HSA1936V1-**A

HSA1936V1-**A is in the certified data.

Its certified full-speed heating output at 5°F is 13,700–17,000 Btu/h, 45–71% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Century and Comfort-Aire · central heat pump

All 56 certified Century models · All 83 certified Comfort-Aire models

HSA1936V1-**A is in the certified data as of Sep 19, 2026. HSA1936V1-**A changed its certified heat output at 47°F on 4 pairings in the certified data between August 2025 and September 2026. The new figure is lower on all 4.

142 certified pairings with 64 different figures. See all

Certified heating and cooling

Heating at 47°F

23,600

15,800 at 17°F

15,500 at 5°F

Btu/h, certified

1.88 COP at 5°F

Cooling at 95°F

24,000

Btu/h, certified

EER2 12.6 at 95°F

SEER2 18.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for HSA1936V1-**A, by outdoor temperature Heating: 15,500 Btu/h at 5°F, 15,800 Btu/h at 17°F, 23,600 Btu/h at 47°F. Cooling: 24,000 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 15,500 5°F 15,800 17°F 23,600 47°F 24,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 23,600 Btu/h of heat at 47°F, 15,800 Btu/h at 17°F, and 15,500 Btu/h at 5°F, 66% of its 47°F rating. It delivers 24,000 Btu/h of cooling at 95°F. At 5°F that is 3,500 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 14,500 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217504015 · listed by Century · certified Jul 3, 2025 · 2 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 49 programs in 28 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (1), Delaware (2), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Michigan (2), Minnesota (2), Mississippi (2), Nevada (1), New Hampshire (1), New Jersey (7), New York (4), North Carolina (1), Oregon (2), Pennsylvania (4), South Carolina (1), Tennessee (1), Texas (3), Utah (1), Vermont (3), Washington (2), Wisconsin (1), Newfoundland and Labrador (1).

All 49 programs by state and province

Alabama

Arizona

California

Colorado

Delaware

Idaho

Illinois

Kansas

Kentucky

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

Newfoundland and Labrador

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 15,5004.54 kW −18% 1.88
17°Ffull speed 15,8004.63 kW −18% NR
47°Fnormal speed 23,6006.92 kW −2% NR
95°Fcooling, full load 24,0007.03 kW — NR

EER2 12.6 in that test. SEER2 18.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.42kW
Electrical input in the 95°F cooling test
1.90kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
15,500 Btu/h
This unit at 5°F median across its pairings
15,500 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 24% of them, at number 427 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 24,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 436th of 565; HSPF2, 423rd of 578 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • MDPH18024D: The same 24,000 Btu/h rating at 47°F; 29,000 Btu/h at 5°F (this model: 15,500).
  • AC024BXUPCH: The same 24,000 Btu/h rating at 47°F; 26,000 Btu/h at 5°F (this model: 15,500).
  • FRP18AZ24AJVC: The same 24,000 Btu/h rating at 47°F; 24,800 Btu/h at 5°F (this model: 15,500).

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 15,500 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42370–650
MildTypical16–26600–970
MildTight, well insulated10–18860–1,550
ColdDrafty, little insulation28–52300–550
ColdTypical18–30520–860
ColdTight, well insulated12–22700–1,290
Very coldDrafty, little insulation32–58270–480
Very coldTypical22–38410–700
Very coldTight, well insulated16–28550–970

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for HSA1936V1-**A

142 pairings · 142 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for HSA1936V1-**A
This pairingAll pairings
Heating
Heat output at 47°F normal speed 23,600 Btu/h 22,800–36,000 Btu/h
Heat output at 17°F full speed 15,800 Btu/h 14,600–21,600 Btu/h
Heat output at 5°F full speed 15,500 Btu/h 13,700–17,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 66%
COP at 5°F full speed 1.88 1.48–2.12
HSPF2 Region IV 8.5 7.8–8.5
Cooling
Cooling capacity at 95°F full-load test 24,000 Btu/h 21,600–35,200 Btu/h
EER2 at 95°F 12.6 11.0–13.2
SEER2 cooling season 18.0 15.2–20.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit 7E[C,U]36BX-**+TDR 19 indoor units
FurnaceGUH96C045B3MP 25 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified HSA1936V1-**A

Across 142 certified pairings with 19 indoor models: heat at 5°F 13,700 Btu/h with 7E[C,U]30AX-**+TDR to 17,000 Btu/h with 7E[C,U]24AX-**+TDR; HSPF2 7.8 with 7EH30AX-**+TDR to 8.5 with 7EH30BX-**+TDR; SEER2 15.2 with 7EH30BX-**+TDR to 20.0 with 7E[C,U]24BX-**+TDR. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

19 indoor units · 142 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 4 indoor units

  1. 7E[C,U]36BX-**+TDR (the pairing on screen) brand not stated 14,900 Btu/hat 5°F, full speed

    18 pairings, 9 with a furnace · 47°F 32,000 Btu/h · 95°F cooling 34,400 Btu/h · Cold output 46% · COP 1.92

  2. 7EH36CX-**+TDR brand not stated 16,350 Btu/hat 5°F, full speed

    16 pairings, 8 with a furnace · 47°F 32,600 Btu/h · 95°F cooling 34,400 Btu/h · Cold output 50% · COP 2.08

  3. 7ED30/36CX-**+TDR brand not stated 16,400 Btu/hat 5°F, full speed

    6 pairings, 3 with a furnace · 47°F 35,000 Btu/h · 95°F cooling 34,600 Btu/h · Cold output 47% · COP 2.12

  4. 7EH30AX-**+TDR brand not stated 14,900 Btu/hat 5°F, full speed

    6 pairings, 3 with a furnace · 47°F 23,800 Btu/h · 95°F cooling 23,200 Btu/h · Cold output 63% · COP 1.50

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
7E[C,U]36BX-**+TDR (the pairing on screen) — 14,900 32,000 34,400 46% 1.92 NC 18
7EH36CX-**+TDR — 16,350 32,600 34,400 50% 2.08 NC 16
7ED30/36CX-**+TDR — 16,400 35,000 34,600 47% 2.12 NC 6
7EH30AX-**+TDR — 14,900 23,800 23,200 63% 1.50 NC 6

Air handler · 6 indoor units

  1. 7EH30BX-**+TDR brand not stated 15,100 Btu/hat 5°F, full speed

    16 pairings, 7 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 22,400 Btu/h · Cold output 63% · COP 1.90

  2. 7E[C,U]24BX-**+TDR brand not stated 16,500 Btu/hat 5°F, full speed

    16 pairings, 7 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 23,900 Btu/h · Cold output 69% · COP 2.02

  3. 7E[C,U]30BX-**+TDR brand not stated 14,000 Btu/hat 5°F, full speed

    16 pairings, 7 with a furnace · 47°F 23,800 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 59% · COP 1.88

  4. 7E[C,U]24AX-**+TDR brand not stated 16,500 Btu/hat 5°F, full speed

    10 pairings, 4 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 69% · COP 2.02

  5. 7E[C,U]30AX-**+TDR brand not stated 14,000 Btu/hat 5°F, full speed

    10 pairings, 4 with a furnace · 47°F 23,800 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 59% · COP 1.88

  6. 7E[C,U]36AX-**+TDR brand not stated 14,900 Btu/hat 5°F, full speed

    10 pairings, 4 with a furnace · 47°F 32,200 Btu/h · 95°F cooling 34,400 Btu/h · Cold output 46% · COP 1.90

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
7EH30BX-**+TDR — 15,100 24,000 22,400 63% 1.90 NC 16
7E[C,U]24BX-**+TDR — 16,500 24,000 23,900 69% 2.02 NC 16
7E[C,U]30BX-**+TDR — 14,000 23,800 24,000 59% 1.88 NC 16
7E[C,U]24AX-**+TDR — 16,500 24,000 23,600 69% 2.02 NC 10
7E[C,U]30AX-**+TDR — 14,000 23,800 23,800 59% 1.88 NC 10
7E[C,U]36AX-**+TDR — 14,900 32,200 34,400 46% 1.90 NC 10

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 19 indoor units All 142 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Other brands that list these model numbers

Model number as listed

Product history

  • HSA1936V1-**A changed its certified heat output at 47°F on 4 pairings in the certified data between August 2025 and September 2026. The new figure is lower on all 4.
  • HSA1936V1-**A first appeared in the certified data between June 2025 and August 2025.

History and definitions

Other HSA19 Series models by nominal cooling size: HSA1960V1-**A (48,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Jul 3, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read