ESHEA18R2AN1
ESHEA18R2AN1 is in the certified data.
Its certified full-speed heating output at 5°F is 11,400 Btu/h3.34 kW, 63% of its 47°F rating (tests at different compressor speeds) across its certified pairings.
Elios · central heat pump
ESHEA18R2AN1 is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
18,0005.28NR
No 47°F rating for this pairing.
11,8003.46NR at 17°F
11,4003.34NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 18,000 Btu/h5.28 kW of heat at 47°F, 11,800 Btu/h3.46 kW at 17°F, and 11,400 Btu/h3.34 kW at 5°F, 63% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 400 Btu/h0.12 kW above the example heating load of 11,000 Btu/h3.22 kW; at 95°F it is 12,500 Btu/h3.66 kW above the example cooling load of 5,500 Btu/h1.61 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 450 sq ft where winters reach 5°F: heating runs from 11,000 Btu/h3.22 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,500 Btu/h1.61 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217177266 · listed by Elios · certified Nov 24, 2025 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 11,4003.34 kW | +2% | 1.80 | |
| 17°Ffull speed | 11,8003.46 kW | −6% | NR | |
| 47°Fnormal speed | 18,0005.28 kW | 0% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 11.5 in that test. SEER2 16.8 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.86kW
- Electrical input in the 95°F cooling test
- 1.57kW
- Seasonal average heating COP
- 2.58
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton central models
- This pairing at 5°F
- 11,400 Btu/h3.34 kWNR
- This unit at 5°F median across its pairings
- 11,400 Btu/h3.34 kW
- Median of 1.5-ton central models at 5°F
- 11,200 Btu/h3.28 kW
- Models in this group
- 243
This unit is above 51% of them, at number 120 of 243 by heat at 5°F. The middle half of the group runs 8,600 to 18,000 Btu/h.
Closest models by heat at 5°F
- MOVA-24HDN1-M16GMidea · 12,900 Btu/h
- 1824SPV0-HP-X-DMulti MFG · 12,800 Btu/h
- UCHA-18HFDCSN4UTL · 12,600 Btu/h
- 37MURAQ18AA3Bryant, Carrier + 3 more · 11,200 Btu/h
- ACIQ-18-EHPD1HVAC and ACiQ · 11,200 Btu/h
- CU-M18BAHUPanasonic · 11,200 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for ESHEA18R2AN1
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| Heat output at 17°F full speed | 11,800 Btu/h3.46 kWNR | 11,800–12,600 Btu/h3.46–3.69 kW |
| Heat output at 5°F full speed | 11,400 Btu/h3.34 kWNR | 11,400 Btu/h3.34 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 63%NR | |
| COP at 5°F full speed | 1.80NR | 1.80–2.10 |
| HSPF2 Region IV | 8.8NR | 8.8–9.4 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 11.5NR | 11.5 |
| SEER2 cooling season | 16.8NR | 16.8–18.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | GPHLA18R4AS1 | 2 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | ESHEA18R2AN1 | |
Pairings, by indoor-unit class
2 indoor units · 2 certified pairings
One row per indoor unit certified with this outdoor unit.
Air handler · 2 indoor units
-
GGHLA18R4AS1 (the pairing on screen) brand not stated 11,400 Btu/h3.34 kWat 5°F, full speed
-
GPHLA18R4AS1 (the pairing on screen) brand not stated 11,400 Btu/h3.34 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| GGHLA18R4AS1 (the pairing on screen) | — | 11,4003.34 | 18,0005.28 | 18,0005.28 | 63% | 2.10 | NC | 1 |
| GPHLA18R4AS1 (the pairing on screen) | — | 11,4003.34 | 18,0005.28 | 18,0005.28 | 63% | 1.80 | NC | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- ESHEA18R2AN1 first appeared in the certified data between June 2025 and August 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Nov 24, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read