GWH18ATDXD-D6DNA4F/O
Gree · mini-split heat pump
GWH18ATDXD-D6DNA4F/O is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
17,0004.98NR
No 47°F rating for this pairing.
15,3004.48NR at 17°F
12,1003.55NR at 5°F
Btu/hkW, certified
1.85NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 17,000 Btu/h4.98 kW of heat at 47°F, 15,300 Btu/h4.48 kW at 17°F, and 12,100 Btu/h3.55 kW at 5°F, 71% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 1,900 Btu/h0.56 kW short of the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215224737 · listed by GREE · certified Jul 17, 2026 · 2 pairings share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 12,1003.55 kW | −15% | 1.85 | |
| 17°Ffull speed | 15,3004.48 kW | +3% | NR | |
| 47°Fnormal speed | 17,0004.98 kW | −6% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 12.0 in that test. SEER2 20.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.92kW
- Electrical input in the 95°F cooling test
- 1.50kW
- Seasonal average heating COP
- 2.49
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 12,100 Btu/h3.55 kWNR
- This unit at 5°F median across its pairings
- 12,100 Btu/h3.55 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 10% of them, at number 1,001 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Among 18,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 784th of 1,110 (tied); HSPF2, 1,074th of 1,114 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- MUZ-FX18NLHZ: The same 17,000 Btu/h rating at 47°F; 23,600 Btu/h at 5°F (this model: 12,100).
- DWA5-ACDC-18KR2(US): The same 17,000 Btu/h rating at 47°F; HSPF2 9.8 (this model: 8.5).
- 1U18AP2VHA: The same 17,000 Btu/h rating at 47°F; HSPF2 9.5 (this model: 8.5).
Closest models by heat at 5°F
- MXZ-2D20NLMitsubishi Electric · 12,600 Btu/h
- MWHD018S6-1PLennox · 12,500 Btu/h
- VPC018H4M-3PLennox · 12,300 Btu/h
- MOX230-17HFN8-M1LMDV · 12,000 Btu/h
- YN018GLFI22RPDPioneer · 11,900 Btu/h
- 38MHRCQ18AA3Bryant, Carrier + 3 more · 11,700 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 12,100 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 290–500 |
| Mild | Typical | 16–26 | 470–760 |
| Mild | Tight, well insulated | 10–18 | 670–1,210 |
| Cold | Drafty, little insulation | 28–52 | 230–430 |
| Cold | Typical | 18–30 | 400–670 |
| Cold | Tight, well insulated | 12–22 | 550–1,010 |
| Very cold | Drafty, little insulation | 32–58 | 210–380 |
| Very cold | Typical | 22–38 | 320–550 |
| Very cold | Tight, well insulated | 16–28 | 430–760 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for GWH18ATDXD-D6DNA4F/O
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 17,000 Btu/h4.98 kWNR | 17,000 Btu/h4.98 kW |
| Heat output at 17°F full speed | 15,300 Btu/h4.48 kWNR | 15,300 Btu/h4.48 kW |
| Heat output at 5°F full speed | 12,100 Btu/h3.55 kWNR | 12,100 Btu/h3.55 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 71%NR | |
| COP at 5°F full speed | 1.85NR | 1.85 |
| HSPF2 Region IV | 8.5NR | 8.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 12.0NR | 11.95–12.0 |
| SEER2 cooling season | 20.0NR | 20.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | GWH18ATDXD-D6DN***/I | 3 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | GWH18ATDXD-D6DNA4F/O | |
Pairings, by indoor-unit class
3 indoor units · 3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 3 indoor units
-
GWH18ATDXD-D6DN***/I (the pairing on screen) GREE 12,100 Btu/h3.55 kWat 5°F, full speed
-
GWH18AWDXD-D6DN***/I (the pairing on screen) GREE 12,100 Btu/h3.55 kWat 5°F, full speed
-
GWH18AZDXD-D6DN***/I (the pairing on screen) GREE 12,100 Btu/h3.55 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| GWH18ATDXD-D6DN***/I (the pairing on screen) | GREE | 12,1003.55 | 17,0004.98 | 18,0005.28 | 71% | 1.85 | Yes | 1 |
| GWH18AWDXD-D6DN***/I (the pairing on screen) | GREE | 12,1003.55 | 17,0004.98 | 18,0005.28 | 71% | 1.85 | Yes | 1 |
| GWH18AZDXD-D6DN***/I (the pairing on screen) | GREE | 12,1003.55 | 17,0004.98 | 18,0005.28 | 71% | 1.85 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- GWH18ATDXD-D6DNA4F/O 3 pairings
Variants of the same model number
21 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- CHM18HP230V1R32AOGree
- CHW18KR32-OWillis
- EHS-O18KBBEco AC
- GS18HP230V1ASOGree
- GWH18ATDXD-D6DNA1A/OGree
- KW18HQ19CDOKinghome
- KW18XQ19SDOKinghome
- LIV18HP230V1R32AOGree
- OCHX-H18A-OOuellet
- QVCH18*R32OQuébecVair
- TACCI7H4R18Tosot
- TAW20-18H1BTosot
- TS-18AGR32OD21Tosot
- TW18HC32A5DOTosot
- TW18HC32A5DOCTosot
- TW18WH19D6DOTosot
- TWH18AT19D6DOTosot
- TWH18ATD19R32A3DOTosot
- TWH18CD32AOTosot
- TWH18R32DOTosot
20 of 21 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
Other Charmo models by nominal cooling size: GWH09ATCXB-A3DNA1A/O (9,000 Btu), GWH09ATCXB-A6DNA1B/O (9,000 Btu), GWH09ATCXB-A6DNA1C/O (9,000 Btu), GWH09ATCXB-D3DNA1A/O (9,000 Btu), GWH09ATCXB-D6DNA1B/O (9,000 Btu), GWH09ATCXB-D6DNA1C/O (9,000 Btu), GWH12ATCXB-A3DNA1C/O (12,000 Btu), GWH12ATCXB-A6DNA1A/O (12,000 Btu); more models from this brand.
Other Shimo models by nominal cooling size: GWH18ATDXD-D6DNA1A/O (18,000 Btu), GWH24ATEXF-D6DNA1F/O (24,000 Btu), GWH36ATEXH-D6DNA1G/O (36,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 17, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read