LUU480HHV
LUU480HHV is in the certified data.
Its certified full-speed heating output at 5°F is 40,500–41,000 Btu/h11.87–12.02 kW, 78–82% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
LG · mini-split heat pump
LUU480HHV is in the certified data as of Sep 19, 2026.
- 48,000 Btu (4-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
50,00014.65NR
No 47°F rating for this pairing.
30,8009.03NR at 17°F
40,50011.87NR at 5°F
Btu/hkW, certified
2.25NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 50,000 Btu/h14.65 kW of heat at 47°F, 30,800 Btu/h9.03 kW at 17°F, and 40,500 Btu/h11.87 kW at 5°F, 81% of its 47°F rating. It delivers 46,000 Btu/h13.48 kW of cooling at 95°F. At 5°F that is 1,500 Btu/h0.44 kW short of the example heating load of 42,000 Btu/h12.31 kW; at 95°F it is 25,000 Btu/h7.33 kW above the example cooling load of 21,000 Btu/h6.15 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,750 sq ft where winters reach 5°F: heating runs from 42,000 Btu/h12.31 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 21,000 Btu/h6.15 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 205788777 · listed by LG · certified Mar 9, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 40,50011.87 kW | −4% | 2.25 | |
| 17°Ffull speed | 30,8009.03 kW | −19% | NR | |
| 47°Fnormal speed | 50,00014.65 kW | +2% | NR | |
| 95°Fcooling, full load | 46,00013.48 kW | — | NR |
EER2 11.95 in that test. SEER2 17.75 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.28kW
- Electrical input in the 95°F cooling test
- 3.85kW
- Seasonal average heating COP
- 2.75
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton mini-split models
- This pairing at 5°F
- 40,500 Btu/h11.87 kWNR
- This unit at 5°F median across its pairings
- 40,500 Btu/h11.87 kW
- Median of 4-ton mini-split models at 5°F
- 42,000 Btu/h12.31 kW
- Models in this group
- 321
This unit is above 47% of them, at number 170 of 321 by heat at 5°F. The middle half of the group runs 37,000 to 47,500 Btu/h.
Closest models by heat at 5°F
- TMFX48HEI2NAS0U25Thermoflux · 42,000 Btu/h
- H48FMHD6XPCTCL · 41,500 Btu/h
- AOUK048SSAN7Fujitsu · 41,000 Btu/h
- SAK-48-CT2/220VStar Air Kontrol · 40,500 Btu/h
- KUMXB541ALG · 40,000 Btu/h
- LUU480HVLG · 39,500 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for LUU480HHV
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 50,000 Btu/h14.65 kWNR | 50,000–52,000 Btu/h14.65–15.24 kW |
| Heat output at 17°F full speed | 30,800 Btu/h9.03 kWNR | 30,800–32,600 Btu/h9.03–9.55 kW |
| Heat output at 5°F full speed | 40,500 Btu/h11.87 kWNR | 40,500–41,000 Btu/h11.87–12.02 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 81%NR | |
| COP at 5°F full speed | 2.25NR | 2.07–2.25 |
| HSPF2 Region IV | 9.4NR | 9.4–10.7 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 46,000 Btu/h13.48 kWNR | 46,000–48,000 Btu/h13.48–14.07 kW |
| EER2 at 95°F | 11.95NR | 11.7–12.5 |
| SEER2 cooling season | 17.75NR | 17.5–17.75 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | LVN480HV | 3 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | Canada | Canada |
| Model string as certified | LUU480HHV | |
Pairings, by indoor-unit class
3 indoor units · 3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 3 indoor units
-
LCN489HV (the pairing on screen) LG 40,500 Btu/h11.87 kWat 5°F, full speed
-
LHN488HV (the pairing on screen) LG 41,000 Btu/h12.02 kWat 5°F, full speed
-
LVN480HV (the pairing on screen) LG 40,500 Btu/h11.87 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| LCN489HV (the pairing on screen) | LG | 40,50011.87 | 52,00015.24 | 48,00014.07 | 78% | 2.20 | Yes | 1 |
| LHN488HV (the pairing on screen) | LG | 41,00012.02 | 50,00014.65 | 46,00013.48 | 82% | 2.07 | Yes | 1 |
| LVN480HV (the pairing on screen) | LG | 40,50011.87 | 50,00014.65 | 46,00013.48 | 81% | 2.25 | Yes | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 9, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read