GWH12AGC-D3DNA1A/O
Not in the certified data since Oct 18, 2026.
Its certified full-speed heating output at 5°F is 9,200 Btu/h2.70 kW, 77% of its 47°F rating (tests at different compressor speeds) across its certified pairings.
Gree · mini-split heat pump
- 12,000 Btu (1-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
12,0003.52NR
No 47°F rating for this pairing.
10,0002.93NR at 17°F
9,2002.70NR at 5°F
Btu/hkW, certified
1.93NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 12,000 Btu/h3.52 kW of heat at 47°F, 10,000 Btu/h2.93 kW at 17°F, and 9,200 Btu/h2.70 kW at 5°F, 77% of its 47°F rating. It delivers 12,000 Btu/h3.52 kW of cooling at 95°F. At 5°F that is 200 Btu/h0.06 kW above the example heating load of 9,000 Btu/h2.64 kW; at 95°F it is 7,000 Btu/h2.05 kW above the example cooling load of 5,000 Btu/h1.47 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 400 sq ft where winters reach 5°F: heating runs from 9,000 Btu/h2.64 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,000 Btu/h1.47 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 206395961 · listed by GREE · certified Jun 13, 2026 · 3 pairings on 3 certificates share these values
Rebates where you live
No programs list this model as meeting their recorded equipment thresholds.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 9,2002.70 kW | 0% | 1.93 | |
| 17°Ffull speed | 10,0002.93 kW | +2% | NR | |
| 47°Fnormal speed | 12,0003.52 kW | 0% | NR | |
| 95°Fcooling, full load | 12,0003.52 kW | — | NR |
EER2 12.5 in that test. SEER2 25.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.40kW
- Electrical input in the 95°F cooling test
- 0.96kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 12,000 Btu heat pumps
1-ton mini-split models
- This pairing at 5°F
- 9,200 Btu/h2.70 kWNR
- This unit at 5°F median across its pairings
- 9,200 Btu/h2.70 kW
- Median of 1-ton mini-split models at 5°F
- 9,200 Btu/h2.70 kW
- Models in this group
- 888
This unit is above 50% of them, at number 445 of 888 by heat at 5°F. The middle half of the group runs 8,400 to 11,300 Btu/h.
Closest models by heat at 5°F
- ASW-H12C5C3/P*R3DI-C5AUX · 9,200 Btu/h
- FPHSR12A1CFriedrich, Rheem + 1 more · 9,200 Btu/h
- GHS12H5MWAHD05Havells · 9,200 Btu/h
- XH12MAA2DI-20USAUX and Xtron · 9,200 Btu/h
- XH12MAA3DI-20USAUX and Xtron · 9,200 Btu/h
- YRACDJ12WHAAYork · 9,200 Btu/h
Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 9,200 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 220–380 |
| Mild | Typical | 16–26 | 350–580 |
| Mild | Tight, well insulated | 10–18 | 510–920 |
| Cold | Drafty, little insulation | 28–52 | 180–330 |
| Cold | Typical | 18–30 | 310–510 |
| Cold | Tight, well insulated | 12–22 | 420–770 |
| Very cold | Drafty, little insulation | 32–58 | 160–290 |
| Very cold | Typical | 22–38 | 240–420 |
| Very cold | Tight, well insulated | 16–28 | 330–580 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for GWH12AGC-D3DNA1A/O
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 12,000 Btu/h3.52 kWNR | 12,000 Btu/h3.52 kW |
| Heat output at 17°F full speed | 10,000 Btu/h2.93 kWNR | 10,000 Btu/h2.93 kW |
| Heat output at 5°F full speed | 9,200 Btu/h2.70 kWNR | 9,200 Btu/h2.70 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 77%NR | |
| COP at 5°F full speed | 1.93NR | 1.93 |
| HSPF2 Region IV | 9.0NR | 9.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 12,000 Btu/h3.52 kWNR | 12,000 Btu/h3.52 kW |
| EER2 at 95°F | 12.5NR | 12.5 |
| SEER2 cooling season | 25.0NR | 25.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | GWH12AGC-D3DN***/I | 3 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | Canada | Canada |
| Model string as certified | GWH12AGC-D3DNA1A/O | |
Pairings, by indoor-unit class
3 indoor units · 3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 3 indoor units
-
GWH12AFC-D3DN***/I (the pairing on screen) GREE 9,200 Btu/h2.70 kWat 5°F, full speed
-
GWH12AGC-D3DN***/I (the pairing on screen) GREE 9,200 Btu/h2.70 kWat 5°F, full speed
-
GWH12QC-D3DN***/I (the pairing on screen) GREE 9,200 Btu/h2.70 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| GWH12AFC-D3DN***/I (the pairing on screen) | GREE | 9,2002.70 | 12,0003.52 | 12,0003.52 | 77% | 1.93 | NC | 1 |
| GWH12AGC-D3DN***/I (the pairing on screen) | GREE | 9,2002.70 | 12,0003.52 | 12,0003.52 | 77% | 1.93 | Yes | 1 |
| GWH12QC-D3DN***/I (the pairing on screen) | GREE | 9,2002.70 | 12,0003.52 | 12,0003.52 | 77% | 1.93 | NC | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- GWH12AGC-D3DNA1A/O 3 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- GWH12AGC-D3DNA1A/O left the certified data on Oct 17, 2026.
- GWH12AGC-D3DNA1A/O changed its certified heat output at 17°F on 3 pairings from 7,700 Btu/h to 10,000 Btu/h in the certified data between March 2025 and May 2025.
- GWH12AGC-D3DNA1A/O was in the certified data by September 2024.
History and definitions
Other Muse models by nominal cooling size: GWH09ACD-D3DNA1A/O (9,000 Btu), GWH09AGCXD-D3DNA1A/O (9,000 Btu), GWH12AGCXD-D3DNA1A/O (12,000 Btu), GWH18YE-D3DNA1A/O (18,000 Btu).
Other Pular models by nominal cooling size: GWH09AGCXD-A3DNA1A/O (9,000 Btu), GWH09AGCXD-D3DNA1A/O (9,000 Btu), GWH09AGCXD-D6DNA4D/O (9,000 Btu), GWH09AUCXD-A6DNA1C/O (9,000 Btu), GWH12AGCXD-A3DNA1A/O (12,000 Btu), GWH12AGCXD-D3DNA1A/O (12,000 Btu), GWH12AGCXD-D6DNA4D/O (12,000 Btu), GWH12AGDXF-D6DNA2B/O (12,000 Btu); more models from this brand.
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 13, 2026
- Last listed
- Status
- Not in the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read