LUU180HV
LUU180HV is in the certified data.
Its certified full-speed heating output at 5°F is 16,000–16,200 Btu/h4.69–4.75 kW, 80–88% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
LG · mini-split heat pump
LUU180HV is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
18,5005.42NR
No 47°F rating for this pairing.
12,7003.72NR at 17°F
16,2004.75NR at 5°F
Btu/hkW, certified
1.85NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 18,500 Btu/h5.42 kW of heat at 47°F, 12,700 Btu/h3.72 kW at 17°F, and 16,200 Btu/h4.75 kW at 5°F, 88% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 2,200 Btu/h0.64 kW above the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 211234504 · listed by LG · certified Mar 9, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 11 programs in 7 states, provinces, or territories:British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).
All 11 programs by state and province
British Columbia
- CleanBC Energy Savings Program · BC Hydro · FortisBC · municipal utilities
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Manitoba
New Brunswick
Newfoundland and Labrador
Nova Scotia
- Home Energy Assessment: Heat Pump Rebates · Nova Scotia Power
- Moderate Income Rebate · Nova Scotia Power
Ontario
Yukon
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 16,2004.75 kW | +14% | 1.85 | |
| 17°Ffull speed | 12,7003.72 kW | −14% | NR | |
| 47°Fnormal speed | 18,5005.42 kW | +3% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 12.5 in that test. SEER2 20.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.57kW
- Electrical input in the 95°F cooling test
- 1.44kW
- Seasonal average heating COP
- 2.84
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 16,200 Btu/h4.75 kWNR
- This unit at 5°F median across its pairings
- 16,200 Btu/h4.75 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 61% of them, at number 438 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Among 18,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 488th of 1,110; HSPF2, 672nd of 1,114 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- 37MPRAQ18AA3: The same 20,000 Btu/h rating at 47°F; 22,600 Btu/h at 5°F (this model: 16,200).
- DLCPRBH18AAK: The same 20,000 Btu/h rating at 47°F; 24,000 Btu/h at 5°F (this model: 16,200).
- NTXSKS18A112: The same 20,000 Btu/h rating at 47°F; 10,300 Btu/h at 5°F (this model: 16,200).
Closest models by heat at 5°F
- DEA18HOS28230E8Elios · 16,400 Btu/h
- MSH183E23MCAAFranklin and Goodman · 16,400 Btu/h
- NH25-18H-ONapoleon · 16,400 Btu/h
- MXZ-2C20NAHZ4Mitsubishi Electric · 16,100 Btu/h
- AOODU-1D2SAokol · 16,000 Btu/h
- MMPD018S6S-1PLennox · 16,000 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 16,200 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 390–680 |
| Mild | Typical | 16–26 | 620–1,010 |
| Mild | Tight, well insulated | 10–18 | 900–1,620 |
| Cold | Drafty, little insulation | 28–52 | 310–580 |
| Cold | Typical | 18–30 | 540–900 |
| Cold | Tight, well insulated | 12–22 | 740–1,350 |
| Very cold | Drafty, little insulation | 32–58 | 280–510 |
| Very cold | Typical | 22–38 | 430–740 |
| Very cold | Tight, well insulated | 16–28 | 580–1,010 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for LUU180HV
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 18,500 Btu/h5.42 kWNR | 18,500–20,000 Btu/h5.42–5.86 kW |
| Heat output at 17°F full speed | 12,700 Btu/h3.72 kWNR | 12,400–13,000 Btu/h3.63–3.81 kW |
| Heat output at 5°F full speed | 16,200 Btu/h4.75 kWNR | 16,000–16,200 Btu/h4.69–4.75 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 88%NR | |
| COP at 5°F full speed | 1.85NR | 1.85–2.02 |
| HSPF2 Region IV | 9.7NR | 9.3–9.9 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 12.5NR | 12.3–12.6 |
| SEER2 cooling season | 20.5NR | 17.25–20.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | LCN188HV4 | 3 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | Canada | Canada |
| Model string as certified | LUU180HV | |
Across 3 certified pairings with 3 indoor models: heat at 5°F 16,000 Btu/h with LHN188HV1 to 16,200 Btu/h with LCN188HV4; HSPF2 9.25 with LVN181HV4 to 9.9 with LHN188HV1; SEER2 17.25 with LVN181HV4 to 20.5 with LCN188HV4. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.
Pairings, by indoor-unit class
3 indoor units · 3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 3 indoor units
-
LCN188HV4 (the pairing on screen) LG 16,200 Btu/h4.75 kWat 5°F, full speed
-
LHN188HV1 (the pairing on screen) LG 16,000 Btu/h4.69 kWat 5°F, full speed
-
LVN181HV4 (the pairing on screen) LG 16,200 Btu/h4.75 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| LCN188HV4 (the pairing on screen) | LG | 16,2004.75 | 18,5005.42 | 18,0005.28 | 88% | 1.85 | Yes | 1 |
| LHN188HV1 (the pairing on screen) | LG | 16,0004.69 | 20,0005.86 | 18,0005.28 | 80% | 1.90 | Yes | 1 |
| LVN181HV4 (the pairing on screen) | LG | 16,2004.75 | 20,0005.86 | 18,0005.28 | 81% | 2.02 | Yes | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 9, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read