LEO12K30S25V220H1
LEO12K30S25V220H1 is in the certified data.
Its certified full-speed heating output at 5°F is 12,000–18,600 Btu/h3.52–5.45 kW, 74–100% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
LEO Air · mini-split heat pump
All 12 certified LEO Air models
LEO12K30S25V220H1 is in the certified data as of Oct 22, 2026.
- 12,000 Btu (1-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
12,0003.52NR
No 47°F rating for this pairing.
14,0004.10NR at 17°F
12,0003.52NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 12,000 Btu/h3.52 kW of heat at 47°F, 14,000 Btu/h4.10 kW at 17°F, and 12,000 Btu/h3.52 kW at 5°F, 100% of its 47°F rating. It delivers 12,000 Btu/h3.52 kW of cooling at 95°F. At 5°F that is 3,000 Btu/h0.88 kW above the example heating load of 9,000 Btu/h2.64 kW; at 95°F it is 7,000 Btu/h2.05 kW above the example cooling load of 5,000 Btu/h1.47 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 400 sq ft where winters reach 5°F: heating runs from 9,000 Btu/h2.64 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,000 Btu/h1.47 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218736943 · listed by LEO AIR · certified Oct 20, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 11 programs in 7 states, provinces, or territories:British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).
All 11 programs by state and province
British Columbia
- CleanBC Energy Savings Program · BC Hydro · FortisBC · municipal utilities
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Manitoba
New Brunswick
Newfoundland and Labrador
Nova Scotia
- Home Energy Assessment: Heat Pump Rebates · Nova Scotia Power
- Moderate Income Rebate · Nova Scotia Power
Ontario
Yukon
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 12,0003.52 kW | +30% | 1.80 | |
| 17°Ffull speed | 14,0004.10 kW | +43% | NR | |
| 47°Fnormal speed | 12,0003.52 kW | 0% | NR | |
| 95°Fcooling, full load | 12,0003.52 kW | — | NR |
EER2 14.0 in that test. SEER2 25.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.95kW
- Electrical input in the 95°F cooling test
- 0.86kW
- Seasonal average heating COP
- 3.08
These exclude backup resistance heat.
How it compares with other 12,000 Btu heat pumps
1-ton mini-split models
- This pairing at 5°F
- 12,000 Btu/h3.52 kWNR
- This unit at 5°F median across its pairings
- 12,000 Btu/h3.52 kW
- Median of 1-ton mini-split models at 5°F
- 9,200 Btu/h2.70 kW
- Models in this group
- 888
This unit is above 83% of them, at number 154 of 888 by heat at 5°F. The middle half of the group runs 8,400 to 11,300 Btu/h.
Among 12,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 275th of 887; HSPF2, 341st of 895 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- BM12YDIY22C: The same 12,000 Btu/h rating at 47°F; 46,000 Btu/h at 5°F (this model: 12,000).
- DIY-12-HP-C-115C: The same 12,000 Btu/h rating at 47°F; 6,400 Btu/h at 5°F (this model: 12,000).
- YN012AMFI22RPE: The same 12,000 Btu/h rating at 47°F; 6,500 Btu/h at 5°F (this model: 12,000).
Closest models by heat at 5°F
- FPHFR12A3DFriedrich, Rheem + 1 more · 12,000 Btu/h
- GWH12YD-D3DNA1A/OGree · 12,000 Btu/h
- H12SUH25XGCTCL · 12,000 Btu/h
- MLB012S4S-1PLennox · 12,000 Btu/h
- MSH-12HD-AMulti MFG · 12,000 Btu/h
- O-HH-12-HP-C-230AMRCOOL · 12,000 Btu/h
Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 12,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 290–500 |
| Mild | Typical | 16–26 | 460–750 |
| Mild | Tight, well insulated | 10–18 | 670–1,200 |
| Cold | Drafty, little insulation | 28–52 | 230–430 |
| Cold | Typical | 18–30 | 400–670 |
| Cold | Tight, well insulated | 12–22 | 550–1,000 |
| Very cold | Drafty, little insulation | 32–58 | 210–380 |
| Very cold | Typical | 22–38 | 320–550 |
| Very cold | Tight, well insulated | 16–28 | 430–750 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for LEO12K30S25V220H1
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 12,000 Btu/h3.52 kWNR | 12,000–25,000 Btu/h3.52–7.33 kW |
| Heat output at 17°F full speed | 14,000 Btu/h4.10 kWNR | 14,000–21,000 Btu/h4.10–6.15 kW |
| Heat output at 5°F full speed | 12,000 Btu/h3.52 kWNR | 12,000–18,600 Btu/h3.52–5.45 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 100%NR | |
| COP at 5°F full speed | 1.80NR | 1.80 |
| HSPF2 Region IV | 10.5NR | 9.5–10.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 12,000 Btu/h3.52 kWNR | 12,000–23,000 Btu/h3.52–6.74 kW |
| EER2 at 95°F | 14.0NR | 11.7–14.0 |
| SEER2 cooling season | 25.0NR | 23.0–25.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | LEO12K30S25V220H1 | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | Canada | Canada |
| Model string as certified | LEO12K30S25V220H1 | |
Across 2 certified pairings with 1 indoor model: heat at 5°F 12,000 Btu/h with LEO12K30S25V220H1 to 18,600 Btu/h with LEO12K30S25V220H1; HSPF2 9.5 with LEO12K30S25V220H1 to 10.5 with LEO12K30S25V220H1; SEER2 23.0 with LEO12K30S25V220H1 to 25.0 with LEO12K30S25V220H1. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.
Pairings, by indoor-unit class
1 indoor unit · 2 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
LEO12K30S25V220H1 (the pairing on screen) LEO AIR 15,300 Btu/h4.48 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| LEO12K30S25V220H1 (the pairing on screen) | LEO AIR | 15,3004.48 | 18,5005.42 | 17,5005.13 | 87% | 1.80 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- LEO12K30S25V220H1 1 pairing
- LEO12K30S25V220H1* 1 pairing
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- LEO12K30S25V220H1 first appeared in the certified data between Oct 21, 2026 and Oct 22, 2026.
History and definitions
Other TPRO models by nominal cooling size: LEO9K30S25V220H1 (9,000 Btu), LEO18K30S25V220H1 (18,000 Btu), LEO24K30S25V220H1 (24,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Oct 20, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read