DMA09HOS42230E4
DMA09HOS42230E4 is in the certified data.
Its certified full-speed heating output at 5°F is 13,700 Btu/h4.02 kW, 114% of its 47°F rating (tests at different compressor speeds) in its certified pairing.
MoovAir · mini-split heat pump
DMA09HOS42230E4 is in the certified data as of Sep 19, 2026. DMA09HOS42230E4 changed its certified HSPF2 on AHRI certificate 207742499 from 18.0 to 12.0 in the certified data between August 2025 and September 2026.
- 9,000 Btu
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
12,0003.52NR
No 47°F rating for this pairing.
10,4003.05NR at 17°F
13,7004.02NR at 5°F
Btu/hkW, certified
1.85NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 12,000 Btu/h3.52 kW of heat at 47°F, 10,400 Btu/h3.05 kW at 17°F, and 13,700 Btu/h4.02 kW at 5°F, 114% of its 47°F rating. It delivers 9,000 Btu/h2.64 kW of cooling at 95°F. At 5°F that is 6,200 Btu/h1.82 kW above the example heating load of 7,500 Btu/h2.20 kW; at 95°F it is 5,500 Btu/h1.61 kW above the example cooling load of 3,500 Btu/h1.03 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 9,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 300 sq ft where winters reach 5°F: heating runs from 7,500 Btu/h2.20 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,500 Btu/h1.03 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 207742499 · listed by MOOVAIR · certified Jun 13, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 13,7004.02 kW | +78% | 1.85 | |
| 17°Ffull speed | 10,4003.05 kW | +30% | NR | |
| 47°Fnormal speed | 12,0003.52 kW | +20% | NR | |
| 95°Fcooling, full load | 9,0002.64 kW | — | NR |
EER2 16.0 in that test. SEER2 28.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.17kW
- Electrical input in the 95°F cooling test
- 0.56kW
- Seasonal average heating COP
- 3.52
These exclude backup resistance heat.
How it compares with other 9,000 Btu heat pumps
9,000 Btu mini-split models
- This pairing at 5°F
- 13,700 Btu/h4.02 kWNR
- This unit at 5°F median across its pairings
- 13,700 Btu/h4.02 kW
- Median of 9,000 Btu mini-split models at 5°F
- 7,700 Btu/h2.26 kW
- Models in this group
- 894
This unit is above 99% of them, at number 11 of 894 by heat at 5°F. The middle half of the group runs 7,000 to 9,500 Btu/h.
Closest models by heat at 5°F
- MUZ-FX09NLHZMitsubishi Electric · 14,700 Btu/h
- 38MPRBQ09AA3Bryant, Carrier + 3 more · 13,700 Btu/h
- DLCPRBH09AAKAirquest, Arcoaire + 10 more · 13,700 Btu/h
- MOX430-09HFN1-MZG5WMDV and Midea · 13,700 Btu/h
- 37MPRAQ09AA3Bryant, Carrier + 3 more · 13,500 Btu/h
- D5CPRAH09AAKAirquest, Arcoaire + 9 more · 13,500 Btu/h
Every 9,000 Btu unit, ranked by cooling efficiency, then heating efficiency
Certified values for DMA09HOS42230E4
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 12,000 Btu/h3.52 kWNR | 12,000 Btu/h3.52 kW |
| Heat output at 17°F full speed | 10,400 Btu/h3.05 kWNR | 10,400 Btu/h3.05 kW |
| Heat output at 5°F full speed | 13,700 Btu/h4.02 kWNR | 13,700 Btu/h4.02 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 114%NR | |
| COP at 5°F full speed | 1.85NR | 1.85 |
| HSPF2 Region IV | 12.0NR | 12.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 9,000 Btu/h2.64 kWNR | 9,000 Btu/h2.64 kW |
| EER2 at 95°F | 16.0NR | 16.0 |
| SEER2 cooling season | 28.5NR | 28.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | DMA09HIW42230E4 | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | DMA09HOS42230E4 | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
DMA09HIW42230E4 (the pairing on screen) MOOVAIR 13,700 Btu/h4.02 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| DMA09HIW42230E4 (the pairing on screen) | MOOVAIR | 13,7004.02 | 12,0003.52 | 9,0002.64 | 114% | 1.85 | Yes | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- DMA09HOS42230E4 changed its certified HSPF2 on AHRI certificate 207742499 from 18.0 to 12.0 in the certified data between August 2025 and September 2026.
- DMA09HOS42230E4 first appeared in the certified data between March 2025 and May 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 13, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read