GWHD(60)ND6MO
Gree · mini-split heat pump
GWHD(60)ND6MO is in the certified data as of Sep 19, 2026.
- 54,000 Btu (4.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
55,00016.12NR
No 47°F rating for this pairing.
40,00011.72NR at 17°F
32,0009.38NR at 5°F
Btu/hkW, certified
2.20NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 55,000 Btu/h16.12 kW of heat at 47°F, 40,000 Btu/h11.72 kW at 17°F, and 32,000 Btu/h9.38 kW at 5°F, 58% of its 47°F rating. It delivers 55,000 Btu/h16.12 kW of cooling at 95°F. At 5°F that is 15,500 Btu/h4.54 kW short of the example heating load of 47,500 Btu/h13.92 kW; at 95°F it is 31,000 Btu/h9.09 kW above the example cooling load of 24,000 Btu/h7.03 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 2,000 sq ft where winters reach 5°F: heating runs from 47,500 Btu/h13.92 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 24,000 Btu/h7.03 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218083085 · listed by GREE · certified Feb 11, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 32,0009.38 kW | −33% | 2.20 | |
| 17°Ffull speed | 40,00011.72 kW | −2% | NR | |
| 47°Fnormal speed | 55,00016.12 kW | 0% | NR | |
| 95°Fcooling, full load | 55,00016.12 kW | — | NR |
EER2 11.8 in that test. SEER2 20.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.26kW
- Electrical input in the 95°F cooling test
- 4.66kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 54,000 Btu heat pumps
4.5-ton mini-split models
- This pairing at 5°F
- 32,000 Btu/h9.38 kWNR
- This unit at 5°F median across its pairings
- 32,000 Btu/h9.38 kW
- Median of 4.5-ton mini-split models at 5°F
- 47,500 Btu/h13.92 kW
- Models in this group
- 115
This unit is above 0% of them, at number 115 of 115 by heat at 5°F. The middle half of the group runs 46,000 to 53,000 Btu/h.
Closest models by heat at 5°F
- BMM55HHCBlueridge · 45,500 Btu/h
- URHT-55FM6N4VKIN · 42,000 Btu/h
- YN060GLSI24M6GPioneer · 41,000 Btu/h
- KUSUB601ALG · 38,500 Btu/h
- TM60D6MOTosot · 36,400 Btu/h
- MUL60HP230V1R32AOGree · 32,000 Btu/h
Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for GWHD(60)ND6MO
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 55,000 Btu/h16.12 kWNR | 55,000 Btu/h16.12 kW |
| Heat output at 17°F full speed | 40,000 Btu/h11.72 kWNR | 40,000–41,000 Btu/h11.72–12.02 kW |
| Heat output at 5°F full speed | 32,000 Btu/h9.38 kWNR | 31,000–36,400 Btu/h9.09–10.67 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 58%NR | |
| COP at 5°F full speed | 2.20NR | 1.90–2.30 |
| HSPF2 Region IV | 9.0NR | 8.0–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 55,000 Btu/h16.12 kWNR | 55,000 Btu/h16.12 kW |
| EER2 at 95°F | 11.8NR | 11.65–11.8 |
| SEER2 cooling season | 20.0NR | 19.0–21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | GWHD(60)ND6MO | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) GREE 32,000 Btu/h9.38 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | GREE | 32,0009.38 | 55,00016.12 | 55,00016.12 | 58% | 2.20 | NC | 3 |
Sold as, and units with identical certified values
Variants of the same model number
10 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH60-H2Air Max
- BXM2Z55UC0Blueridge
- GS6M60HP230V1MOGree
- KM60X6OKinghome
- TGWHD-60NDTosot
- TM60R32HMOTosot
- TM60WH21MOTosot
- TMH60D32MOTosot
- TMSCI7H4R60Tosot
9 of 10 shown.
Other model numbers with identical certified values
10 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH60-H2identical certified values
- BXM2Z55UC0identical certified values
- GS6M60HP230V1MOidentical certified values
- KM60X6Oidentical certified values
- TGWHD-60NDidentical certified values
- TM60R32HMOidentical certified values
- TM60WH21MOidentical certified values
- TMH60D32MOidentical certified values
- TMSCI7H4R60identical certified values
9 of 10 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Feb 11, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read