LUU360HV
LUU360HV is in the certified data.
Its certified full-speed heating output at 5°F is 32,600–35,000 Btu/h9.55–10.26 kW, 84–96% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
LG · mini-split heat pump
LUU360HV is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
40,00011.72NR
No 47°F rating for this pairing.
24,0007.03NR at 17°F
33,6009.85NR at 5°F
Btu/hkW, certified
1.87NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 40,000 Btu/h11.72 kW of heat at 47°F, 24,000 Btu/h7.03 kW at 17°F, and 33,600 Btu/h9.85 kW at 5°F, 84% of its 47°F rating. It delivers 36,000 Btu/h10.55 kW of cooling at 95°F. At 5°F that is 2,600 Btu/h0.76 kW above the example heating load of 31,000 Btu/h9.09 kW; at 95°F it is 20,500 Btu/h6.01 kW above the example cooling load of 15,500 Btu/h4.54 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,300 sq ft where winters reach 5°F: heating runs from 31,000 Btu/h9.09 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 15,500 Btu/h4.54 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 211234509 · listed by LG · certified Mar 9, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 11 programs in 7 states, provinces, or territories:British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).
All 11 programs by state and province
British Columbia
- CleanBC Energy Savings Program · BC Hydro · FortisBC · municipal utilities
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Manitoba
New Brunswick
Newfoundland and Labrador
Nova Scotia
- Home Energy Assessment: Heat Pump Rebates · Nova Scotia Power
- Moderate Income Rebate · Nova Scotia Power
Ontario
Yukon
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 33,6009.85 kW | +8% | 1.87 | |
| 17°Ffull speed | 24,0007.03 kW | −19% | NR | |
| 47°Fnormal speed | 40,00011.72 kW | +8% | NR | |
| 95°Fcooling, full load | 36,00010.55 kW | — | NR |
EER2 11.85 in that test. SEER2 18.85 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.27kW
- Electrical input in the 95°F cooling test
- 3.04kW
- Seasonal average heating COP
- 2.70
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton mini-split models
- This pairing at 5°F
- 33,600 Btu/h9.85 kWNR
- This unit at 5°F median across its pairings
- 33,600 Btu/h9.85 kW
- Median of 3-ton mini-split models at 5°F
- 31,000 Btu/h9.09 kW
- Models in this group
- 553
This unit is above 60% of them, at number 220 of 553 by heat at 5°F. The middle half of the group runs 26,000 to 36,000 Btu/h.
Among 36,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 241st of 551; HSPF2, 413th of 553 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- PUZ-A36NKA: The same 40,000 Btu/h rating at 47°F; 15,500 Btu/h at 5°F (this model: 33,600).
- PUZ-AK36NL: The same 40,000 Btu/h rating at 47°F; 20,000 Btu/h at 5°F (this model: 33,600).
- VPC036H4M-3PS: The same 40,000 Btu/h rating at 47°F; 21,000 Btu/h at 5°F (this model: 33,600).
Closest models by heat at 5°F
- 37VMB036HDS3-1Bryant, Carrier + 1 more · 34,000 Btu/h
- GS4M36HP230V1MOGree · 34,000 Btu/h
- LUU360HHVLG · 33,800 Btu/h
- ACIQ-36Z-E-HH-M4ACiQ · 33,400 Btu/h
- AM4-H36/2DR3BAUX · 33,000 Btu/h
- AOUG36LMAS1Fujitsu · 32,800 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 33,600 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 800–1,400 |
| Mild | Typical | 16–26 | 1,290–2,100 |
| Mild | Tight, well insulated | 10–18 | 1,870–3,360 |
| Cold | Drafty, little insulation | 28–52 | 650–1,200 |
| Cold | Typical | 18–30 | 1,120–1,870 |
| Cold | Tight, well insulated | 12–22 | 1,530–2,800 |
| Very cold | Drafty, little insulation | 32–58 | 580–1,050 |
| Very cold | Typical | 22–38 | 880–1,530 |
| Very cold | Tight, well insulated | 16–28 | 1,200–2,100 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for LUU360HV
4 pairings · 4 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 40,000 Btu/h11.72 kWNR | 34,000–40,000 Btu/h9.96–11.72 kW |
| Heat output at 17°F full speed | 24,000 Btu/h7.03 kWNR | 21,000–24,000 Btu/h6.15–7.03 kW |
| Heat output at 5°F full speed | 33,600 Btu/h9.85 kWNR | 32,600–35,000 Btu/h9.55–10.26 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 84%NR | |
| COP at 5°F full speed | 1.87NR | 1.80–2.10 |
| HSPF2 Region IV | 9.2NR | 9.0–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 36,000 Btu/h10.55 kWNR | 30,000–36,000 Btu/h8.79–10.55 kW |
| EER2 at 95°F | 11.85NR | 11.85–12.8 |
| SEER2 cooling season | 18.85NR | 16.25–21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | LHN368HV | 4 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | Canada | Canada |
| Model string as certified | LUU360HV | |
Across 4 certified pairings with 4 indoor models: heat at 5°F 32,600 Btu/h with LVN300HCV to 35,000 Btu/h with LCN369HV; HSPF2 8.95 with LVN361HV4 to 10.0 with LCN369HV; SEER2 16.25 with LVN361HV4 to 21.0 with LCN369HV. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.
Pairings, by indoor-unit class
4 indoor units · 4 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 4 indoor units
-
LCN369HV (the pairing on screen) LG 35,000 Btu/h10.26 kWat 5°F, full speed
-
LHN368HV (the pairing on screen) LG 33,600 Btu/h9.85 kWat 5°F, full speed
-
LVN300HCV (the pairing on screen) LG 32,600 Btu/h9.55 kWat 5°F, full speed
-
LVN361HV4 (the pairing on screen) LG 33,800 Btu/h9.91 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| LCN369HV (the pairing on screen) | LG | 35,00010.26 | 40,00011.72 | 36,00010.55 | 88% | 2.10 | Yes | 1 |
| LHN368HV (the pairing on screen) | LG | 33,6009.85 | 40,00011.72 | 36,00010.55 | 84% | 1.87 | Yes | 1 |
| LVN300HCV (the pairing on screen) | LG | 32,6009.55 | 34,0009.96 | 30,0008.79 | 96% | 1.80 | Yes | 1 |
| LVN361HV4 (the pairing on screen) | LG | 33,8009.91 | 40,00011.72 | 33,2009.73 | 85% | 1.81 | Yes | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 9, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read