GWHD(18)ND6MO
Gree · mini-split heat pump
GWHD(18)ND6MO is in the certified data as of Oct 2, 2026. GWHD(18)ND6MO changed its certified SEER2 on AHRI certificate 214931591 from 18.0 to 16.0 in the certified data between Oct 1, 2026 and Oct 2, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
18,0005.28NR
No 47°F rating for this pairing.
17,6005.16NR at 17°F
13,7004.02NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 18,000 Btu/h5.28 kW of heat at 47°F, 17,600 Btu/h5.16 kW at 17°F, and 13,700 Btu/h4.02 kW at 5°F, 76% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 300 Btu/h0.09 kW short of the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214931592 · listed by GREE · certified Oct 17, 2025 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 13,7004.02 kW | −4% | 1.80 | |
| 17°Ffull speed | 17,6005.16 kW | +19% | NR | |
| 47°Fnormal speed | 18,0005.28 kW | 0% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 11.8 in that test. SEER2 19.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.23kW
- Electrical input in the 95°F cooling test
- 1.53kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 13,700 Btu/h4.02 kWNR
- This unit at 5°F median across its pairings
- 13,700 Btu/h4.02 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 39% of them, at number 678 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- AO-18U3R25SSHisense · 13,700 Btu/h
- FSHSR18B3DFriedrich, Rheem + 1 more · 13,700 Btu/h
- GWHD(18)ND3NOGree · 13,700 Btu/h
- MUL18HP230V1R32AOGree · 13,700 Btu/h
- MUL19HP230V1R32AOGree · 13,700 Btu/h
- TMSCI7H4R18Tosot · 13,700 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for GWHD(18)ND6MO
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| Heat output at 17°F full speed | 17,600 Btu/h5.16 kWNR | 15,000–17,600 Btu/h4.40–5.16 kW |
| Heat output at 5°F full speed | 13,700 Btu/h4.02 kWNR | 13,600–13,800 Btu/h3.99–4.04 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 76%NR | |
| COP at 5°F full speed | 1.80NR | 1.80–2.00 |
| HSPF2 Region IV | 9.0NR | 8.1–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 16,000–18,000 Btu/h4.69–5.28 kW |
| EER2 at 95°F | 11.8NR | 11.0–12.0 |
| SEER2 cooling season | 19.0NR | 16.0–21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | GWHD(18)ND6MO | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) GREE 13,700 Btu/h4.02 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | GREE | 13,7004.02 | 18,0005.28 | 18,0005.28 | 76% | 1.86 | Yes | 3 |
Sold as, and units with identical certified values
Variants of the same model number
16 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH18-H2Air Max
- BXM2Z18UC0Blueridge
- DXH18FMK3IHAireForce · Airtemp · Gibson · Intertherm
- GMRSHC18AS2Classic
- GMRSHT18AS2TGM
- GS2M18HP230V1MOGree
- KM18X6OKinghome
- MHPC-D-018BMCAC Pro
- MUL18HPJ132OABoreal
- MZUHW18KR32-OWillis
- OFRM2X1-H18A-OOuellet
- QVMZ18*R32QuébecVair
- TM18H32MOTosot
- TM18R32MOTosot
- TMH18D32MOTosot
15 of 16 shown.
Other model numbers with identical certified values
15 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH18-H2identical certified values
- BXM2Z18UC0identical certified values
- GMRSHC18AS2identical certified values
- GMRSHT18AS2identical certified values
- GS2M18HP230V1MOidentical certified values
- KM18X6Oidentical certified values
- MHPC-D-018BMCidentical certified values
- MUL18HPJ132OAidentical certified values
- MZUHW18KR32-Oidentical certified values
- OFRM2X1-H18A-Oidentical certified values
- QVMZ18*R32identical certified values
- TM18H32MOidentical certified values
- TM18R32MOidentical certified values
- TMH18D32MOidentical certified values
14 of 15 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- GWHD(18)ND6MO changed its certified SEER2 on AHRI certificate 214931591 from 18.0 to 16.0 in the certified data between Oct 1, 2026 and Oct 2, 2026.
- GWHD(18)ND6MO changed its certified EER2 on AHRI certificate 214931591 from 11.7 to 11.0 in the certified data between Oct 1, 2026 and Oct 2, 2026.
- GWHD(18)ND6MO changed its certified cooling capacity at 95°F on AHRI certificate 214931591 from 18,000 Btu/h to 16,000 Btu/h in the certified data between Oct 1, 2026 and Oct 2, 2026.
- GWHD(18)ND6MO changed its certified heat output at 17°F on AHRI certificate 214931591 from 17,600 Btu/h to 15,000 Btu/h in the certified data between Oct 1, 2026 and Oct 2, 2026.
- GWHD(18)ND6MO changed its certified heat output at 17°F on 3 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 3.
- GWHD(18)ND6MO changed its certified heat output at 17°F on 3 pairings in the certified data between March 2025 and May 2025. The new figure is higher on all 3.
- GWHD(18)ND6MO changed its certified HSPF2 on AHRI certificate 214931591 from 8.0 to 8.1 in the certified data between September 2024 and November 2024.
- GWHD(18)ND6MO was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Oct 17, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read