

  5. DLFSDAH18XAK AIRQUEST 17,700 Btu/hat 5°F, full speed

    12 pairings · 47°F 19,000 Btu/h · 95°F cooling 17,000 Btu/h · Cold output 93% · COP 1.85

  6. DLFSDAH18XHK AIRQUEST 18,000 Btu/hat 5°F, full speed

    12 pairings · 47°F 19,000 Btu/h · 95°F cooling 17,500 Btu/h · Cold output 95% · COP 2.20

  7. DLFSFAH18XAK AIRQUEST 16,800 Btu/hat 5°F, full speed

    12 pairings · 47°F 18,000 Btu/h · 95°F cooling 17,000 Btu/h · Cold output 93% · COP 1.86

  8. DLFSHCH18XAK AIRQUEST 18,000 Btu/hat 5°F, full speed

    12 pairings · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 100% · COP 1.80

  9. DLFSOAH18XAK AIRQUEST 16,700 Btu/hat 5°F, full speed

    12 pairings · 47°F 20,000 Btu/h · 95°F cooling 16,700 Btu/h · Cold output 84% · COP 1.93

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
DLFSCAH18XAK AIRQUEST 16,000 17,000 16,000 94% 1.75 Yes 14
DLFSDAH24XAK AIRQUEST 16,000 19,000 17,500 84% 2.00 Yes 13
DLFSHBH18XAK AIRQUEST 17,200 18,000 18,000 96% 1.89 Yes 13
DLFCCAH18XAK AIRQUEST 16,700 20,000 16,700 84% 1.93 Yes 12
DLFSDAH18XAK AIRQUEST 17,700 19,000 17,000 93% 1.85 Yes 12
DLFSDAH18XHK AIRQUEST 18,000 19,000 17,500 95% 2.20 Yes 12
DLFSFAH18XAK AIRQUEST 16,800 18,000 17,000 93% 1.86 Yes 12
DLFSHCH18XAK AIRQUEST 18,000 18,000 18,000 100% 1.80 Yes 12
DLFSOAH18XAK AIRQUEST 16,700 20,000 16,700 84% 1.93 Yes 12

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 17 indoor units All 201 certified pairings

Sold as, and units with identical certified values

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Apr 9, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page