LUU420HV
LUU420HV is in the certified data.
Its certified full-speed heating output at 5°F is 38,500–39,000 Btu/h11.28–11.43 kW, 82–83% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
LG · mini-split heat pump
LUU420HV is in the certified data as of Sep 19, 2026.
- 42,000 Btu (3.5-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
47,00013.77NR
No 47°F rating for this pairing.
29,2008.56NR at 17°F
38,50011.28NR at 5°F
Btu/hkW, certified
1.88NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 47,000 Btu/h13.77 kW of heat at 47°F, 29,200 Btu/h8.56 kW at 17°F, and 38,500 Btu/h11.28 kW at 5°F, 82% of its 47°F rating. It delivers 42,000 Btu/h12.31 kW of cooling at 95°F. At 5°F that is 2,500 Btu/h0.73 kW above the example heating load of 36,000 Btu/h10.55 kW; at 95°F it is 24,000 Btu/h7.03 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,000 Btu/h10.55 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 211234515 · listed by LG · certified Mar 9, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 11 programs in 7 states, provinces, or territories:British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).
All 11 programs by state and province
British Columbia
- CleanBC Energy Savings Program · BC Hydro · FortisBC · municipal utilities
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Manitoba
New Brunswick
Newfoundland and Labrador
Nova Scotia
- Home Energy Assessment: Heat Pump Rebates · Nova Scotia Power
- Moderate Income Rebate · Nova Scotia Power
Ontario
Yukon
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 38,50011.28 kW | +7% | 1.88 | |
| 17°Ffull speed | 29,2008.56 kW | −9% | NR | |
| 47°Fnormal speed | 47,00013.77 kW | +7% | NR | |
| 95°Fcooling, full load | 42,00012.31 kW | — | NR |
EER2 10.75 in that test. SEER2 17.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 6.00kW
- Electrical input in the 95°F cooling test
- 3.91kW
- Seasonal average heating COP
- 2.74
These exclude backup resistance heat.
How it compares with other 42,000 Btu heat pumps
3.5-ton mini-split models
- This pairing at 5°F
- 38,500 Btu/h11.28 kWNR
- This unit at 5°F median across its pairings
- 38,500 Btu/h11.28 kW
- Median of 3.5-ton mini-split models at 5°F
- 36,000 Btu/h10.55 kW
- Models in this group
- 161
This unit is above 84% of them, at number 26 of 161 by heat at 5°F. The middle half of the group runs 33,000 to 37,000 Btu/h.
Among 42,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 62nd of 161; HSPF2, 66th of 161. Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- AOUH42KUAH1: The same 47,000 Btu/h rating at 47°F; 48,000 Btu/h at 5°F (this model: 38,500).
- AOUH42KUAS1: The same 47,000 Btu/h rating at 47°F; HSPF2 10.3 (this model: 9.7).
- MMPD048S6M-1P: 47,500 Btu/h at 47°F (this model: 47,000); 31,200 Btu/h at 5°F (this model: 38,500).
Closest models by heat at 5°F
- LUU601HVLG · 40,500 Btu/h
- LUU420HHVLG · 40,000 Btu/h
- YRAMX42N5HBAYork · 39,000 Btu/h
- EMH-5O42KBBEco AC · 37,800 Btu/h
- AOUH42KUAS1Fujitsu · 37,000 Btu/h
- CU - 6YM48CBUCPanasonic · 37,000 Btu/h
Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 38,500 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 920–1,600 |
| Mild | Typical | 16–26 | 1,480–2,410 |
| Mild | Tight, well insulated | 10–18 | 2,140–3,850 |
| Cold | Drafty, little insulation | 28–52 | 740–1,380 |
| Cold | Typical | 18–30 | 1,280–2,140 |
| Cold | Tight, well insulated | 12–22 | 1,750–3,210 |
| Very cold | Drafty, little insulation | 32–58 | 660–1,200 |
| Very cold | Typical | 22–38 | 1,010–1,750 |
| Very cold | Tight, well insulated | 16–28 | 1,380–2,410 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for LUU420HV
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 47,000 Btu/h13.77 kWNR | 47,000 Btu/h13.77 kW |
| Heat output at 17°F full speed | 29,200 Btu/h8.56 kWNR | 28,000–29,200 Btu/h8.21–8.56 kW |
| Heat output at 5°F full speed | 38,500 Btu/h11.28 kWNR | 38,500–39,000 Btu/h11.28–11.43 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 82%NR | |
| COP at 5°F full speed | 1.88NR | 1.88–1.96 |
| HSPF2 Region IV | 9.4NR | 9.4–10.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 42,000 Btu/h12.31 kWNR | 42,000 Btu/h12.31 kW |
| EER2 at 95°F | 10.75NR | 10.45–10.75 |
| SEER2 cooling season | 17.2NR | 17.2–19.3 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | LVN420HV | 2 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | Canada | Canada |
| Model string as certified | LUU420HV | |
Across 2 certified pairings with 2 indoor models: heat at 5°F 38,500 Btu/h with LVN420HV to 39,000 Btu/h with LCN429HV; HSPF2 9.35 with LVN420HV to 10.05 with LCN429HV; SEER2 17.2 with LVN420HV to 19.3 with LCN429HV. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.
Pairings, by indoor-unit class
2 indoor units · 2 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 2 indoor units
-
LCN429HV (the pairing on screen) LG 39,000 Btu/h11.43 kWat 5°F, full speed
-
LVN420HV (the pairing on screen) LG 38,500 Btu/h11.28 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| LCN429HV (the pairing on screen) | LG | 39,00011.43 | 47,00013.77 | 42,00012.31 | 83% | 1.96 | Yes | 1 |
| LVN420HV (the pairing on screen) | LG | 38,50011.28 | 47,00013.77 | 42,00012.31 | 82% | 1.88 | Yes | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 9, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read